초록
In this paper, 2-axis driving mechanism, which uses voice coil motor (VCM), is proposed to measure the friction force. The proposed VCM actuator consists of two parts; structural part and magnetic circuit part. Structural part is simplified to perform the friction experiments. Magnetic circuit part is composed of two parts. The experiments are accomplished by changing the mass of moving part. Through the experiments, optimal dimension is selected. Finally, the experimental results are verified and the optimal case is applied to the 2-axis driving mechanism, optical image stabilization actuator.