References
- Bakar, A.A., Din, M.M., Yussof, S., Ghapar, A.A., Rusli, M.E. and Chang G.C. (2007), "Using wireless sensor networks for detecting leakage in water pipes", Proceedings of the ACRS 2007, Asian Association on Remote Sensing (AARS), Kuala Lumpur, Malaysia, November.
- Chen, C. and Chou P.H. (2008), "EcoDAQ: A case study of a densely distributed real-time system for high data rate wireless data acquisition", Proceedings of the 14th IEEE International Conference on Embedded and Real-Time Computing Systems and Applications (RTCSA), Kaohsiung, Taiwan, August. J FLUID ENG-T ASME.
- Chen, M.H. (2008), TeleScribe: a scalable resumable mass reprogramming approach, Master's thesis, National Tsing Hua University.
- Chou, P.H. (2010), Eco: Ultra-compact wireless sensing system, http://www.ecomote.net/.
- Cooley, J.W. and Tukey, J.W. (1965), "An algorithm for the machine calculation of complex fourier series", Math. Comput., 19(90), 297-301. https://doi.org/10.1090/S0025-5718-1965-0178586-1
- Evans, R.P., Blotter, J.D. and Stephens, A.G. (2004), "Flow rate measurements using flow-induced pipe vibration", J. Fluid. Eng., 126(2), 280-285. https://doi.org/10.1115/1.1667882
- Ferrante, M. and Brunone, B. (2003), "Pipe system diagnosis and leak detection by unsteady-state tests. 1. harmonic analysis", Adv. Water Resour., 26(1), 95-105. https://doi.org/10.1016/S0309-1708(02)00101-X
- Furness, R.A. and Reet, J.D. (1998), Pipe line leak detection techniques, Pipe line rules of thumb handbook (Ed. E.W. McAllister), Gulf Professional Publishing, USA.
- Gao, Y., Brennan, M.J., Joseph, P.F., Muggleton, J.M. and Hunaidi, O. (2005), "On the selection of acoustic/ vibration sensors for leak detection in plastic water pipes", J. Sound Vib., 283(3-5), 927-941. https://doi.org/10.1016/j.jsv.2004.05.004
- HAESTAD Press (2003), HAMMER user's guide, http://www.haestad.com.
- Hunaidi, O. and Chu, W.T. (1999), "Acoustical characteristics of leak signals in plastic water distribution pipes", J. Appl. Acoust., 58, 235-254. https://doi.org/10.1016/S0003-682X(99)00013-4
- Jin, Y. and Eydgahi, A. (2008), "Monitoring of distributed pipeline systems by wireless sensor networks", Proceedings of the 2008 IAJC-IJME International Conference.
- Liggett, J.A. and Chen L.C. (1994), "Inverse transient analysis in pipe networks", J. Hydraul. Eng.-ASCE, 120(8), 934-955. https://doi.org/10.1061/(ASCE)0733-9429(1994)120:8(934)
- Liou, C.P. and Tian J. (1995), "Leak detection: transient flow simulation approach", J. Energ. Resour. Technol., 117(3), 243-248. https://doi.org/10.1115/1.2835348
- Park, C. and Chou, P.H. (2006), "Eco: ultra-wearable and expandable wireless sensor platform", Proceedings of the Third International Workshop on Body Sensor Networks, MIT Media Lab, April.
- Shinozuka, M., Chou, P.H., Kim, S., Kim, H.R., Yoon, E., Mustafa, H., Karmakar, D. and Pul, S. (2010), "Nondestructive monitoring of a pipe network using a MEMS-based wireless network", Proceedings of the SPIE Conference on Smart Structures & Materials/NDE, San Diego, CA.
- Shinozuka, M. and Dong, X. (2005), "Evaluation of hydraulic transients and damage detection in water system under a disaster event", Proceedings of the 3rd US-Japan Workshop on Water System Seismic Practices, Kobe, Japan, January.
- Stoianov, I., Maksimovic, C. and Graham, N.J.D. (2003), "Designing a continuous monitoring system for transmission Pipelines", Proceedings of the CCWI 2003, Advances in Water Supply Management Conference, London, UK.
- Stoianov, I., Nachman, L. and Madden, S. (2007), "PIPENET: A wireless sensor network for pipeline monitoring", Proceedings of the 6th International Conference on Information Processing in Sensor Networks, Cambridge, Massachusetts, USA, April.
- Stoianov, I., Nachman, L., Whittle, A., Madden, S. and Kling, R. (2006), "Sensor networks for monitoring water supply and sewer systems: Lessons from Boston", Proceedings of the 8th Annual Water Distribution Systems Analysis Symposium.
- Wang, X.J., Lambert, M.F., Simpson, A.R., Liggett, J.A. and Vitkovsky, J.P. (2002), "Leak detection in pipelines using the damping of fluid transients", J. Hydraul. Eng.-ASCE, 128(7), 697-711. https://doi.org/10.1061/(ASCE)0733-9429(2002)128:7(697)
- Yoo, S.M., Chen, C.J. and Chou, P.H. (2009), "Low-complexity, high-throughput multiple-access wireless protocol for body area networks", Proceedings of the Body Sensor Networks, Berkeley, CA, USA, June.
Cited by
- Long term monitoring of a cable stayed bridge using DuraMote vol.11, pp.5, 2013, https://doi.org/10.12989/sss.2013.11.5.453
- Sparse representation of ultrasonic guided-waves for robust damage detection in pipelines under varying environmental and operational conditions vol.23, pp.2, 2016, https://doi.org/10.1002/stc.1776
- A digital output accelerometer using MEMS-based piezoelectric accelerometers and arrayed CMOS inverters with satellite capacitors vol.20, pp.6, 2011, https://doi.org/10.1088/0964-1726/20/6/065017
- Real-time remote monitoring: the DuraMote platform and experiments towards future, advanced, large-scale SCADA systems vol.11, pp.4, 2015, https://doi.org/10.1080/15732479.2014.951861
- Novel vibration-based technique for detecting water pipeline leakage vol.13, pp.6, 2017, https://doi.org/10.1080/15732479.2016.1188318
- Bayesian forecasting approach for structure response prediction and load effect separation of a revolving auditorium vol.24, pp.4, 2010, https://doi.org/10.12989/sss.2019.24.4.507
- Linear Prediction for Leak Detection in Water Distribution Networks vol.11, pp.1, 2010, https://doi.org/10.1061/(asce)ps.1949-1204.0000415
- Sustainability Analysis of a Leakage-Monitoring Technique for Water Pipeline Networks vol.11, pp.1, 2020, https://doi.org/10.1061/(asce)ps.1949-1204.0000425
- 배관 체계 자율 복구 알고리즘 비교, 분석 및 고찰 vol.36, pp.4, 2010, https://doi.org/10.14346/jkosos.2021.36.4.1