Clinical Observation on Blood Flow of Facial Acupuncture Points in Bell's Palsy Patients by Doppler Ultrasound

도플러 초음파검사를 이용한 안면마비 환자의 안면부 경혈의 혈류 관찰

  • Yin, Chang-Shik (Acupuncture and Meridian Science Research Center, Kyung Hee University) ;
  • Bae, Young-Min (SOI-KOREA Center, Korea Electrotechnology Research Institute) ;
  • Choi, Yang-Sik (Dept. of Acupuncture & Moxibustion, College of Oriental Medicine, Kyung Hee University) ;
  • Ko, Jeong-Min (Dept. of Acupuncture & Moxibustion, College of Oriental Medicine, Kyung Hee University) ;
  • Kim, Sergey (SOI-KOREA Center, Korea Electrotechnology Research Institute) ;
  • Kang, Uk (SOI-KOREA Center, Korea Electrotechnology Research Institute) ;
  • Lee, Sang-Hoon (Dept. of Acupuncture & Moxibustion, College of Oriental Medicine, Kyung Hee University)
  • 인창식 (경희대학교 침구경락과학연구센터) ;
  • 배영민 (한국전기연구원 SOI-KOREA센터) ;
  • 최양식 (경희대학교 한의과대학 침구학교실) ;
  • 고정민 (경희대학교 한의과대학 침구학교실) ;
  • 김세르게이 (한국전기연구원 SOI-KOREA센터) ;
  • 강욱 (한국전기연구원 SOI-KOREA센터) ;
  • 이상훈 (경희대학교 한의과대학 침구학교실)
  • Published : 2009.04.20

Abstract

Objectives : The aim of this study was to investigate whether Doppler ultrasound device is applicable for the evaluation of facial palsy patients. Methods : A total of 25 patients participated in the first assessment and 22 of them finished a follow-up assessment one week later. An assessment comprised of a Minimax-Doppler-K device examination on bilateral acupoints $ST_5$, $SI_{19}$, $ST_2$, and $BL_1$, House-Brackmann grading, and subjective symptom questionnaire. Measurement reliability was assessed and clinically meaningful variations of Doppler measurement values were explored. Results : Doppler ultrasound examination revealed a significant difference of some measurement values between values of the symptom side and the contralateral side, between groups of severe paralysis and moderate paralysis, and between groups of short duration(0-3 weeks) and long duration (3 weeks-5 months) by non-parametric analyses (p<0.05). Several re-examination values showed a significant correlation with the first examination values by Spearman's correlation tests (p<0.05). Conclusions : This study revealed several possibilities for the clinical application of this device. Further validity tests and device improvements for a user's convenience would be helpful for its practical application.

Keywords

References

  1. 김창환, 김용석. 마비질환클리닉. 서울 : 정담. 1996: 233.
  2. 홍원식. 精校黃帝內經靈樞. 서울 : 동양의학연구원. 1985 : 102.
  3. Nowak DA, Linder S, Topka H. Diagnostic relevance of transcranial magnetic and electric stimulation of the facial nerve in the management of facial palsy. Clin Neurophysiol. 2005 ; 116(9) : 2051-57. https://doi.org/10.1016/j.clinph.2005.05.007
  4. Coulson SE, Croxson GR, Adams RD, O'Dwyer NJ. Reliability of the "Sydney," "Sunnybrook," and "House Brackmann" facial grading systems to assess voluntary movement and synkinesis after facial nerve paralysis. Otolaryngol Head Neck Surg. 2005 ; 132(4) : 543-9. https://doi.org/10.1016/j.otohns.2005.01.027
  5. Kress B, Griesbeck F, Stippich C, Bahren W, Sartor K. Bell palsy : quantitative analysis of MR imaging data as a method of predicting outcome. Radiology. 2004 ; 230(2) : 504-9. https://doi.org/10.1148/radiol.2302021353
  6. Chow LC, Tam RC, Li MF. Use of electro-neurography as a prognostic indicator of Bell's palsy in Chinese patients. Otol Neurotol. 2002 ; 23(4) : 598-601. https://doi.org/10.1097/00129492-200207000-00033
  7. Kazlov VA, Artiushenko NK, Shalak OV, Vasiliev AV, Girina ME, Girin II, Morozova EA, Monastyrenko AA. Doppler ultrasound examination of macro- and microcirculatory vessels of neck, face, and mouth in healthy and some pathological conditions. Saint Petersburg : SP Minimax Ltd. 2000 : 10-3.
  8. Kasse CA, Ferri RG, Vietler EYC, Leonhardt FD, Testa JRG, Cruz OLM. Clinical data and prognosis in 1521 cases of Bell"s palsy Int Congr Ser. 2003 ; 1240 : 641-7. https://doi.org/10.1016/S0531-5131(03)00757-X
  9. Li Y, Liang FR, Yu SG, Li CD, Hu LX, Zhou D, Yuan XL, Li Y, Xia XH. Efficacy of acupuncture and moxibustion in treating Bell's palsy : a multicenter randomized controlled trial in China. Chin Med J (Engl). 2004 ; 117(10) : 1502-6.
  10. Kang SK, Kim YS. Clinical observation of Bell's [palsy. KOMS. 1995 ; 16(2) : 9-16.
  11. Ariji Y, Sakuma S, Kimura Y, Kawamata A, Toyama M, Kurita K, Ito Y, Ariji E. Colour Doppler sonographic analysis of blood-flow velocity in the human facial artery and changes in masseter muscle thickness during low-level static contraction. Arch Oral Biol. 2001b ; 46(11) : 1059-64. https://doi.org/10.1016/S0003-9969(01)00062-0
  12. Izumi H. Nervous control of blood flow in the orofacial region. Pharmacol Ther. 1999 ; 81 (2) : 141-61. https://doi.org/10.1016/S0163-7258(98)00040-0
  13. Ghali S, Knox KR, Verbesey J. Scarpidis U, Izadi K, Ganchi PA. Effects of lidocaine and epinephrine on cutaneous blood flow. J Plast Reconstr Aesthet Surg. 2007 [Epub ahead of print]
  14. Wohlrab J. Lueftl M, Marsch WC. Persistent erythema and edema of the midthird and upper aspect of the face (morbus morbihan) : evidence of hidden immunologic contact urticaria and impaired lymphatic drainage. J Am Acad Dermatol. 2005 ; 52(4) : 595-602. https://doi.org/10.1016/j.jaad.2004.08.061
  15. Ariji Y, Kimura Y, Gotoh M, Sakuma S, Zhao YP, Ariji E. Blood flow in and around the masseter muscle: normal and pathologic features demonstrated by color Doppler sonography. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2001a ; 91(4) : 472-82. https://doi.org/10.1067/moe.2001.111760
  16. Zhao YP, Ariji Y, Gotoh M, Kurita K, Natsume N, Ma XC, Ariji E. Color Doppler sonography of the facial artery in the anterior face. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2002 ; 93(2) : 195-201. https://doi.org/10.1067/moe.2002.120054
  17. Gerrits HL, de Haan A, Sargeant AJ, van Langen H, Hopman MT. Peripheral vascular changes after electrically stimulated cycle training in people with spinal cord injury. Arch Phys Med Rehabil. 2001 ; 82(6) : 832-9. https://doi.org/10.1053/apmr.2001.23305