DOI QR코드

DOI QR Code

Structural evaluation of an existing steel natatorium by FEM and dynamic measurement

  • Liu, Wei (Department of Astronautics Science and Mechanics, Harbin Institute of Technology) ;
  • Gao, Wei-Cheng (Department of Astronautics Science and Mechanics, Harbin Institute of Technology) ;
  • Sun, Yi (Department of Astronautics Science and Mechanics, Harbin Institute of Technology) ;
  • Yu, Yan-Lei (Department of Astronautics Science and Mechanics, Harbin Institute of Technology)
  • Received : 2008.06.05
  • Accepted : 2009.02.27
  • Published : 2009.03.30

Abstract

Based on numerical and experimental methods, a systematic structural evaluation of a steel natatorium in service was carried out in detail in this paper. Planning of inspection tasks was proposed firstly according to some national codes in China in order to obtain the economic and reliable results. The field visual inspections and static computation were conducted in turn under in-service environmental conditions. Further a three-dimensional finite element model was developed according to its factual geometry properties obtained from the field inspection. An analytical modal analysis was performed to provide the analytical modal properties. The field vibration tests on the natatorium were conducted and then two different system identification methods were used to obtain the dynamic characteristics of the natatorium. A good correlation was achieved in results obtained from the two system identification methods and the finite element method (FEM). The numerical and experimental results demonstrated that the main structure of the natatorium in its present status is safe and it still satisfies the demand of the national codes in China. But the roof system such as purlines and skeletons must be removed and rebuilt completely. Moreover the system identification results showed that field vibration test is sufficient to identify the reliable dynamic properties of the natatorium. The constructive suggestion on structural evaluation of the natatorium is that periodic assessment work must be maintained to ensure the natatorium's safety in the future.

Keywords

References

  1. Abdel-Ghaffar, A.M. and Scanlan, R.H. (1985), 'Ambient vibration studies of Golden Gate bridge, I: Suspended structure', J. Eng. Mech., 111(4), 463-482 https://doi.org/10.1061/(ASCE)0733-9399(1985)111:4(463)
  2. $ANSYS{\circledR}$. (1999), User's Manual, Revision 5.6. USA: Swanson Analysis System
  3. Brincker, R., Zhang, L.M. and Anderson, P. (2001), 'Modal identification of output-only systems using frequency domain decomposition', Smart Mater. Struct., 10(3), 441-445 https://doi.org/10.1088/0964-1726/10/3/303
  4. Cunha, A., Caetano, E. and Delgado, R. (2001), 'Dynamic tests on large cable-stayed bridge', J. Bridge Eng., 6(1), 54-62 https://doi.org/10.1061/(ASCE)1084-0702(2001)6:1(54)
  5. Galvin, P. and Dominguez, J. (2007), 'Dynamic analysis of a cable-stayed deck steel arch bridge', J. Constr. Steel Res., 63(8), 1024-1035 https://doi.org/10.1016/j.jcsr.2006.11.001
  6. Gentile, C. and Saisi, A. (2007), 'Ambient vibration testing of historic masonry towers for structural identification and damage assessment', Constr. Build. Mater., 21(6), 1311-1321 https://doi.org/10.1016/j.conbuildmat.2006.01.007
  7. Hai, D.T. (2006), 'Current status of existing railway bridges in Vietnam: an overview of steel deficiencies', J. Constr. Steel Res., 62(10), 987-994 https://doi.org/10.1016/j.jcsr.2006.01.009
  8. Jaishi, B., Ren, W.X., Zong, Z.H. and Maskey, P.N. (2003), 'Dynamic and seismic performance of old multitiered temples in Nepal', Eng. Struct., 25(14), 1827-1839 https://doi.org/10.1016/j.engstruct.2003.08.006
  9. Luo, Y.Z. (2003), MSTCAD Instruction Manual. Space Structures Research Center of Zhejiang University. (in Chinese)
  10. Magalhaes, F., Caetano, E. and Cunha, A. (2008), 'Operational modal analysis and finite element model correlation of the Braga Stadium suspended roof', Eng. Struct., 30(6), 1688-1698 https://doi.org/10.1016/j.engstruct.2007.11.010
  11. McCrea, A., Chamberlain, D. and Navon, R. (2002), 'Automated inspection and restoration of steel bridges - a critical review of methods and enabling technologies', Automat. Constr., 11(4), 351-373 https://doi.org/10.1016/S0926-5805(01)00079-6
  12. Melchers, R.E. (2005), 'The effect of corrosion on the structural reliability of steel offshore structures', Corrosion Science, 47(10), 2391-2410 https://doi.org/10.1016/j.corsci.2005.04.004
  13. Onoufriou, T. and Frangopol, D.M. (2002), 'Reliability-based inspection optimization of complex structures: A brief retrospective', Comput. Struct., 80(12), 1133-1144 https://doi.org/10.1016/S0045-7949(02)00071-8
  14. Ren, W.X., Peng, X.L. and Lin, Y.Q. (2005), 'Experimental and analytical studies on dynamic characteristics of a large span cable-stayed bridge', Eng. Struct., 27(1), 535-548
  15. Siringoringo, D.M. and Fujino, Y. (2008), 'System identification of suspension bridge from ambient vibration response', Eng. Struct., 30(1), 462-477
  16. Van Overschee, P. and De Moor, B. (1996), Subspace Identification for Linear Systems - Theory Implementation Applications, Kluwer Academic Publishers, Dordrecht (Netherlands)
  17. Wang, T., Zhang, L.M. and Tamura, Y. (2005), 'An operational modal analysis methods in frequency and spatial domain', Earthq. Eng. Eng. Vib., 4(2), 295-300 https://doi.org/10.1007/s11803-005-0012-0
  18. Wenzel, H. and Pichler, D. (2001). Ambient Vibration Monitoring. John Wiley & Sons, Ltd. New York
  19. Zhang, L.M., Brincker, R. and Andersen, P. (2005), 'An overview of operational modal analysis: Major development and issues', Proceedings of the 1st International Operational Modal Analysis Conference, Copenhagen, Denmark, 179-190
  20. Zhang, L.M., Wang, T. and Tamura, Y. (2005), 'A Frequency-spatial domain decomposition (FSDD) technique for operational modal analysis', Proceeding of the 1st International Operational Modal Analysis Conference, Copenhagen, Denmark, 551-561