DOI QR코드

DOI QR Code

모세관 길이와 관경 변화에 따른 R-1270의 성능특성

System Performance for Length and Diameter of Capillary Tube using R-1270

  • 이호생 (부경대학교) ;
  • 김현우 (부경대학교 대학원 냉동공조공학과) ;
  • 최원재 (부경대학교 대학원 냉동공조공학과) ;
  • 윤정인 (부경대학교 기계공학부)
  • 발행 : 2009.07.31

초록

Experimental results for performance characteristics of HCs refrigerant R-1270 and HCFC refrigerant R-22 during refrigeration system using capillary tube are presented. The system consists of compressor, condenser, capillary tube, evaporator and peripheral devices. Length and diameter of capillary tube are varied for this investigation. The refrigerant mass flow increased as the diameter of capillary tube increased and the length of capillary tube decreased. A refrigeration capacity and compressor work of R-1270 in same length and diameter of capillary tube showed the higher values than those of R-22. A coefficient of performance showed the highest value when the length and diameter of capillary tube are 105 cm and 1.8 mm in this experimental conditions.

키워드

참고문헌

  1. Montreal Protocol on Substances That Deplete the Ozone Layer, 1989, Final Act, United Nations Environment Programme
  2. Global Environmental Change Report, A brief analysis of the Kyoto protocol, Vol. IX, No. 24, December, 1997
  3. James. R. W. and Missenden. J. F., "The use of propane in domestic refrigerators. International Journal of Refrigeration", Vol. 15. No. 2, pp. 95-100, 1992 https://doi.org/10.1016/0140-7007(92)90033-Q
  4. Hong, K. S., Hwang, I. N. and Min, M. K., "The Effect of Oil on Refrigerant Flow through Capillary Tubes," Trans. of the Sarek. Vol. 12, No. 9, pp 791-801, 2000
  5. 최종민 등 2인, '대체냉매를 적용한 일반화된 모세관의 유량예측 상관식', 설비공학논문집, Vol. 15, No. 9. pp. 744-750, 2003
  6. Lee. H. S., Yoon, J. I., Kim, J. D., and Predeep Bansal, "Evaporating heat transfer and pressure drop of hydrocarbon refrigerant in 9.52 and 12.70 mm smooth tube", International Journal of Mass and Heat Transfer, Vol. 48, No. 12, pp. 2351-2359, 2005 https://doi.org/10.1016/j.ijheatmasstransfer.2005.01.012
  7. Yoon, J. I., Lee. H. S., Lee, K. B., Kim, J. D., and Predeep Bansal, "Condensing heat transfer characteristics of hydrocarbon refrigerants in 9.52 and 12.70 mm smooth tube", Heat Mass Transfer, Vol. 42, No. 6, pp. 144-149, 2005 https://doi.org/10.1007/s00231-005-0004-7