Abstract
The effect of vortex generators to manipulate the separated flow region behind the vertical fence was experimentally investigated. The experiments were performed in the circulating water channel. The parameters used in this study were the distance between the fence and vortex generators and size of vortex generators. Digital PIV method was applied to measure the instantaneous velocity fields around the fence. And the obtained flow properties were compared with those of fence How without the vortex generators. The obtained results quantitatively shows the specific size and distance of vortex generators which were effective to reduce the mean reattachment length of separation bubble behind the fence.