참고문헌
- Soong, T. T. and Dargush, G. F., 1997, “Passive Energy Dissipation Systems in Structural Engineering,” John Wiley & Sons
- Heo, J. S., Park, E. C., Lee, S. H., Lee, S. K., Kim, H. J., Cho, B. H., Jo, J. S., Kim, D. Y. and Min, K. W., 2008, “A Tuned Liquid Mass Damper(TLMD) for Controlling Bi-directional Responses of a Building Structure,” Transactions of the Korean Society for Noise and Vibration Engineering, Vol. 18, No. 3, pp. 345-355 https://doi.org/10.5050/KSNVN.2008.18.3.345
- Sakai, F., Takaeda, S. and Tamaki, T., 1989, “Tunes Liquid Column Damper-new Type Device for Suppression of Building Vibration,” Proc. International Conference on High-rise Building, pp. 926-931
- Hitchcock, P. A., Kwok, K. C. S., Watkins, R. and Samali, D. B., 1997, "Characteristic of Liquid Column Vibrations Absorbers(TLCD)- I" Engineering Structures, Vol. 19, pp. 126-134 https://doi.org/10.1016/S0141-0296(96)00042-9
- Hitchcock, P. A., Kwok, K. C. S., Watkins, R. and Samali, D. B., 1997, “Characteristic of Liquid Column Vibrations Absorbers(TLCD)-II,” Engineering Structures, Vol. 19, pp. 135-144 https://doi.org/10.1016/S0141-0296(96)00044-2
- Gao, H., Kwok, K. C. S. and Samali, B., 1997, “Optimization of Tuned Liquid Column Dampers,” Engineering Structures, Vol. 19, pp. 476-486 https://doi.org/10.1016/S0141-0296(96)00099-5
- Chang, C. C. and Hsu, C. T., 1998, “Control Performance of Liquid Column Vibration Absorbers,” Engineering Structures, Vol. 20, pp. 580-586 https://doi.org/10.1016/S0141-0296(97)00062-X
- Balendra, T., Wang, C. M. and Rakesh G., 1998, “Effectiveness of TLCD on Various Structural Systems,” Engineering Structures, Vol. 21, pp. 291-305
- Yalla, S. K., 2001, “Liquid Dampers for Mitigation of Structural Response,” Theoretical Development and Experimental Validation, Ph.D. Thesis, University of Notre Dame
- Wu, J. C., Shin, M. H., Lin, Y. Y. and Shen, Y. C., 2005, “Design Guidelines for Tuned Liquid Column Damper for Structures Responding to Wind,” Engineering Structures, Vol. 27, pp. 1893-1905 https://doi.org/10.1016/j.engstruct.2005.05.009
- Heo, J. S., Park, E., Lee, S. K., Lee, S. H., Kim, H. J., Jo, J. S., Cho, B. H., Joo, S.-J. and Min, K. W., 2008, “Performance Test of a Tuned Liquid Mass Damper Installed in a Real-scaled Structure,” Journal of the Computational Structurel Engineering Institute of Korea, Vol. 21, No. 2, pp. 161-168
- The Math Works, 1999, Optimization Toolbox User's Guide, The MathWorks
-
The Math Works, Inc, 2007, Simulink Reference, MATLAB
${\circledR}$ SIMULINK${\circledR}$ -
The Math Works, Inc, 2007, Real-time Windows Target 3 User's Guide, MATLAB
${\circledR}$ SIMULINK${\circledR}$
피인용 문헌
- Sloshing characteristics of an annular cylindrical tuned liquid damper for spar-type floating offshore wind turbine vol.47, pp.3, 2013, https://doi.org/10.12989/sem.2013.47.3.331
- Characterisation of instantaneous dynamic parameters in vibration analysis of tuned liquid column dampers vol.90, pp.1, 2017, https://doi.org/10.1007/s11071-017-3690-z