During the maintenance period at Korean nuclear power plants, internal exposure of radiation workers occurred by the inhalation of $^{131}I$ released to the reactor building when primary system opened. The internal radioactivity of radiation workers contaminated by $^{131}I$ was measured using a whole body counter. Intake estimation and the calculation of committed effective dose were also conducted conforming to the guidance of internal dose assessments from publications of International Commission on Radiological Protection. Because the uptake and excretion of $^{131}I$ in a body occur quickly and $^{131}I$ is accumulated in the thyroid gland, the estimated intakes showed differences depending on the counting time after intake. In addition, since ICRP publications do not provide the intake retention fraction (IRF) for whole body of $^{131}I$, the IRF for thyroid was substitutionally used to calculate the intake and subsequently this caused more error in intake estimation. Thus, intake estimation and the calculation of committed effective dose were conducted by manual calculation. In this study, the IRF for whole body was also calculated newly and was verified. During this process, the estimated intake and committed effective dose were reviewed and compared using several computer codes for internal dosimetry.
국내 원전의 계획예방정비기간 중에 원자로계통의 개방과정에서 원자로건물내 공기 중으로 누설된 $^{131}I$의 체내 흡입으로 원전종사자의 내부피폭이 발생하였다. 이에 따라 원전에서 보유하고 있는 전신계측기(Whole body counter)를 이용하여 내부방사능을 측정하였다. 이들 측정값을 근거로 국제방사선방호위원회(ICRP)의 내부피폭 선량평가 지침을 적용하여 섭취량을 산정하고, 내부 피폭 방사선량을 평가하였다. $^{131}I$은 체내에서 섭취와 배설이 빠르고 갑상선으로 재축적이 일어나기 때문에 섭취 후 측정시점에 따라 섭취량이 차이를 보였다. 또한 ICRP 간행물에서 $^{131}I$의 전선에 대한 섭취잔류분율 자료를 제공하고 있지 않아 갑상선 섭취잔류분율 자료를 이용함으로써 섭취량 평가에서 오차를 나타내었다. 이에 따라 수계산과정으로 섭취량을 산정하고 예탁유효선량을 평가하였다. 한편 전선에 대한 섭취잔류분율을 새로 계산하였으며, 이 결과를 검증하였다. 또한 국제적으로 이용되고 있는 내부 피폭 선량평가 전신코드들 이용하여 섭취량 산정과 내부피폭 선량평가 평가결과에 대한 비교 계산이 병행하여 이루어졌다.