References
- Yoon, Y., Kim, Y. and Min, M., "A Study on Leakage Characteristics of a Scroll Compressor with alternative Refrigerants of R22," Korean J. of Airconditioning and Refrigeration Engineering, Vol. 13,No. 5, pp. 377-387, 2001
- Mitarai, N., Itou, T., Toda, N. and Suetake, H.,"Development of scroll compressor for alternative refrigerant in room air conditioner," Proc. International Symposium on HCFC Alternative Refrigerants, pp. 55-60, 1998
- Kang, S.-H., "Conceptual system design of multistage centrifugal air-compressor," Trans. of KSME(B), Vol. 21, No. 8, pp. 1086-1093, 1997
- Jeong, J. and Lee, H., "Series design of compressor for two-stage centrifugal chiller," KSME Int. J., Vol.17, No. 2, pp. 288-295, 2003 https://doi.org/10.1007/BF02984400
- Kwon, Y. C., Jin, E. S., Heo, S. H., Kim, D. H., Hong, J. T. and Moon, J. M., "Performance of Compressor with Variable Capacity," Energy Engg. J., Vol. 13, No.3, pp.214-218, 2004
- Park, H. H., Park, Y. C. and Kim, Y. C., "Performance Analysis on the Variable Speed Scroll Compressor with Operating Conditions," Korean J. of Air-conditioning and Refrigeration Engineering, Vol. 12,No. 7, pp. 649-658, 2000
- Lee, H. W., Ko, K. W., Kwon, Y. C., Lee, J. H. andLee, Y. J, "Development of Performance Evaluationand Control System of Multi-Air Conditioner," Proc. of KSPE Spring Conference, pp. 1107-1114, 2005
- Tassou, S. A., Marquand, C. J. and Wilson, D. R.,"Comparison of the performance of capacity controlled and conventional on/off controlled heat pumps," Appl. Energy, Vol. 14, No. 4, pp. 241-256, 1983 https://doi.org/10.1016/0306-2619(83)90051-X
- Beetom, W. L. and Pham, H. M., "Vapor-injected scroll compressors," ASHRAE J., Vol. 45, No. 4, pp.22-27, 2003
- Oh, S. K., Chang, P., Choi, J. K. and Lee, I., "Design of a variable capacity rotary compressor using bypass method," International Compressor Engineering Conference, pp. 12-15, 2004
- Xiaosong, Z., Guoying, X., Chan, K. T. and Yi, X.,"A novel energy-saving method for air-cooled chiller plant by parallel connection," Appl. Thermal Engineering, Vol. 26, No. 16, pp. 2012-2019, 2006 https://doi.org/10.1016/j.applthermaleng.2006.01.005
- Powers, J. C., "TS compressors advance heat pump system operation beyond 'stop' and 'go'," The Air Conditioning, Heating and Refrigeration News, 1999
- Shimura, Y., Tateuchi, T. and Sugiura, H., "Inverter control systems in a residential heat-pump air conditioner," American Society of Heating, Refrigerating and Air-conditioning Engineers. Annual Meeting, Vol. 91, No. 2B, pp. 1541-1554, 1985
- Ischii, N., Yamamura, M., Muramatsy, S., Yamamoto,S. and Sakai, M., "Mechanical efficiency of avariable speed scroll compressor," International Compressor Engineering Conference, pp. 192-199,1990
- Park, Y. C., Kim, Y. C. and Min, M.-K.,"Performance analysis on a multi-type inverter air conditioner," International Compressor Engineering Conference, pp. 12-15, 2001
- Sisk, F. J., "Dual capacity compressor with reversible motor and controls arrangement therefore," US Patent, No. 4236874, 1980
- Bae, Y. J., Kim, J.-B., Kim, J. K. and Chang, Y. J.,"Mode Change Design for Capacity Modulation in Reciprocating Compressor," J. Mech. Sci. and Tech., Vol. 22, No. 7, pp. 1391-1399, 2008 https://doi.org/10.1007/s12206-008-0412-y
- Park, S.-S., Kim, Y. J., and Yoo, S. M., "Analysis of Herringbone Grooved Journal Bearing Using Generalized Coordinate Transformation," J. of the Korean Society of Tribologists and Lubrication Engineers, Vol. 16, No. 6, pp. 432-439, 2000