The Efficacy of Fluorograb for Paediatric Patients Dose Reduction during Pneumatic Reduction and Voiding Cystourethrography(VCUG)

영.유아의 배뇨성 방광-요도 조영술 및 방사선 공기 주입 정복술시 피폭선량 경감을 위한 fluorograb의 유용성

  • 김상태 (분당서울대학교병원 영상의학과) ;
  • 최지원 (전주대학교 방사선학과)
  • Received : 2009.09.15
  • Accepted : 2009.11.05
  • Published : 2009.12.28

Abstract

The Pneumatic Reduction and VCUG (Voiding Cystourethrography) are commonly used in the paediatric age group. The procedures had a particularly long fluroscopic screening time, despite a successful outcome for paediatric patients. Pneumatic Reduction and VCUG almost invariably requires fluoroscopic guidance which does confer a radiation dose. This article contains suggestions on how the radiation dose to paediatric patients from Pneumatic Reduction and VCUG can be made "as low as reasonably achievable" (ALARA). The aim of our study was eliminated in spot image applying the FluoroGrab, which has function of capturing an image of interest area from the picturing while fluoroscopic procedures. FluoroGrab has clinical value equivalent to the spot image, and is applied to the most recent fluoroscopic procedures. The radiologist and the radiographers should consider new option for decreasing the radiation exposure delivered to paediatric patients by making equipment modifications to the fluoroscopy to optimize radiation exposure reduction techniques. Thus, we propose the FluoroGrab instead of spot exposure for the reduction of patient exposure dose in paediatric, and try to confirm the effect of the mitigating amount of radiation exposure to paediatric patients when pneumatic reduction and VCUG. Fluorograb is the safe and useful method that shows the equivalent level of accuracy to spot exposure, and to minimize the radiation load to paediatric patients are to be the substitute for the spot exposure for Pneumatic Reduction and VCUG.

공기주입 정복술(pneumatic reduction) 및 방사선 배뇨성 방광요도 조영술(Voiding Cystourethrography: 이하 VCUG)는 일반적으로 영,유아에게서 행해지는데 이들 검사는 투시촬영과 spot 촬영으로 이루어지며 이때 투시촬영으로 인한 방사선 피폭은 불가피한 것이나 spot 촬영으로 인한 피폭은 투시 화면상의 관심영상을 capture하는 기능인 fluorograb을 이용하여 제거할 수 있다. fluorograb은 spot영상과 비슷한 진단가치를 지니고 있으며 최근 사용되고 있는 대부분의 투시촬영장비에서 지원되는 기능이지만 다수의 의사 및 방사선사는 이 기능을 인지하지 못하고 있거나 인지하고는 있으나 습관적으로 spot 촬영을 행하고 있는 실정이다. 이는 방사선에 매우 민감한 연령대에 속한 영.유아에서 적게는 10장 미만에서 많게는 20장 이상을 spot 촬영하게 되는 공기주입 정복술 및 VCUG에서 그 영향이 적지 않다 하겠다. 따라서 공기주입 정복술 및 VCUG 시행시 spot 촬영으로 인한 영.유아의 피폭을 줄이기 위한 방법으로 spot 촬영을 대신한 fluorograb을 제안하며 이로 인한 기존의 공기주입 정복술 및 VCUG 시행 시 영 유아의 피폭선량 경감 효과를 증명하고자 하였다. 공기주입 정복술 및 VCUG 의 진단에 fluorograb은 spot 촬영과 비슷한 수준의 정확도를 보이는 안전하고 유용한 방법이여 공기주입 정복술 및 VCUG 시행 시 spot 촬영을 대체할 수 있을 것으로 생각한다.

Keywords

References

  1. 윤춘식, 영.유아 및 소아의 응급 위장관 질환의 초음파검사. 대한초음파의학회지, 20, pp.239-255, 2001.
  2. 황대현, 소아의 요로 감염군에서의 초음파검사의 의의. 대한방사선의학회지 26, pp.1265-1271, 1990.
  3. F. D. Pazik, R. J. Staton, J. L. Williams, M. M. Arreola, D. E. Hintenlang and W. E. Bolch. Organ and effective doses in newborns and infants undergoing voiding cystourethrograms (VCUG): A comparison of stylized and tomographic phantoms. Med. Phys. 34, pp.294-306, 2007. https://doi.org/10.1118/1.2402329
  4. P. Andreo. Monte Carlo techniques in medical radiation physics. Phys. Med. Biol. 36, pp.861-920, 1991. https://doi.org/10.1088/0031-9155/36/7/001
  5. M. Tapiovaara, M. Lakkisto, and A. Servomaa, PCXMC: A PC-based Monte Carlo program for calculating patient doses in medical x-ray examinations. Report STUK-A139. Helsinki: Finnish Centre for Radiation and Nuclear Safety, 1997.
  6. M. Cristy, Mathematical phantoms representing children of various ages for use in estimates of internal dose, NUREG/CR-1159, ORNL/NUREG/TM-367. Oak Ridge: Oak Ridge National Laboratory, 1980.
  7. D. G. Jones and B. F. Wall, "Organ Dose from Medical X-ray Examinations Calculated Using Monte Carlo Techniques," Report NRPB-R186, National Radiological Protection Board, Chilton, Didcot, UK, 1985.
  8. D. Hart, D. G. Jones and B. F. Wall, "Normalised organ doses for paediatric x-ray examinations calculated using Monte Carlo techniques," NRPB-SR279. Chilton: NRPB; 1996.
  9. D. P. Griffith, M. J. Gleeson, G. Politis, and S. Glaze, Effectiveness of radiation control program for Dornier HM3 lithotriptor. Urology 33, pp.20-5, 1989. https://doi.org/10.1016/0090-4295(89)90060-5
  10. D. Hart, B. F. Wall, P. C. Shrimpton, D. R. Bungay, and D. R. Dance, "Reference doses and patient size in paediatric radiology," Chilton: NRPB-R318, 2000.
  11. A. Herrmann, H. Bonel, A. Stablier, Chest imaging with flat-panel detecter at low and standard doses: comparison with storage phosphor technology in normal patients. Eur. Radiol. 12, pp.385-390, 2002. https://doi.org/10.1007/s00330-001-1166-4
  12. J. S. Benson. "Patient and physician radiation exposure during fluoroscopy. In Rock Ville Center for devices and radiological health (HFZ-1)," food and drug administration 20857.
  13. S. S. Chu, W. Y. Kim. Management and counermearsure for fluoroscopy. Korean J of Radiotechnol. Vol.14, No.1, pp.17-24, 1981.
  14. United Nations Scientific Committee on the Effects of Atomic Radiation, Sources and Effects if Ionizing Radiation, UNSCEAR 2000 Report to the General Assembly with Scientific Annexes, Volume I: Sources, United Nations New York. 2000.