색 시표와 색 필터를 이용한 새로운 사위검사의 신뢰도

Repeatability of New Phoria Test Using Color Chart and Color Filter

  • 이선행 (김해대학 안경광학과) ;
  • 박선영 (Vision Institutes of Song and Associates) ;
  • 김상엽 (강원대학교 안경광학과) ;
  • 이동열 (대구과학대학 안경광학과) ;
  • 김건규 (선린대학 안경광학과) ;
  • 손정식 (경운대학교 안경광학과) ;
  • 이재윤 (강원대학교 공학대학) ;
  • 조현국 (강원대학교 안경광학과)
  • Lee, Sun Haeng (Department of Ophthalmic Optics, Gimhae College University) ;
  • Park, Sun-Young (Vision Institute of Song and Associates) ;
  • Kim, Sang-Yoeb (Department of Optometry, Kangwon National University) ;
  • Lee, Dong-Yeol (Department of Ophthalmic Optics, Daegu Science University) ;
  • Kim, Kun-Kyu (Department of Optometry, Sunlin University) ;
  • Son, Jeong-Sik (Department of Visual Optics, Kyungwoon University) ;
  • Lee, Jae Yoon (College of Engineering, Kangwon National University) ;
  • Cho, Hyun Gug (Department of Optometry, Kangwon National University)
  • 투고 : 2010.07.23
  • 심사 : 2010.09.18
  • 발행 : 2010.09.30

초록

목적: 새로운 적청사위시표(Red-Blue phoria chart; RBP) 검사의 신뢰성을 평가하였다. 방법: 38명을 대상으로 원거리(5m), 근거리(40cm) 사위량을 측정하였다. RBP 시표 사위검사, 하웰시표 사위검사(HP), 그리고 Muscle Imbalance Measure (MIM) 시표 사위검사를 실시하고 검사에 대한 신뢰도를 서로 비교하였다. 결과: 수평 사위도는 원거리 RBP $-0.6{\pm}0.727{\Delta}$, HP $-0.87{\pm}1.051{\Delta}$, MIM $-1.50{\pm}1.346{\Delta}$, 근거리 RBP $-2.57{\pm}2.352{\Delta}$, HP $-2.80{\pm}2.411{\Delta}$, MIM $-3.84{\pm}2.603{\Delta}$로 측정되었다. 검사 신뢰도는 원거리의 경우 RBP>MIM>HP 순이었고, 근거리의 경우 MIM>RBP>HP 순으로 나타났다. 결론: RBP 검사법은 신뢰도가 높은 사위검사법으로 판명되었다.

Purpose: The repeatability of a new Red-Blue phoria chart test (Red-Blue phoria chart; RBP) was appreciated. Methods: Distance (5 m) and near (40 cm) heterophoria was measured in 38 visually normal subjects. Phoria tests using RBP, Howell phoria card (HP), and MIM card (MIM) were done and the repeatability of each phoria test was compared with one another. Results: The mean of horizontal deviations was that RBP was $-0.602{\pm}0.727{\Delta}$, HP was $-0.865{\pm}1.051{\Delta}$, and MIM was $-1.501{\pm}1.346{\Delta}$, at distance, and that RBP was $-2.566{\pm}2.352{\Delta}$, HP was $-2.804{\pm}2.411{\Delta}$, MIM was $-3.838{\pm}2.603{\Delta}$, at near. The repeatability was RBP>MIM>HP in distance tests and MIM>RBP>HP in near tests. Conclusions:RBP test is identified as a reliable phoria test having high repeatability.

키워드

참고문헌

  1. Casillas E. and Rosenfield M., "Comparison of subjective heterophoria testing with a phoropter and trial frame", Optom. Vis. Sci., 86(4):237-241(2006).
  2. Rainey B. B., Schroeder T. L., Goss D. A., and Grosvenor T. P., "Inter-examiner repeatability of heterophoria tests", Optom. Vis. Sci., 75(10):719-726(1998). https://doi.org/10.1097/00006324-199810000-00016
  3. 윤동호, 이상욱, 최억, "안과학", 일조각, 서울, pp.200-227(1990).
  4. 이규병, 전순우, 이현주, 이선행, 박원빈, 마기중, 박수봉 "여러가지 사위 측정법의 비교 분석", 대한시과학회지, 9(1):115-125(2007).
  5. Wong E. P. F., Fricke T. R., and Dinardo C., "Interexaminer repeatability of a new, modified prentice card compared with established phoria tests", Optom. Vis. Sci., 79(6):370-375(2002). https://doi.org/10.1097/00006324-200206000-00010
  6. Griffin J. R. and Grisham J. D., "Binocular Anomalies: Diagnosis and Vision Therapy", 4th Ed., Butterworth-Heinemann, Boston, pp. 78-85(1995).
  7. Scobee R. G. and Green E. L., "Test for heterophoria: reliability of tests, comparisons between tests, and effect of changing testing conditions", Transactions of the American Academy of Ophthalmology & Otolaryngology, 51: 179-197(1947).
  8. Bland J. M. and Altman D. G., "Statistical methods for assessing agreement between two methods of clinical measurement", Lancet, 8:307-310(1986).
  9. Elliott D. B., "Clinical procedures in primary eye care", 3rd ed., Butterworth-Heinemann, Philadelphia, pp. 169-174(2007).
  10. Schroeder T. L., Rainey B. B., Goss D. A., and Grosvenor T. P., "Reliability of and comparisons among methods of measuring dissociated phoria", Optom. Vis. Sci., 73:389-397(1996). https://doi.org/10.1097/00006324-199606000-00006
  11. Hirsch M. J. and Bing L. B., "The effect of testing method on values obtained for phoria at forty centimeters", Am. J. Optom. Arch. Am. Acad. Optom., 25:407-416(1948). https://doi.org/10.1097/00006324-194809000-00001
  12. Krger R. H. and Binder S., "Use of paper selectively absorbing long wavelengths to reduce the impact of educational near work on human refractive development", Br. J. Ophthalmol., 84:890-893(2000). https://doi.org/10.1136/bjo.84.8.890