References
- Amstutz HC, Grigoris P. Metal on metal bearings in hip arthroplasty. Clin Orthop Relat Res. 1996;329 Suppl:11-34. https://doi.org/10.1097/00003086-199608001-00003
- August AC, Aldam CH, Pynsent PB. The McKee-Farrar hip arthroplasty. A long-term study. J Bone Joint Surg Br. 1986;68:520-7.
- Clarke MT, Darrah C, Stewart T, Ingham E, Fisher J, Nolan JF. Long-term clinical, radiological and histopathological follow-up of a well-fixed McKee-Farrar metal-on-metal total hip arthroplasty. J Arthroplasty. 2005;20:542-6. https://doi.org/10.1016/j.arth.2004.09.063
- Visuri T. Long-term results and survivorship of the McKee-Farrar total hip prosthesis. Arch Orthop Trauma Surg. 1987;106:368-74. https://doi.org/10.1007/BF00456872
- Amstutz HC, Beaule PE, Dorey FJ, Le Duff MJ, Campbell PA, Gruen TA. Metal-on-metal hybrid surface arthroplasty: two to six-year follow-up study. J Bone Joint Surg Am. 2004;86:28-39. https://doi.org/10.2106/00004623-200401000-00006
- Daniel J, Pynsent PB, McMinn DJ. Metal-on-metal resurfacing of the hip in patients under the age of 55 years with osteoarthritis. J Bone Joint Surg Br. 2004;86:177-84. https://doi.org/10.1302/0301-620X.86B2.14600
- Schmidt M, Weber H, Schon R. Cobalt chromium molybdenum metal combination for modular hip prostheses. Clin Orthop Relat Res. 1996;329 Suppl:35-47. https://doi.org/10.1097/00003086-199608001-00004
- McKellop H, Park SH, Chiesa R, et al. In vivo wear of three types of metal on metal hip prostheses during two decades of use. Clin Orthop Relat Res.1996;329 Suppl:128-40. https://doi.org/10.1097/00003086-199608001-00013
- Schey JA. Systems view of optimizing metal on metal bearings. Clin Orthop Relat Res. 1996;329 Suppl:115-27. https://doi.org/10.1097/00003086-199608000-00014
- Kim SY, Kyung HS, Ihn JC, Cho MR, Koo KH, Kim CY. Cementless Metasul metal-on-metal total hip arthroplasty in patients less than fifty years old. J Bone Joint Surg Am. 2004;86:2475-81. https://doi.org/10.2106/00004623-200411000-00018
- Smith SL, Dowson D, Goldsmith AA. The effect of femoral head diameter upon lubrication and wear of metal-on-metal total hip replacements. Proc Inst Mech Eng H. 2001;215:161-70.
- Silva M, Heisel C, Schmalzried TP. Metal-on-metal total hip replacement. Clin Orthop Relat Res. 2006;430:53-61.
- Sieber HP, Rieker CB, Ko ttig P. Analysis of 118 second-generation meta-on-metal retrieved hip implants. J Bone Joint Surg Br. 1999;81:46-50. https://doi.org/10.1302/0301-620X.81B1.9047
- Dorr LD, Wan Z, Longjohn DB, Dubois B, Murken R. Total hip arthroplasty with use of the Metasul metal-on-metal articulation. Four to seven-year results. J Bone Joint Surg Am. 2000;82;789-98. https://doi.org/10.2106/00004623-200006000-00005
- Grubl A, Marker M, Brodner W, et al. Long-term follow-up of metal-on-metal total hip replacement. J Orthop Res. 2007;25:841-8. https://doi.org/10.1002/jor.20381
- Jacobs JJ, Skipor AK, Patterson LM, et al. Metal release in patients who have had a primary total hip arthroplasty. A prospective, controlled, longitudinal study. J Bone Joint Surg Am. 1998;80:1447-58. https://doi.org/10.2106/00004623-199810000-00006
- Brodner W, Bitzan P, Meisinger V, Kaider A, Gottsauner-Wolf F, Kotz R. Serum cobalt levels after metal-on-metal total hip arthroplasty. J Bone Joint Surg Am. 2003;85:2168-73. https://doi.org/10.2106/00004623-200311000-00017
- Savarino L, Greco M, Cenni E, et al. Differences in ion release after ceramic-on-ceramic and metal-on-metal total hip replacement. Medium-term follow-up. J Bone Joint Surg Br. 2006;88:472-6. https://doi.org/10.2106/JBJS.E.00003
- Daniel J, Ziaee H, Pradhan C, Pynsent PB, McMinn DJ. Renal clearance of cobalt in relation to the use of metalon-metal bearings in hip arthroplasty. J Bone Joint Surg Am. 2010;92:840-5. https://doi.org/10.2106/JBJS.H.01821
- Gillespie WJ, Henry DA, O'Connell DL, et al. Development of hematopoietic cancers after implantation of total joint replacement. Clin Orthop Relat Res. 1996;329 Suppl:290-6. https://doi.org/10.1097/00003086-199608001-00026
- Visuri T, Pukkala E, Paavolainen P, Pulkkinen P, Riska EB. Cancer risk after metal on metal and polyethylene on metal total hip arthroplasty. Clin Orthop Relat Res. 1996;329 Suppl:280-9. https://doi.org/10.1097/00003086-199608001-00025
- Tharani R, Dorey FJ, Schmalzried TP. The risk of cancer following total hip or knee arthroplasty. J Bone Joint Surg Am. 2001;83:774-80. https://doi.org/10.2106/00004623-200105000-00019
- Ladon D, Doherty A, Newson R, Turner J, Bhamra M, Case CP. Changes in metal levels and chromosome aberrations in the peripheral blood of patients after metalon-metal hip arthroplasty. J Arthroplasty. 2004;19 Suppl:78-83.
- Dunstan E, Ladon D, Whittingham-Jones P, Carrington R, Briggs TW. Chromosomal aberrations in the peripheral blood of patients with metal-on-metal hip bearings. J Bone Joint Surg Am. 2008;90:517-22. https://doi.org/10.2106/JBJS.F.01435
- Hur CI, Yoon TR, Cho SG, Song EK, Seon JK. Serum ion level after metal-on-metal THA in patients with renal failure. Clin Orthop Relat Res. 2008;446:696-9.
- Ziaee H, Daniel J, Datta AK, Blunt S, McMinn DJ. Transplacental transfer of cobalt and chromium in patients with metal-on-metal hip arthroplasty: a controlled study. J Bone Joint Surg Br. 2007;89:301-5. https://doi.org/10.2106/JBJS.F.00491
- Rieker CB, Schon R, Kottig P. Development and validation of a second-generation metal-on-metal bearing: laboratory studies and analysis of retrievals. J Arthroplasty. 2004;19 Suppl:5-11.
- Willert HG, Buchhorn GH, Fayyazi A, et al. Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study. J Bone Joint Surg Am. 2005;87:28-36.
- Davies AP, Willert HG, Campbell PA, Learmonth ID, Case CP. An unusual lymphocytic perivascular infiltration in tissues around contemporary metal-on-metal joint replacements. J Bone Joint Surg Am. 2005;87:18-27. https://doi.org/10.2106/JBJS.C.00949
- Park YS, Moon YW, Lim SJ, Yang JM, Ahn G, Choi YL. Early osteolysis following second-generation metal-on-metal hip replacement. J Bone Joint Surg Am. 2005;87:1515-21. https://doi.org/10.2106/JBJS.D.02641
- Milosev I, Trebse R, Kovac S, Cor A, Pisot V. Survivorship and retrieval analysis of Sikomet metal-on-metal total hip replacements at a mean of seven years. J Bone Joint Surg Am. 2006;88:1173-82. https://doi.org/10.2106/JBJS.E.00604
- Korovessis P, Petsinis G, Repanti M, Repantis T. Metallosis after contemporary metal-on-metal total hip arthroplasty. Five to nine-year follow-up. J Bone Joint Surg Am. 2006;88:1183-91. https://doi.org/10.2106/JBJS.D.02916
- Pandit H, Glyn-Jones S, McLardy-Smith P, et al. Pseudotumours associated with metal-on-metal hip resurfacings. J Bone Joint Surg Br. 2008;90:847-51. https://doi.org/10.1302/0301-620X.90B7.20213