Accuracy of the Free Hand Placement of an External Ventricular Drain (EVD)

  • Lee, Ji-Hoon (Department of Neurosurgery, Gachon University of Medicine & Science, Gil Medical Center) ;
  • Park, Cheol-Wan (Department of Neurosurgery, Gachon University of Medicine & Science, Gil Medical Center) ;
  • Lee, Uhn (Department of Neurosurgery, Gachon University of Medicine & Science, Gil Medical Center) ;
  • Kim, Young-Bo (Department of Neurosurgery, Gachon University of Medicine & Science, Gil Medical Center) ;
  • Yoo, Chan-Jong (Department of Neurosurgery, Gachon University of Medicine & Science, Gil Medical Center) ;
  • Kim, Eun-Young (Department of Neurosurgery, Gachon University of Medicine & Science, Gil Medical Center) ;
  • Kim, Jae-Myung (Department of Neurosurgery, Gachon University of Medicine & Science, Gil Medical Center) ;
  • Kim, Woo-Kyung (Department of Neurosurgery, Gachon University of Medicine & Science, Gil Medical Center)
  • 발행 : 2010.06.30

초록

Objective : Free hand insertion of an external ventricular drain (EVD) is one of the most common emergency neurosurgical procedures, usually performed on critically ill patients. Complications such as infection and hemorrhage that accompany the placement of an EVD have been studied thoroughly, but few reports have focused on the accuracy of EVD positioning. As a result, the authors of this paper retrospectively studied the accuracy of tip positioning in the placement of an EVD. Methods : One hundred and thirteen emergency EVDs were performed through Kocher' point during the past 3 years. All patients underwent the following procedures: at least one routine post-EVD computed tomographic (CT) scan that was retrospectively reviewed for accuracy of the EVD tip position, calculation of the Evan's index, and measurement of the intracranial length of the EVD. We divided the EVD tip position into 6 groups as follows:1) ipsilateral frontal horn of the lateral ventricle, 2) contralateral frontal horn of the lateral ventricle, 3) third ventricle, 4) body of the ipsilateral or contralateral lateral ventricle, 5) basal cisterns, or 6) brain parenchyma. Among the 6 groups, only the ipsilateral frontal horn group was considered to be the correct position for the EVD tip. Results : The mean age of the patients was $55.6{\pm}15.3$ years (age range, 12~90 years), and the most common indication for the EVD was supratentorial intracerebral hemorrhage (ICH) and intraventricular hemorrhage (IVH) (57.5%). Fortyfive out of a total of 113 EVDs were placed by inexperienced neurosurgical trainees, and the remaining 68 were placed by experienced practitioners. Among 113 post-EVD CT scans, 48 EVD tips (42.5%) were in the ipsilateral frontal horn of the lateral ventricle (considered to be the correct position); 22 (19.5%) were in the third ventricle, 16 (14.1%) in the body of the ipsilateral or contralateral lateral ventricle, 14 (12.4%) in the contralateral frontal horn of the lateral ventricle, 11 (9.7%) within the brain parenchyma and 2 (1.8%) in the basal cistern. The mean estimated EVD length was $57{\pm}8.4mm$. The mean length of EVDs that were positioned in the ipsilateral frontal horn was $55{\pm}4.3mm$, whereas the mean lengths of EVDs in the parenchyma and basal cistern were $64{\pm}14mm$ and $72{\pm}3.5mm$, respectively. In addition, there was no statistically significant relationship between the surgeon' experience and the accuracy of the position of the EVD tip (p > 0.05). Conclusion : Emergency free hand placement of an EVD might be an inaccurate procedure. Further multi-institutional prospective studies are required to assess the accuracy and complications of free hand insertion of EVDs in an emergency setting. Studies are also needed on the feasibility of routine use of intra-operative neuro-navigation of other guidance tools, such as ultrasonography.

키워드

참고문헌

  1. Arabi Y, Memish ZA, Balkhy HH, Francis C, Ferayan A, Al Shimemeri A, et al. Ventriculostomy-associated infection: Incidence and risk factors. Am J Infect Control 33:137-143, 2005 https://doi.org/10.1016/j.ajic.2004.11.008
  2. Arginteanu M, Abbott R, Frempong A. ISG viewing wandguided endoscopic catheter placement for treatment of posterior fossa CSF collection. Pediatr Neurosurg 27:319-324, 1997 https://doi.org/10.1159/000121277
  3. Banerjee PP, Luciano CJ, Lemole GM Jr, Charbel FT, Oh MY. Accuracy of ventriculostomy catheter placement using a headand hand-tracked high-resolution virtual reality simulator with haptic feedback. J Neurosurg 107:515-521,2007 https://doi.org/10.3171/JNS-07/09/0515
  4. Bogdahn U, Lau W, Hassel W, Gunreben G, Mertens HG, Brawanski A. Continuous-pressure controlled, external ventricular drainage for treatment of acute hydrocephalus: Evaluation of risk factors. Neurosurgery 31:898-904,1992 https://doi.org/10.1227/00006123-199211000-00011
  5. Bota DP, Lefranc F, Vilallobos HR, Brilmioulle S, Vincent JL. Ventriculostomy related infections in critically ill patients: A 6- year experience. J Neurosurg 103:468-472, 2005 https://doi.org/10.3171/jns.2005.103.3.0468
  6. Garell PC, Mirsky R, Noh MD, Loftus CM, Hitchon PW, Grady MS, et al. Posterior ventricular catheter burr-hole localizer. Technical note. J Neurosurg 89:157-160,1998 https://doi.org/10.3171/jns.1998.89.1.0157
  7. Ghajar JB. A guide for ventricular catheter placement. Technical note. J Neurosurg 63: 985-986,1985 https://doi.org/10.3171/jns.1985.63.6.0985
  8. Gomez CR. Ultrasonic ventriculostomy stylet. Neurosurgery 37:1020-1021, 1995 https://doi.org/10.1227/00006123-199511000-00027
  9. Greenberg MS. Operation and procedures in Handbook of Neurosurgery. ed 6, New York, Thieme Co., 2006, pp 620
  10. HS Min, JH Song. Accurate placement of parieto-occipital ventricular catheter using CT parameters. J Korean Neurosug Soc 29:886-890,2000
  11. Huyette DR, Turnbow BJ, Kaufman C, Vaslow DF, Whiting BB, Oh MY. Accuracy of the freehand pass technique for ventriculostomy catheter placement: Retrospective assessment using computed tomography scans. J Neurosurg 108:88-91, 2008 https://doi.org/10.3171/JNS/2008/108/01/0088
  12. Khanna RK, Rosenblum ML, Rock JP, Malik GM. Prolonged external ventricular drainage with percutaneous long-tunnel ventriculostomies. J Neurosurg 83:791-794,1995 https://doi.org/10.3171/jns.1995.83.5.0791
  13. Krotz M, Linsenmaier U, Kanz KG, Pfeifer KJ, Mutschler W, Reiser M. Evaluation of minimally invasive percutaneous CT controlled ventriculostomy in patients with severe head trauma. Eur Radiol 14:227-233,2004 https://doi.org/10.1007/s00330-003-2134-y
  14. Lollis SS, Roberts DW. Robotic catheter ventriculostomy. Feasibility, efficacy, and implication. J Neurosurg 108:269- 274,2008 https://doi.org/10.3171/JNS/2008/108/2/0269
  15. Mapstone TB, Ratcheson RA. Techniques of ventricular puncture, in Wilkins RH, Rengachary SS: Neurosurgery. New York, McGraw-Hill, Inc., 1996, vol 1, pp 179-184
  16. O'Leary AP, Kole MK, Hoover DA, Hysell SE, Thomas A, Shaffrey CI. Efficacy of the Ghajar Guide revisited: A prospective study. J Neurosurg 92:801-803,2000 https://doi.org/10.3171/jns.2000.92.5.0801
  17. Roitberg BZ, Khan N, Alp MS, Hersonskey T, Charbel FT, Ausman JI. Bedside external ventricular drain placement for the treatment of acute hydrocephalus. Br J Neurosurg 15:324- 327,2001 https://doi.org/10.1080/02688690120072478
  18. Ruchholtz S, Waydhas C, Muller A, Lewan UM, Nast-Kolb D, Euler E, et al. Percutaneous computed tomographic-controlled ventriculostomy in severe traumatic brain injury. J Trauma 45:505-511, 1998 https://doi.org/10.1097/00005373-199809000-00013