References
- 한국지진공학회, 도시철도 내진설계기준, 건설교통부, 1999
- 건설교통부, 지하공동구 내진설계기준, 2004. 6
- Luo, X., Muronoa, Y. and Nishimura, A., ''Verifying adequacy of the seismic deformation method by using real examples of earthquake damage', Soil Dynamics and Earthquake Engineering, Vol. 22, No.1, 2002, pp. 17-28 https://doi.org/10.1016/S0267-7261(01)00053-7
- Kawashima, K., 'Seismic analysis of underground structures', Journal of Disaster Research, Vol. 1, No.3, 2006
- Katayama, Ikuo, Studies on Fundamental Problems in Seismic Design Analyses of Critical Structures and Facilities, 1990
- Katayama, I. et. al, 'Proposal of the 'Response Seismic Coefficient Method' a practical quasi-static analysis method for structures buried underground', Fortieth Annual Technical Conference of the JSCE, Part 1, 1998, pp. 737-738 (in Japanese)
- Katayama, I., Adachi, M., Shimada, M., and Tsuzuki, T., On the practical analysis method for design analysis of buried structures, 19th Annual Meeting of Japan Society of Soil and Foundation, Abstracts, pp. 1445-1448, June, 1984 (in Japanese)
- Katayama, I., Adachi, M., Shimada, M., Tsuzuki, T., and Seshimo, Y., A quasi-static analysis method for buried structures - A proposal of 'Response Acceleration Method', Abstracts, 40th Annual Meeting of Japan Society of Civil Engineers, Part 1, pp. 737-738, Sept., 1985 (in Japanese)
- JSCE, Study on the evaluation of foundation - The study on the standardization of evaluation methodology of foundation, 1984
- Tohma, J. et al, Model experiment of sea water intake duct of nuclear power plant, Demyoku doboku, No. 197, pp. 36-44, July, 1985 (in Japanese)
- Tsuneo, O. and Kenichi, Y., 'Simplified analysis based on non-linear seismic coefficient method for sewage facilities', Nippon Koei Technical Forum, Vol. 9, 2000 (in Japanese)
- Unjoh, S., Hoshikuma, J., Nagaya, K. and Suzuki, T., 'Development of seismic isolation technology for underground structures and the application', Proc. of the 32th Joint Meeting of the U.S.-Japan Cooperative Program in Natural Resources Panel on Wind and Seismic Effects, 2001, pp. 239-252
- Unjoh, S., Hoshikuma, J., Nagaya, K. and Suzuki, T., Proc. of the 32th Joint Meeting of the U.S.-Japan Cooperative Program in Natural Resources Panel on Wind and Seismic Effects, 1998, pp. 211-223
- Shahidia, A.R. and Vafaeianb, M., 'Analysis of longitudinal profile of the tunnels in the active faulted zone and designing the flexible lining (for Koohrang-III tunnel)', Tunnelling and Underground Space Technology, Vol. 20, No.3, 2005, pp. 213-221 https://doi.org/10.1016/j.tust.2004.08.003
- Suzuki, T., Takatori, I., Okada, I. and Hagiwara, R., 'New seismic isolation design for urban tunnels in consideration of slip and its application to an actual shield-driven tunnel', Congress Proceedings CD-ROM, AITES - ITA Downunder 2002, 28th World Tunnel Congress, Sydney, Australia, 2002
- Ariman, T. and Muleski, G.E., 'A review of the response of buried pipelines under seismic excitations', Earthquake Engineering & Structural Dynamics, Vol. 9, No.2, 2006, pp. 133-152 https://doi.org/10.1002/eqe.4290090204