DOI QR코드

DOI QR Code

Liquid Chromatographic Resolution of Tocainide and Its Analogues on a Doubly Tethered Chiral Stationary Phase Based on (+)-(18-Crown-6)-2,3,11,12-tetracarboxylic Acid

  • Kim, Hee-Jin (Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University) ;
  • Choi, Hee-Jung (Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University) ;
  • Hyun, Myung-Ho (Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University)
  • Published : 2010.03.20

Abstract

A doubly tethered chiral stationary phase (CSP) based on (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid were applied to the liquid chromatographic resolution of racemic tocainide, an antiarrhythmic agent, and its analogues. The chiral recognition efficiency of the doubly tethered CSP for tocainide and its analogues was generally greater than that of the corresponding singly tethered CSP especially in terms of the resolution ($R_S$). The resolution of tocainide and its analogues on the doubly tethered CSP were dependent on the content and the type of the organic and acidic modifiers in aqueous mobile phase and the column temperature. Especially, the retention behaviors of analytes on the doubly tethered CSP with the variation of the content of organic modifier in aqueous mobile phase were opposite to those on the corresponding singly tethered CSP and these opposite retention behaviors were rationalized by the lipophilicity differences of the two CSPs.

Keywords

References

  1. Roden, D. M.; Woosley, R. L. New Eng. J. Med. 1986, 315, 41. https://doi.org/10.1056/NEJM198607033150107
  2. Jamali, F.; Mehvar, R.; Pasutto, F. M. J. Pharm. Sci. 1989, 78, 695. https://doi.org/10.1002/jps.2600780902
  3. Ahuja, S. Chiral Separations by Chromatography; AmericanChemical Society, Washington, D.C., Oxford University Press:Oxford, 2000.
  4. Subramanian G., Ed., Chiral Separation techniques: A Practical Approach, Third Completely Revised and Updated Edition; Wiley-VCH: Weinheim, 2007.
  5. Hyun, M. H.; Kim,S. N.; Choi, H. J. Bull. Kor. Chem. Soc. 2007, 28, 2531. https://doi.org/10.5012/bkcs.2007.28.12.2531
  6. Choi, H.J.; Kim, Y. K.; Hyun, M. H. Bull. Kor. Chem. Soc. 2008, 29, 1850. https://doi.org/10.5012/bkcs.2008.29.9.1850
  7. Cho, H. S.; Ha, H. J.; Choi, H. J.; Jin, J. S.; Hyun, M. H. Bull.Kor. Chem. Soc. 2008, 29, 2135. https://doi.org/10.5012/bkcs.2008.29.11.2135
  8. Schill, G.; Wainer, I. W.; Barkan, S. A. J. Liq. Chromatogr. 1986,9, 641. https://doi.org/10.1080/01483918608076658
  9. Marle, I.; Erlandsson, P.; Hansson, L.; Isaksson, R.; Pettersson, C.;Pettersson, G. J. Chromatogr. 1991, 586, 233. https://doi.org/10.1016/0021-9673(91)85127-2
  10. Andersson, S.; Allenmark, S.; Moller, P.; Persson, B.; Sanchez, D.J. Chomatogr. A 1996, 741, 23. https://doi.org/10.1016/0021-9673(96)00153-7
  11. Hyun, M. H. Bull. Kor. Chem. Soc. 2005, 26, 1153. https://doi.org/10.5012/bkcs.2005.26.8.1153
  12. Choi, H.J.; Hyun, M. H. J. Liq. Chromatogr. Rel. Technol. 2007, 30, 853. https://doi.org/10.1080/10826070701191136
  13. Hyun, M. H.; Jin, J. S.; Lee, W. J. Chromatogra. A 1998, 822, 155. https://doi.org/10.1016/S0021-9673(98)00606-2
  14. Hyun, M. H.; Cho, Y. J.; Jin, J. S. J. Sep. Sci. 2002, 25, 648. https://doi.org/10.1002/1615-9314(20020701)25:10/11<648::AID-JSSC648>3.0.CO;2-D
  15. Lee, S. J.; Cho, H. S.; Choi, H. J.; Hyun, M. H. J. Chromatogr. A2008, 1188, 318. https://doi.org/10.1016/j.chroma.2008.02.102
  16. Hyun, M. H.; Jin, J. S.; Koo, H. J.; Lee, W. J. Chromatogr. A 1999,837, 75. https://doi.org/10.1016/S0021-9673(99)00100-4
  17. Hyun, M. H.; Han, S. C.; Koo, H. J.; Lee, W. Chromatographia2000, 52, 473. https://doi.org/10.1007/BF02535722
  18. Hyun, M. H.; Tan, T.; Cho, Y. J. J. Liq. Chromatogr. Rel. Technol.2004, 27, 1671. https://doi.org/10.1081/JLC-120037363
  19. Conrad, U.; Chankvetadze, B.; Scriba, G. K. E. J. Sep. Sci. 2005,28, 2275. https://doi.org/10.1002/jssc.200500193
  20. Hyun, M. H.; Min, H. J.; Cho, Y. J. Bull. J. Kor. Chem. Soc. 2003,24, 911. https://doi.org/10.5012/bkcs.2003.24.7.911
  21. Hyun, M. H.; Song, Y.; Cho, Y. J.; Kim, D. H. J. Chromatogr. A2006, 1108, 208. https://doi.org/10.1016/j.chroma.2006.01.012
  22. Hyun, M. H.; Song, Y.; Cho, Y. J.; Choi, H. J. Chirality 2008, 20,325. https://doi.org/10.1002/chir.20442
  23. Hyun, M. H.; Jin, J. S.; Han, S. C.; Cho, Y. J. Microchem. J. 2001,70, 205. https://doi.org/10.1016/S0026-265X(01)00134-5

Cited by

  1. Development of HPLC Chiral Stationary Phases Based on (+)-(18-Crown-6)-2,3,11,12-tetracarboxylic Acid and Their Applications vol.27, pp.9, 2015, https://doi.org/10.1002/chir.22484
  2. Recent applications in chiral high performance liquid chromatography: A review vol.706, pp.2, 2010, https://doi.org/10.1016/j.aca.2011.08.038
  3. Resolution of Tocainide and Its Analogues on a Doubly Tethered N-CH3 Amide Chiral Stationary Phase Based on (+)-(18-Crown-6)-2,3,11,12-tetracarboxylic Acid vol.34, pp.10, 2010, https://doi.org/10.5012/bkcs.2013.34.10.2978