DOI QR코드

DOI QR Code

Reduction of Refrigerant-induced Noise of the Refrigerator by Modification of the Evaporator Inlet Pipe

증발기 입구 배관의 구조 개선을 통한 냉장고 냉매 소음 저감

  • Published : 2009.10.20

Abstract

This research is focused on the experimental study of the noise induced by two-phase refrigerant flow in the evaporator. The two-phase flow in the evaporator has various flow patterns. The effects of two-phase flow pattern's characteristics on the noise of the evaporator are investigated experimentally. The experimental data shows that the generated noise is mainly related to the layout of the pipe and the certain two-phase flow patterns such as the churn and slug flow. Based on these results, we removed the unnecessary vertical pipe and changed the pipe diameter of the evaporator - inlet into small one in order to avoid the intermittent flow condition. The noise level of newly-designed inlet-pipe of the evaporator was measured experimentally by refrigerant-supplying equipment and compared with that of conventional one.

Keywords

References

  1. Baker, 1954, “Design of Pipe Lines for Simultaneous Flow of Oil and Sas,” Oil and Gas Journal, Vol. 53, pp.185-190
  2. Hashizume, K., 1983, “Flow Pattern and Void Fraction of Refrigerant Two-phase Flow in a Horizontal Tube,” Bulletin of the JSME, Vol. 26, pp. 1597-1602 https://doi.org/10.1299/jsme1958.26.1597
  3. Taitel, Y. and Dukler, A. E., 1976, “A Model for Predicting Flow Regime Transitions in Horizontal and Near Horizontal Gas-liquid Flow,” AIChE Journal, Vol. 22, pp. 47-55 https://doi.org/10.1002/aic.690220105
  4. Hewitt, G. F. and Roberts, D. N., 1969, “Studies of Two-phase Flow Patterns by Simultaneous Flash and X-Ray Photography,” AEREM2159
  5. Oshimowo, T. and Charles, M. E., 1974, “Vertical Two-phase Flow. Part1, Flow pattern Correlations,” Can, J. Chem. Eng., Vol. 52, pp. 25-35 https://doi.org/10.1002/cjce.5450520105
  6. Tomomi UMEDA, 1993, “Reduction of Noise Caused by Gas-liquid Two-phase Refrigerant Flow through an Expansion Valve,” JSME, Vol. 59, No. 557, pp. 243-248 https://doi.org/10.1299/kikaib.59.243
  7. Tatsumi KANNON, 1997, “Study on Noise Caused by Slug Flow through a Capillary Tube,” JSME, Vol. 63, No. 611, pp. 2392-2397 https://doi.org/10.1299/kikaib.63.611_2392
  8. Han, H. S., Shigeo, A., Mo, J. Y., Lee, J. K. and Song, Y. J., 2006, “Analyzing for Refrigerant Induced Noise for Split Type Air Conditioner Indoor Unit,” Transactions of the Korean Society for Noise and Vibration Engineering, Vol. 16, No. 3, pp. 240-246 https://doi.org/10.5050/KSNVN.2006.16.3.240
  9. Christopher, E. B., 1995, “Cavitation and Bubble Dynamics,” Oxford University Press
  10. Choi, S. W., Hwang, W. G., Seol, S. Y., Im, H. E. and Kim, S. S., 2004, “A Study on Reduction of Refrigerant Noise in Household Refrigerator,” Proceedings of the KSNVE Annual Autumn Conference 2004, pp. 1062-1066
  11. Hirakuni, S., 2004, “Noise Reduction Technology Caused by Refrigerant Two-phase Flow for Room Air Conditioner,” Japanese J. Multiphase Flow, Vol. 18, No. 1, pp. 23-30
  12. Park, J. H., Chang, E. Y. and Park, Y. S., 1996, “Definition and Improvement of the Sound which was Generated by Bubbles at the Accumulator of the Evaporator,” Transactions of the Korean Society for Noise and Vibration Engineering, Vol. 6, No. 4, pp. 513-519
  13. Lee, S. Y., Kim, B. J. and Kim, M. H., 1993, “Two-phase Flow Heat Transfer,” Daeyoung-Sa
  14. Minnaert, W. K., 1933, “On Musical Air Bubbles and the Sound of Running Water,” Phil. Mag.16, pp. 235-248 https://doi.org/10.1080/14786443309462277
  15. Strasberg, M., 1955, “Gas Bubbles as Sources of Sound in Liquids,” The Journal of the Acoustical Society of America, Vol. 28, No. 1, pp. 20-26 https://doi.org/10.1121/1.1908212

Cited by

  1. Prediction of Two-phase Flow Patterns and Noise Evaluation for Evaporator Pipe in a Refrigerator vol.21, pp.10, 2011, https://doi.org/10.5050/KSNVE.2011.21.10.916
  2. Active Control of Noise Transmitted through Ventilation Openings of the Machinery Room of Refrigerator vol.26, pp.4, 2016, https://doi.org/10.5050/KSNVE.2016.26.4.475