PFNA and PFN in Intertrochanteric Fractures - Comparison Study of Sliding -

대퇴 전자간 골절에서 항회전 근위 대퇴 골수정과 근위 대퇴 골수정 - 활강의 비교 -

  • Choo, Suk-Kyu (Department of Orthopedic Surgery, Ilsan Paik Hospital, College of Medicine, Inje University) ;
  • Oh, Hyoung-Keun (Department of Orthopedic Surgery, Ilsan Paik Hospital, College of Medicine, Inje University) ;
  • Choi, Jun-Young (Department of Orthopedic Surgery, Ilsan Paik Hospital, College of Medicine, Inje University)
  • 주석규 (인제대학교 의과대학 일산백병원 정형외과학교실) ;
  • 오형근 (인제대학교 의과대학 일산백병원 정형외과학교실) ;
  • 최준영 (인제대학교 의과대학 일산백병원 정형외과학교실)
  • Published : 2010.03.31

Abstract

Purpose: This study compared sliding between (a) lag screws of PFN (Proximal Femoral Nail, AO synthes) and (b) the helical blade of PFNA (Proximal Femoral Nail Antirotation, AO synthes) for femoral intertrochanteric fractures. Materials and Methods: We include in our study thirty seven cases who were classified as AO/OTA type A1 femoral intertrochanteric fractures and who underwent hip operations between October 2006 and December 2008. There were 19 patients in the PFN group and 18 in the PFNA group. Degrees of sliding were also measured with postoperative radiology on last follow up compared with immediate postoperative radiology. Both groups were also compared with regard too walking ability using the method of Koval. Results: Average sliding was 5.0${\pm}$2.3 mm for lag screws of the PFN group and 2.8${\pm}$1.3 mm for the helical blade of the PFNA group. The difference was statistically significant (p=0.04). Ambulatory abilities were not statistically different (p=0.33). Conclusion: Patients in the PFNA group have less sliding of the implant, but their walking abilities are similar to patients in the PFN group.

목적: 대퇴골 전자간 골절의 치료에서 근위 대퇴 골수정(PFN)의 지연나사와 항회전 근위 대퇴 골수정의 항회전 나선 칼날의 수술 후 활강 정도를 비교하여 분석하고자 한다. 대상 및 방법: 2006년 10월부터 2008년 12월까지 대퇴골 전자간 골절 중 AO/OTA 분류 A1형으로 수술적 치료를 받은 37명의 환자를 대상으로 하였다. 이 중 PFN을 사용한 환자가 19명이었으며, PFNA를 사용한 환자가 18명이었다. 최종 추시 시에 시행한 단순 방사선 사진을 수술 직후와 비교하여 활강 정도를 측정하였으며, 임상적으로 Koval의 방법으로 수술 후 보행능력을 평가하였다. 결과: PFN의 지연나사 및 PFNA 나선 칼날의 최종 추시 시 활강 정도는 PFN군에서 평균 5.0${\pm}$2.3 mm, PFNA군에서 평균 2.8${\pm}$1.3 mm로 통계적으로 유의한 감소를 보였으며(p=0.04), 추시 기간 중 측정한 보행능력의 경우엔 두 군 간에 유의한 차이가 없었다(p=0.33). 결론: 대퇴골 전자간 골절의 치료에 있어서 수술 후 PFNA의 나선 칼날이 PFN의 지연나사보다 적은 적은 활강을 보였으나, 술 후 보행능력에 있어서는 유의한 차이가 없었다.

Keywords

References

  1. Hwang DS, Rhee KJ, Choi JH. Recovery of walking ability after treatment of unstable intertrochanteric fractures in elderly patients: comparision of compression hip screw to primary hemiarthroplasty. J Korean Hip Soc. 1999;11: 22-9.
  2. Lee JY, Lee SY. Treatment of the proximal femoral extracapsular fracture with proximal femoral nail antirotation (PFNA): comparison with proximal femoral nail (PFN). J Korean Hip Soc. 2007;19:183-9.
  3. Richmond J, Aharonoff GB, Zuckerman JD, Koval KJ. Mortality risk after hip fractures. 2003. J Orthop Trauma. 2003;17 Suppl:2-5. https://doi.org/10.1097/00005131-200309001-00002
  4. Evans EM. Trochanteric fractures: a review of 110 cases treated by nail-plate fixation. J Bone Joint Surg Br. 1951; 33:192-204.
  5. Madesen JE, Naess L, Aune AK, Alho A, Ekeland A, Stromsoe K. Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: a comparative study with the Gamma nail and compression hip screw. J Orthop Trauma. 1998; 12:241-8. https://doi.org/10.1097/00005131-199805000-00005
  6. Rha JD, Kim YH, Yoon SI, Park TS, Lee MH. Factors affecting sliding of the lag screw in intertrochanteric fractures. Int Orthop. 1993;17:320-4.
  7. Schipper IB, Marti RK, van der Werken C. Unstable trochanteric femoral fractures: extramedullary or intramedullary fixation.Review of literature. Injury. 2004;35:142-51. https://doi.org/10.1016/S0020-1383(03)00287-0
  8. Strauss E, Frank J, Lee J, Kummer FJ, Tejwani N. Helical blade versus sliding hip screw for treatment of unstable intertrochanteric hip fractures: a biomechanical evaluation. Injury. 2006;37:984-9. https://doi.org/10.1016/j.injury.2006.06.008
  9. Cleveland M, Bosworth DM, Thompson FR, Wilson HJ Jr, Ishizuka T. A ten-year analysis of intertrochanteric fractures of the femur. J Bone Joint Surg Am. 1959;41: 1399-408.
  10. Koval KJ, Skovron ML, Aharonoff GB, Meadows SE, Zuckerman JD. Ambulatory ability after hip fracture. A prospective study in geriatric patients. Clin Orthop Relat Res. 1995;310:150-9.
  11. Hardy DC, Descamps PY, Krallis P, et al. Use of an intramedullary hip-screw compared with a compression hip-screw with a plate for intertrochanteric femoral fractures. A prospective, randomized study of one hundred patients. J Bone Joint Surg Am. 1998;80:618-30.
  12. Kyle RF, Wright TM, Burmstein AH. Biomechanical analysis of the sliding characteristics of compression hip screws. J Bone Joint Surg Am. 1980;62:1308-14.
  13. Curtis MJ, Jinnah RH, Wilson V, Cunningham BW. Proximal femoral fractures: a biomechanical study to compare intramedullary and extramedullary fixation. Injury. 1994;25:99-104. https://doi.org/10.1016/0020-1383(94)90111-2
  14. Davis TR, Sher JL, Horsman A, Simpsion M, Porter BB, Checketts RG. Intertrochanteric femoral fractures. Mechanical failure after internal fixation. J Bone Joint Surg Br. 1990;72:26-31.
  15. Kim WY, Han CH, Park JI, Kim JY. Failure of intertrochanteric fracture fixation with a dynamic hip screw in relation to pre-operative fracture stability and osteoporosis. Int Orthop. 2001;25:360-2. https://doi.org/10.1007/s002640100287
  16. Lee KB, Lee BT. Complications of femoral pertrochanteric fractures treated with proximal femoral nail (PFN). J Korean Soc Fracture. 2007;20:33-9.
  17. Choo SK, Oh HK, Kim YC, Lee DB. Excessive sliding of compression hip screw for the treatment of intertrochanteric fracture in elderly. J Korean Hip Soc. 2007;19:190-6.
  18. Butt MS, Krikler SJ, Nafie S, Ali MS. Comparision of dynamic hip screw and gamma nail: a prospective, randomized, controlled trial. Injury. 1995;26:615-8. https://doi.org/10.1016/0020-1383(95)00126-T
  19. Halder SC. The Gamma nail for peritrochanteric fractures. J Bone Joint Surg Br. 1994;74:340-4.
  20. Simmermacher RKJ, Bosch AM, van der Werken C. The AO/ASIF-proximal femoral nail (PFN): a new device for the treatment of unstable proximal femoral fractures. Injury. 1999;30:327-32. https://doi.org/10.1016/S0020-1383(99)00091-1
  21. Al-yassari G, Langstaff RJ, Jone JW, Al-Lami M. The AO/ASIF proximal femoral nail (PFN) for the treatment of unstable trochanteric femoral fracture. Injury. 2002;33:395-9. https://doi.org/10.1016/S0020-1383(02)00008-6
  22. Im GI, Lee SH. Spontaneous extracorporeal extrusion of the lag screw from a proximal femoral nail. Injury Extra. 2006;37:147-50. https://doi.org/10.1016/j.injury.2005.10.030
  23. Steinberg GG, Desal SS, Konwitw NA, Sullivan TJ. The intertrochanteric hip fractures. A retrospective analysis. Orthopedics. 1988;11:265-73.
  24. Lindskog DM, Baumgaertner MR. Unstable intertrochanteric hip fractures in the elderly. J Am Acad Orthop Surg. 2004; 12:179-90.
  25. Park MS, Lim YJ, Kim YS, Kim KH, Cho HM. Treatment of proximal femoral fractures with proximal femoral nail antirotation (PFNA). J Korean Soc Fractures. 2009;22:91-7.
  26. Yoo JH, Park JS, Non KC, Chung KJ, Kim HK, Kang JK, Hwang JH. The results of proximal femoral nail antirotation: a comparative study with proximal femoral nail. J Korean Hip Soc. 2008;20:286-92.