DOI QR코드

DOI QR Code

Radiation Exposure to Physicians During Interventional Pain Procedures

  • Kim, Tae-Wan (Department of Anesthesiology and Pain Medicine, Yonsei University College of Medicine) ;
  • Jung, Jang-Hwan (Department of Anesthesiology and Pain Medicine, Yonsei University College of Medicine) ;
  • Jeon, Hyun-Joo (Department of Anesthesiology and Pain Medicine, Yonsei University College of Medicine) ;
  • Yoon, Kyung-Bong (Department of Anesthesiology and Pain Medicine, Yonsei University College of Medicine) ;
  • Yoon, Duck-Mi (Department of Anesthesiology and Pain Medicine, Yonsei University College of Medicine)
  • Received : 2009.08.19
  • Accepted : 2009.12.07
  • Published : 2010.03.01

Abstract

Background: Fluoroscopy has been an integral part of modern interventional pain management. Yet fluoroscopy can be associated with risks for the patients and clinicians unless it is managed with appropriate understanding, skill and vigilance. Therefore, this study was designed to determine the amount of radiation received by a primary operator and an assistant during interventional pain procedures that involve the use of fluoroscopy. Methods: In order to examine the amount of radiation, the physicians were monitored by having them wear three thermoluminescent badges during each single procedure, with one under a lead apron, one under the apron collar and one on the leg during each single procedure. The data obtained from each thermoluminescent badge was reviewed from September 2008 to November 2008 and the annual radiation exposure was subsequently calculated. Results: A total of 505 interventional procedures were performed with C-arm fluoroscopy during three months. The results of this study revealed that the annual radiation exposure was relatively low for both the operator and assistant. Conclusions: With proper precautions, the use of fluoroscopy during interventional pain procedures is a safe practice.

Keywords

References

  1. Shope TB. Radiation-induced skin injuries from fluoroscopy. Radiographics 1996; 16: 1195-9. https://doi.org/10.1148/radiographics.16.5.8888398
  2. Valentin J. Avoidance of radiation injuries from medical interventional procedures. Ann ICRP 2000; 30: 7-67.
  3. Fishman SM, Smith H, Meleger A, Seibert JA. Radiation safety in pain medicine. Reg Anesth Pain Med 2002; 27: 296- 305.
  4. Manchikanti L, Cash KA, Moss TL, Pampati V. Radiation exposure to the physician in interventional pain management. Pain Physician 2002; 5: 385-93.
  5. Botwin KP, Thomas S, Gruber RD, Torres FM, Bouchlas CC, Rittenberg JJ, et al. Radiation exposure of the spinal interventionalist performing fluoroscopically guided lumbar transforaminal epidural steroid injections. Arch Phys Med Rehabil 2002; 83: 697-701. https://doi.org/10.1053/apmr.2002.32439
  6. Zhou Y, Singh N, Abdi S, Wu J, Crawford J, Furgang FA. Fluoroscopy radiation safety for spine interventional pain procedures in university teaching hospitals. Pain Physician 2005; 8: 49-53.
  7. Mahesh M. Fluoroscopy: patient radiation exposure issues. Radiographics 2001; 21: 1033-45. https://doi.org/10.1148/radiographics.21.4.g01jl271033
  8. Hororio TB. Fluoroscopy and radiation safety. In: Essentials of pain medicine and regional anesthesia. 2nd ed. Edited by Honorio TB, Srinivasa R, Robert EM, Spencer SL, Scott MF. Philadelphia, Churchill Livingstone Publishers. 2005, pp 516-24.
  9. Botwin KP, Freeman ED, Gruber RD, Torres-Rames FM, Bouchtas CG, Sanelli JT, et al. Radiation exposure to the physician performing fluoroscopically guided caudal epidural steroid injections. Pain Physician 2001; 4: 343-8.
  10. Botwin KP, Fuoco GS, Torres FM, Gruber RD, Bouchlas CC, Castellanos R, et al. Radiation exposure to the spinal interventionalist performing lumbar discography. Pain Physician 2003; 6: 295-300.

Cited by

  1. A Study to Compare the Radiation Absorbed Dose of the C-arm Fluoroscopic Modes vol.24, pp.4, 2011, https://doi.org/10.3344/kjp.2011.24.4.199
  2. Radiation safety for anaesthetists vol.13, pp.2, 2013, https://doi.org/10.1093/bjaceaccp/mks055
  3. The Survey about the Degree of Damage of Radiation-Protective Shields in Operation Room vol.26, pp.2, 2013, https://doi.org/10.3344/kjp.2013.26.2.142
  4. Coaching Reduced the Radiation Dose of Pain Physicians by Half during Interventional Procedures vol.15, pp.5, 2014, https://doi.org/10.1111/papr.12251
  5. Radiation Exposure in Interventional Pain Management: We Still Have Much to Learn vol.15, pp.5, 2015, https://doi.org/10.1111/papr.12290
  6. Intravenous Acetaminophen vol.5, pp.4, 2017, https://doi.org/10.1007/s40138-017-0142-5
  7. Radiation dose to the operator during fluoroscopically guided spine procedures vol.59, pp.9, 2017, https://doi.org/10.1007/s00234-017-1868-1
  8. Radiation safety: a focus on lead aprons and thyroid shields in interventional pain management vol.31, pp.4, 2018, https://doi.org/10.3344/kjp.2018.31.4.244
  9. Use of a radiopaque localizer grid to reduce radiation exposure vol.5, pp.1, 2011, https://doi.org/10.1186/1750-1164-5-6
  10. Evaluation of A Better Approach for Open Reduction Of Severe Gartland Type III Supracondylar Humeral Fracture vol.34, pp.5, 2010, https://doi.org/10.1080/08941939.2019.1649766