DOI QR코드

DOI QR Code

Integrated vibration control and health monitoring of building structures: a time-domain approach

  • Chen, B. (Department of Civil and Structural Engineering, The Hong Kong Polytechnic University) ;
  • Xu, Y.L. (Department of Civil and Structural Engineering, The Hong Kong Polytechnic University) ;
  • Zhao, X. (Department of Civil and Structural Engineering, The Hong Kong Polytechnic University)
  • 투고 : 2008.08.12
  • 심사 : 2009.11.17
  • 발행 : 2010.09.25

초록

Vibration control and health monitoring of building structures have been actively investigated in recent years but treated separately according to the primary objective pursued. This paper presents a general approach in the time domain for integrating vibration control and health monitoring of a building structure to accommodate various types of control devices and on-line damage detection. The concept of the time-domain approach for integrated vibration control and health monitoring is first introduced. A parameter identification scheme is then developed to identify structural stiffness parameters and update the structural analytical model. Based on the updated analytical model, vibration control of the building using semi-active friction dampers against earthquake excitation is carried out. By assuming that the building suffers certain damage after extreme event or long service and by using the previously identified original structural parameters, a damage detection scheme is finally proposed and used for damage detection. The feasibility of the proposed approach is demonstrated through detailed numerical examples and extensive parameter studies.

키워드

과제정보

연구 과제 주관 기관 : National Natural Science Foundation of China

참고문헌

  1. Aktan, A.E., Catbas, F.N., Grimmelsman, K.A. and Tsikos, C.J. (2000), "Issues in infrastructure health monitoring for management", J. Eng. Mech.-ASCE, 126(7), 711-724. https://doi.org/10.1061/(ASCE)0733-9399(2000)126:7(711)
  2. Chen, B. and Xu, Y.L. (2008), "Integrated vibration control and health monitoring of building structures using semi-active friction dampers: Part II-numerical investigation", Eng. Struct., 30(3), 573-587. https://doi.org/10.1016/j.engstruct.2007.03.006
  3. Clough, R.W. and Penzien, J. (2003), Dynamic of structures, 3rd Edition, McGraw-Hill, New York.
  4. Gattulli, V. and Romeo, F. (2000), "Integrated procedure for identification and control of MDOF structures", J. Eng. Mech.-ASCE, 126(7), 730-737. https://doi.org/10.1061/(ASCE)0733-9399(2000)126:7(730)
  5. Hac, A. and Spanos, P.D. (1990), "Time domain method for parameter system identification", J. Vib. Acoust., 112(3), 281-287. https://doi.org/10.1115/1.2930506
  6. Housner, G.W., Bergman, L.A., Caughey, T.K., Chassiakos, A.G., Claus, R.O., Masri, S.F., Skelton, R.E., Soong, T.T., Spencer, B.F. Jr. and Yao, J.T.P. (1997), "Structural control: past present, and future", J. Eng. Mech.-ASCE, 123(9), 897-971. https://doi.org/10.1061/(ASCE)0733-9399(1997)123:9(897)
  7. Koh, C.G., See, L.M. and Balendra, T. (1991), "Estimation of structural parameters in time domain: a substructure approach", Earthq. Eng. Struct. D., 20(8), 787-801. https://doi.org/10.1002/eqe.4290200806
  8. Kori, J.G. and Jangid, R.S. (2008), "Semi-active friction dampers for seismic control of structures", Smart Struct. Syst., 4(4), 493-515. https://doi.org/10.12989/sss.2008.4.4.493
  9. Loh, C.H., Lin, C.Y. and Huang, C.C. (2000), "Time domain identification of frames under earthquake loadings", J. Eng. Mech.-ASCE, 126(7), 693-703. https://doi.org/10.1061/(ASCE)0733-9399(2000)126:7(693)
  10. Ng, C.L. and Xu, Y.L. (2007), "Semi-active control of a building complex with variable friction dampers," Eng. Struct., 29(6), 1209-1225. https://doi.org/10.1016/j.engstruct.2006.08.007
  11. Ohtori, C.L., Christenson, R.E., Spencer, B.F. Jr. and Dyke, S.J. (2004), "Benchmark control problems for seismically excited nonlinear buildings", J. Eng. Mech.-ASCE, 130(4), 366-385. https://doi.org/10.1061/(ASCE)0733-9399(2004)130:4(366)
  12. Ray, L.R. and Tian, L. (1999), "Damage detection in smart structures through sensitivity enhancing feedback control", J. Sound Vib., 227(5), 987-1002. https://doi.org/10.1006/jsvi.1999.2392
  13. Shinozuka, M., Yun, C.B. and Imai, H. (1982), "Identification of linear structural dynamic system", J. Eng. Mech. Div., ASCE, 108(6), 1371-1390.
  14. Skelton, R.E. (1988), Dynamic system control: Linear systems analysis and synthesis, Wiley, New York.
  15. Spencer, B.F. Jr. and Nagarajaiah, S. (2003), "State of the art of structural control", J. Struct. Eng.-ASCE, 129(7), 845-856. https://doi.org/10.1061/(ASCE)0733-9445(2003)129:7(845)
  16. Stengel, R.F. (1986), Stochastic optimal control: Theory and application, Wiley, New York.
  17. Sun, D.C. and Tong, L.Y. (2003), "Closed-loop based detection of debonding of piezoelectric actuator patches in controlled beams", Int. J. Solids Struct., 40(10), 2449-2471. https://doi.org/10.1016/S0020-7683(03)00080-5
  18. Wang, D. and Haldar, A. (1994), "Element-level system identification with unknown input", J. Eng. Mech.-ASCE, 120(1), 159-176. https://doi.org/10.1061/(ASCE)0733-9399(1994)120:1(159)
  19. Wong, K.Y., Chan, K.W.Y., Man, K.L., Mak, W.P.N. and Lau, C.K. (2000), "The use of structural health monitoring system in operation and maintenance of cable-supported bridges", Proceedings of the Structural Symposium 2000-Highway and Railway Structures, Hong Kong, China.
  20. Xu, Y.L. and Chen, B. (2008), "Integrated vibration control and health monitoring of building structures using semi-active friction dampers: Part I-methodology", Eng. Struct., 30(7), 1789-1801. https://doi.org/10.1016/j.engstruct.2007.11.013
  21. Xu, Y.L. and Ng, C.L. (2008), "Seismic protection of a building complex using variable friction damper: Experimental investigation", J. Eng. Mech.-ASCE, 134(8), 637-649. https://doi.org/10.1061/(ASCE)0733-9399(2008)134:8(637)
  22. Zhao, X., Xu, Y.L., Li, J. and Chen, J. (2006), "Hybrid identification method for multi-story buildings with unknown ground motion: theory", J. Sound Vib., 291(1-2), 215-239. https://doi.org/10.1016/j.jsv.2005.06.006

피인용 문헌

  1. Assessment on Time-Varying Thermal Loading of Engineering Structures Based on a New Solar Radiation Model vol.2014, 2014, https://doi.org/10.1155/2014/639867
  2. Seismic Fortification Analysis of the Guoduo Gravity Dam in Tibet, China vol.2015, 2015, https://doi.org/10.1155/2015/396124
  3. Physical parameter identification of nonlinear base-isolated buildings using seismic response data vol.145, 2014, https://doi.org/10.1016/j.compstruc.2014.08.006
  4. An On-line Integration Technique for Structural Damage Detection and Active Optimal Vibration Control vol.14, pp.05, 2014, https://doi.org/10.1142/S0219455414400033
  5. Dynamic condensation approach to calculation of structural responses and response sensitivities vol.88, 2017, https://doi.org/10.1016/j.ymssp.2016.11.025
  6. Developing a smart structure using integrated DDA/ISMP and semi-active variable stiffness device vol.18, pp.5, 2016, https://doi.org/10.12989/sss.2016.18.5.955
  7. Developing a Smart Structure Using Integrated Subspace-Based Damage Detection and Semi-Active Control vol.31, pp.11, 2016, https://doi.org/10.1111/mice.12231
  8. Application of Hilbert-Huang Transform in Structural Health Monitoring: A State-of-the-Art Review vol.2014, 2014, https://doi.org/10.1155/2014/317954
  9. Evaluation on Impact Interaction between Abutment and Steel Girder Subjected to Nonuniform Seismic Excitation vol.2015, 2015, https://doi.org/10.1155/2015/981804
  10. Structural control and health monitoring of building structures with unknown ground excitations: Experimental investigation vol.390, 2017, https://doi.org/10.1016/j.jsv.2016.11.035
  11. Decreasing the damage in smart structures using integrated online DDA/ISMP and semi-active control vol.21, pp.10, 2012, https://doi.org/10.1088/0964-1726/21/10/105017
  12. Structural Monitoring of Metro Infrastructure during Shield Tunneling Construction vol.2014, 2014, https://doi.org/10.1155/2014/784690
  13. Piezoelectric and dielectric properties of PZT–cement–aluminum nano-composites vol.41, pp.1, 2015, https://doi.org/10.1016/j.ceramint.2014.05.136
  14. A Comparative Study on Frequency Sensitivity of a Transmission Tower vol.2015, 2015, https://doi.org/10.1155/2015/610416
  15. Integration of health monitoring and vibration control for smart building structures with time-varying structural parameters and unknown excitations vol.15, pp.3, 2015, https://doi.org/10.12989/sss.2015.15.3.807
  16. Synthesis of vibration control and health monitoring of building structures under unknown excitation vol.23, pp.10, 2014, https://doi.org/10.1088/0964-1726/23/10/105025
  17. Damage Detection on Sudden Stiffness Reduction Based on Discrete Wavelet Transform vol.2014, 2014, https://doi.org/10.1155/2014/807620
  18. Free-Interface Modal Synthesis Based Substructural Damage Detection Method vol.2014, 2014, https://doi.org/10.1155/2014/741697
  19. Establishment and Application of the Wind and Structural Health Monitoring System for the Runyang Yangtze River Bridge vol.2014, 2014, https://doi.org/10.1155/2014/421038
  20. Performance Assessment on the Plastic Mortar Culvert Reinforced by Glass Fiber vol.256-259, pp.1662-7482, 2012, https://doi.org/10.4028/www.scientific.net/AMM.256-259.565
  21. Performance Evaluation of a Transmission Tower Subjected to Base Settlement vol.744-746, pp.1662-7482, 2015, https://doi.org/10.4028/www.scientific.net/AMM.744-746.361
  22. Vibration-Based Damage Identification and Condition Monitoring of Metro Trains: Warsaw Metro Case Study vol.2018, pp.1875-9203, 2018, https://doi.org/10.1155/2018/8475684
  23. Ambient vibration tests on a 19 - story asymmetric steel building vol.40, pp.1, 2011, https://doi.org/10.12989/sem.2011.40.1.001
  24. Instrumentation and system identification of a typical school building in Istanbul vol.43, pp.2, 2010, https://doi.org/10.12989/sem.2012.43.2.179
  25. A Review on Adaptive Methods for Structural Control vol.10, pp.None, 2016, https://doi.org/10.2174/1874149501610010653
  26. On-line integration of structural identification/damage detection and structural reliability evaluation of stochastic building structures vol.63, pp.6, 2017, https://doi.org/10.12989/sem.2017.63.6.789
  27. Setting the problem of designing monitoring systems for engineering structures and methods of its solution vol.164, pp.None, 2020, https://doi.org/10.1051/e3sconf/202016402026
  28. On‐line system identification of structures using wavelet‐Hilbert transform and sparse component analysis vol.35, pp.8, 2010, https://doi.org/10.1111/mice.12552
  29. Integration of identification and vibration control of time-varying structures subject to unknown seismic ground excitation vol.26, pp.15, 2010, https://doi.org/10.1177/1077546319896444
  30. A general synthesis of identification and vibration control of building structures under unknown excitations vol.143, pp.None, 2010, https://doi.org/10.1016/j.ymssp.2020.106803
  31. Simultaneous Online Damage Detection and Vibration Control of Structures Using Synchronization and Semi-Active Control vol.21, pp.3, 2021, https://doi.org/10.1142/s0219455421500383
  32. A two-step interval structural damage identification approach based on model updating and set-membership technique vol.182, pp.None, 2010, https://doi.org/10.1016/j.measurement.2021.109464
  33. Integrating structural control, health monitoring, and energy harvesting for smart cities vol.38, pp.8, 2021, https://doi.org/10.1111/exsy.12845