Abstract
In this paper, the signal analysis of eddy current array probe was performed to analyze the electromagnetic characteristics with the variation of FBH(flat bottomed hole) defects size on steam generator tube in NPP(nuclear power plants) using the electromagnetic finite element method. To obtain the electromagnetic characteristic of probes, the governing equation was derived from Maxwell's equations, and the individual problem was analyzed by using the 3-dimensional finite element method. For the simulation FBH defects were used. The depth of FBH defects were 20%, 40%, 60%, 80% and 100% of steam generator(SG) tube thickness, and it was assumed that the defects were located on the tube outside. And the operation frequencies of 100 kHz, 300 kHz and 400 kHz were used. Material of specimen was Inconel 600 which is usually used for SG tubes in NPP. The signal difference could be observed according to the size variation of depth of FBH defects and operation frequencies. The results in this paper can be helpful when the ECT(eddy current testing) signals from EC array probe are evaluated and analyzed.
본 논문에서는 전자기 유한요소 해석을 통하여 원전 증기발생기(SG, steam generator) 세관의 결함 크기 변화에 따른 배열 와전류 프로브의 와전류탐상 특성을 해석하였다. 프로브의 전자기적 특성을 해석하기 위하여 맥스웰 방정식을 이용하여 지배방정식을 유도하였고, 이를 3차원 전자기 유한요소법을 이용하여 문제를 해석하였다. 해석을 위해 선정한 결함은 평저공(FBH, flat bottomed hole) 결함을 선정하였다. FBH결함에 대해 결함의 위치를 관의 외부표면에 존재하게 하고 결함의 깊이는 세관 두께의 20%, 40%, 60%, 80%, 100%로 하였다. 또한 결함의 크기변화 및 시험주파수를 100 kHz, 300 kHz, 400 kHz로 변화시켜 해석하였다. 해석 대상으로는 원자력발전소 증기발생기 세관으로 사용되고 있는 Inconel 600 도체관을 사용하였다. 본 논문을 통하여 결함형상, 깊이 및 크기, 시험주파수의 변화에 따른 탐상신호의 변화를 확인할 수 있었다. 본 논문의 결과는 배열 와전류 프로브의 와전류탐상 신호 평가시 도움이 될 것이다.