DOI QR코드

DOI QR Code

A Scalable Wireless Body Area Network for Bio-Telemetry

  • Saeed, Adnan (Quality of Life Technology Laboratory, The University of Texas at Dallas) ;
  • Faezipour, Miad (Quality of Life Technology Laboratory, The University of Texas at Dallas) ;
  • Nourani, Mehrdad (Quality of Life Technology Laboratory, The University of Texas at Dallas) ;
  • Banerjee, Subhash (VA North Texas Healthcare System and University of Texas Southwestern Medical Center) ;
  • Lee, Gil (Quality of Life Technology Laboratory, The University of Texas at Dallas) ;
  • Gupta, Gopal (Quality of Life Technology Laboratory, The University of Texas at Dallas) ;
  • Tamil, Lakshman (Quality of Life Technology Laboratory, The University of Texas at Dallas)
  • Published : 2009.06.30

Abstract

In this paper, we propose a framework for the real-time monitoring of wireless biosensors. This is a scalable platform that requires minimum human interaction during set-up and monitoring. Its main components include a biosensor, a smart gateway to automatically set up the body area network, a mechanism for delivering data to an Internet monitoring server, and automatic data collection, profiling and feature extraction from bio-potentials. Such a system could increase the quality of life and significantly lower healthcare costs for everyone in general, and for the elderly and those with disabilities in particular.

Keywords

References

  1. Department of Health and Human Services, http://www.aoa.gov, 2007
  2. J. Rabaey, M. Ammer, J. Silva, D. Patel and S. Roundy, 'Picoradio Supports Ad-Hoc Ultra-Low Power Wireless Networking,' IEEE Computers, pp.42-48, July, 2000 https://doi.org/10.1109/2.869369
  3. American Heart Association, http://www.americanheart.org, July, 2007
  4. R. Fensli, E. Gunnarson and T. Gundersen, 'A Wearable ECG-Recording System for Continuous Arrhythmia Monitoring in a Wireless Tele-Home-Care Situation,' Proceedings of the 18th IEEE Symposium on Computer-Based Medical Systems, pp.407-412, 2005 https://doi.org/10.1109/CBMS.2005.22
  5. Z. Tafa and R. Stojanovic, 'Bluetooth-Based Approach to Monitoring Biomedical Signals,' Proceedings of the 5th WSEAS International Conference on Telecommunications and Informatics, pp.415-420, May, 2006
  6. B. Lo, S. Thiemjarus, R. King and G. Yang, 'Body Sensor Network: A Wireless Sensor Platform for Pervasive Healthcare Monitoring,' http://www.nextwaveinterface.org.uk/centers/UbiCare/, 2007
  7. V. Shnayder, B. Chen, K. Lorincz, T. Fulford Jones and M. Welsh, 'Sensor Networks for Medical Care,' Technical Report TR-08-05, Division of Engineering and Applied Sciences, Harvard University, 2005
  8. D. Lymberopoulos, A. Savvides, 'XYZ: A Motion- Enabled, Power Aware Sensor Node Platform for Distributed Sensor Network Applications,' IEEE Intl. Symposium on Information Processing in Sensor Networks, pp.449-454, Apr., 2005
  9. S. Park, I. Locher, A. Savvides, M. B. Srivastava, A. Chen, R. Muntz, S. Yuen, 'Design of a Wearable Sensor Badge for Smart Kindergarten,' IEEE Intl. Symposium on Wearable Computers, pp.231-238, 2002
  10. M. Welsh, 'CodeBlue: Wireless Sensor Networks for Medical Care,' Harvard University, www.eecs. harvard.edu/~mdw/proj/codeblue/
  11. E. M. Tapia, N. Marmasse, S. S. Intille, and K. Larson, 'MITes: Wireless Portable Sensors for Studying Behavior,' In Adjunct Proceedings of the Ubicomp 2004, 2004
  12. Benny Lo, Guang-Zhong Yang, 'Architecture for Body Sensor Networks,' IEEE Conference on Perspective in Pervasive Computing, pp.23-28, Oct., 2005
  13. MicaZ Datasheet, http://www.crossbow.com
  14. iMote2 Datasheet, http://www.intel.com
  15. J. Pan and W. J. Tompkins, 'A Real-Time QRS Detection Algorithm,' in IEEE Transactions on Biomedical Engineering, Vol.32, No.3, pp.230-236, Mar. 1985 https://doi.org/10.1109/TBME.1985.325532
  16. LabVIEW for ECG Signal Processing, http://zone.ni.com/devzone/cda/tut/p/id/6349
  17. MIT-BIH Arrhythmia Database, www.physionet.org/physiobank/database/mitdb
  18. F. Zhang, J. Tan, and Y. Lian, 'An Effective QRS Detection Algorithm for Wearable ECG in Body Area Network,' in Proc. of the IEEE Biomedical Circuits and Systems Conference, pp.195-199, 2007
  19. H.-Y. Zhou and K.-M. Hou, 'Embedded Real-Time QRS Detection Algorithm for Pervasive Cardiac Care System,' in Proc. of the 9th IEEE International Conference on Signal Processing, pp.2150-2153, 2008
  20. I.A Dotsinsky and T.V Stoyanov, 'Ventricular Beat Detection in Single Channel Electrocardiograms,' BioMedical Engineering OnLine, 2004

Cited by

  1. A Device for Wireless Transmission of Electrocardiographic and Electroencephalographic Data vol.45, pp.6, 2012, https://doi.org/10.1007/s10527-012-9245-1
  2. Adjusting Control Packet Transmission Intervals in Low Power Sensor Systems vol.10, pp.8, 2014, https://doi.org/10.1155/2014/139682
  3. Accuracy Improvement Methode of Step Count Detection Using Variable Amplitude Threshold vol.2, pp.6, 2013, https://doi.org/10.3745/KTCCS.2013.2.6.257
  4. A Patient-Adaptive Profiling Scheme for ECG Beat Classification vol.14, pp.5, 2010, https://doi.org/10.1109/TITB.2010.2055575