DOI QR코드

DOI QR Code

Evaluation of slip coefficient of slip critical joints with high strength bolts

  • Nah, Hwan-Seon (Environmental & Structural Lab., Korea Electric Power Research Institute) ;
  • Lee, Hyeon-Ju (Environmental & Structural Lab., Korea Electric Power Research Institute) ;
  • Kim, Kang-Seok (Environmental & Structural Lab., Korea Electric Power Research Institute) ;
  • Kim, Woo-Bum (Architectural Engineering Department, Kongju National University)
  • Received : 2008.08.11
  • Accepted : 2009.06.02
  • Published : 2009.07.10

Abstract

A slip critical joint has various values to adopt the proper slip coefficient in various conditions of faying surfaces in the following codes: AISC, AIJ and Eurocode 3. However, the Korean Building Code still regulates the unique slip coefficient, 0.45, regardless of the diverse faying conditions. In this study, the slip resistance test, including five kinds of surface treatments were conducted to obtain the proper slip coefficients available to steel plate KS SM490A. The faying surfaces were comprised of a clean mill, rust, red lead paint, zinc primer, and shot blast treatment. The candidates for high strength bolts were torque-shear bolts, torque-shear bolts with zinc coating, and ASTM A490 bolts. Based on the test results, the specimens with a shot blasted surface and rusted surface exhibited $k_s$, 0.61, and 0.5, respectively. It is recommended that the specimens with zinc primer exhibit $k_s{\geq}0.40$. The clean mill treated surface had prominently lower values, 0.27. For red lead painted treatment, the thickness of the coating affects the determinant of slip coefficient, so it is necessary to establish a minimum $k_s$ of 0.2, with a coating thickness of 65 ${\mu}m$. During 1,000 hours of relaxation, the uncoated surfaces exhibited the loss of clamping force behind 3%, while the coated surfaces within a certain limited thickness exhibited the loss of clamping within a range of 4.71% and 8.37%.

Keywords

References

  1. Architectural Institute of Japan (1993), Recommendations for the Design Fabrication of High Strength Bolted Joints, AIJ
  2. Architectural Institute of Japan (2003), Guidebook on Design and Fabrication of High Strength Bolted Connections, AIJ
  3. ASTM F2280 (2006), "Twist off" type Tension Control Structural Bolt/Nut/Washer Assemblies, Steel, Heat Treated, 150 ksi Minimum Tensile Strength, ASTM committee
  4. Carl J. Lehmen (2002), Direct Tension Indicators, Practical Periodical on Structural Design and Construction, May, 48-51
  5. Charles J. Oswald, Robert J. Dexter, and Steven K. Brauer (1996), "Field study of pretension in large diameter A490 bolts", J. Bridge Eng., Aug. 121-126 https://doi.org/10.1061/(ASCE)1084-0702(1996)1:3(121)
  6. Drean, M., Habraken, A., Boucher, A. and Muzeau, J.P. (2002), "Swaged bolts: Modeling of the installation process and numerical analysis of the mechanical behavior", J. Comput. Struct., 80, 2361-2373 https://doi.org/10.1016/S0045-7949(02)00240-7
  7. Fukuoka, T. and Takaki, T. (2004), Evaluations of the Tightening Process of Bolted Joint with Elastic Angle Control Method, Analysis of Bolted Joints, July, PVP. 478, 11-18 https://doi.org/10.1115/PVP2004-2617
  8. Geoffrey L. Kulak and Scott T. Undershutte (1998), "Tension control bolts: strength and installation", J. Bridge Eng., Feb., 15-20 https://doi.org/10.1061/(ASCE)1084-0702(1998)3:1(15)
  9. Geoffrey L. Kulak, John W. Fisher, John H.A. Struik (2001), Guide to Design Criteria for Bolted and Riveted Joints, $2^{nd}$ Edition, AISC, Inc
  10. John H. Bickford (1990), An Introduction to the Design and Behavior of Bolted Joints, Marcel Dekker Inc., Madison Avenue, New York, NJ
  11. John H. Bickford and Sayed Nassar (1998), "Handbook of bolts and bolted joints", Marcel Dekker Inc., Madison Avenue, New York, NJ
  12. Jun Yang and John DeWolf (1999), "Mathematical model for relaxation in high strength bolted connections", J. Struct. Eng., Aug., 803-808 https://doi.org/10.1061/(ASCE)0733-9445(1999)125:8(803)
  13. Jun Yang and John DeWolf (2000), "Relaxation in high strength bolted connections using galvanized steel", J. Bridge Eng., May, 99-106 https://doi.org/10.1061/(ASCE)1084-0702(2000)5:2(99)
  14. Kim, J.H. (2001), "An experimental study on the structural behavior in friction type bolted joints clamping by F13T grade high strength bolt", J. Architect. Inst. Korea, 17(12)
  15. Kim, J.H. and Choi, S.M. (2001), "An experimental study on the structural behavior in friction type bolted joint under cyclic loading", J. Architect. Inst. Korea, 17(1)
  16. Kim, J.H., Woo, H.S. and Choi, S.M. (2003), "Design code and resistance capacity for slip critical connections of high strength bolts", J. Architect. Inst. Korea, 19(4), 27-35
  17. Nah, H.S., Kim, K.S., Lee, H.J. and Kim, W.B. (2008), "Evaluation on clamping force of high strength bolts by temperature parameter", J. Architect. Inst. Korea, 20(3), 399-407
  18. Park, Y.M. and Song, T.R. (2000), "Experimental evaluation of slip coefficients of friction type bolted connections with weathering steel", J. Korean Steel Struct., 12(2), 167-175
  19. RCSC Committee A.1, American Institute of Steel Construction, Inc. (2000), "Specification for structural joints using ASTM A325 or A490 bolts", Jun. AISC, Inc
  20. Turvey, G.J. and Wang, P. (2005), "Failure of Pultruded GRP Single Bolt Tension Joints under Hot-wet Conditions", J. Compos. Struct., Aug., 1-7

Cited by

  1. Estimation on Clamping Force of High Strength Bolts Considering Temperature Variable of Both Site conditions and Indoor Environments vol.6, pp.3, 2015, https://doi.org/10.11004/kosacs.2015.6.3.032
  2. Estimation of Long Term Clamping Force of High Strength Bolts By Coating Thickness Parameters of Slip Faying Surfaces vol.3, pp.1, 2012, https://doi.org/10.11004/kosacs.2012.3.1.008
  3. Evaluating relaxation of high-strength bolts by parameters on slip faying surfaces of bolted connections vol.10, pp.3, 2010, https://doi.org/10.1007/BF03215838
  4. 01.30: Evaluation on clamping load of high strength bolts under ambient environment vol.1, pp.2-3, 2017, https://doi.org/10.1002/cepa.78
  5. A Study on the Secure Plan of Clamping Force according to the Variation of Torque-Coefficient in Torque-Shear High Strength Bolts vol.5, pp.3, 2014, https://doi.org/10.11004/kosacs.2014.5.3.008
  6. Evaluating long-term relaxation of high strength bolts considering coating on slip faying surface vol.16, pp.6, 2014, https://doi.org/10.12989/scs.2014.16.6.703
  7. Three-dimensional numerical and linearly distributed multi-parameter fitted analytical modeling of hybrid beam–column with partially welded flush end-plate connection vol.21, pp.12, 2018, https://doi.org/10.1177/1369433218754698
  8. Evaluate the Clamping Force of Torque-Shear High Strength Bolts vol.18, pp.3, 2018, https://doi.org/10.1007/s13296-018-0066-2
  9. Estimation on clamping load of high strength bolts considering various environment conditions vol.24, pp.4, 2009, https://doi.org/10.12989/scs.2017.24.4.399