Abstract

Low rise building roofs can be subjected to large fluctuating pressures during a tropical cyclone resulting in fatigue failure of cladding. Following the damage to housing in Tropical Cyclone Tracy in Darwin, Australia, the Darwin Area Building Manual (DABM) cyclic loading test criteria, that loaded the cladding for 10000 cycles oscillating from zero to a permissible stress design pressure, and the Experimental Building Station TR440 test of 10200 load cycles which increased in steps to the permissible stress design pressure, were developed for assessing building elements susceptible to low cycle fatigue failure. Recently the 'Low-High-Low' (L-H-L) cyclic test for metal roofing was introduced into the Building Code of Australia (2007). Following advances in wind tunnel data acquisition and full-scale wind loading simulators, this paper presents a comparison of wind-induced cladding damage, from a "design" cyclone proposed by Jancauskas, et al. (1994), with current test criteria developed by Mahendran (1995). Wind tunnel data were used to generate the external and net pressure time histories on the roof of a low-rise building during the passage of the "design" cyclone. The peak pressures generated at the windward roof corner for a tributary area representative of a cladding fastener are underestimated by the Australian/New Zealand Wind Actions Standard. The "design" cyclone, with increasing and decreasing wind speeds combined with changes in wind direction, generated increasing then decreasing pressures in a manner similar to that specified in the L-H-L test. However, the L-H-L test underestimated the magnitude and number of large load cycles, but overestimated the number of cycles in the mid ranges. Cladding elements subjected to the L-H-L test showed greater fatigue damage than when experiencing a five hour "design" cyclone containing higher peak pressures. It is evident that the increased fatigue damage was due to the L-H-L test having a large number of load cycles cycling from zero load (R=0) in contrast to that produced during the cyclone.

Keywords

References

  1. Amzallag, C., Gerey, J.P., Robert, J.L. and Bahuaud, J. (1994), "Standardization of the Rainflow Counting Method for Fatigue Analysis", Int. J. Fatigue, 16, 287-293. https://doi.org/10.1016/0142-1123(94)90343-3
  2. Australian Building Codes Board (2007), BCA 2007: Building Code of Australia, Australian Building Codes Board, Canberra ACT, Australia.
  3. Beck, V.R. and Stevens, L.K. (1979), "Wind loading failures of corrugated roof cladding", Institution of Engineers Australia Civil Engineering Transactions, CE21(1), 45-56
  4. Darwin Reconstruction Commission (1976), Darwin Area Building Manual, Darwin, Australia.
  5. Experimental Building Station (1978), Technical Record 440: Guidelines for the testing and evaluation of products for cyclone prone areas, Sydney, Australia.
  6. Ginger, J.D. (2001), "Characteristics if wind loads on roof cladding and fixings", Wind Struct., 4(1), 73-84. https://doi.org/10.12989/was.2001.4.1.073
  7. Ginger, J.D. and Henderson, D.J. (2003), "Wind loads on roof cladding and fixings", 10th Australian Wind Engineering Workshop, Sydney.
  8. Ginger, J.D., Henderson, D.J., Leitch, C. and Boughton, G.N. (2007), "Tropical Cyclone Larry: Estimation of wind field and assessment of building damage", Aust. J. Struct. Eng., 7, 209-224. https://doi.org/10.1080/13287982.2007.11464977
  9. Ginger, J.D., Holmes, J.D. and Kopp, G.A. (2008), "Effect of building volume and opening size on fluctuating internal pressure", Wind Struct., 11(5), 361-376. https://doi.org/10.12989/was.2008.11.5.361
  10. Harper, B.A., Kepert, J.D. and Ginger, J.D. (2008), "Guidelines for converting between various wind averaging periods in tropical cyclone conditions", Report submitted to World Meteorological Organization.
  11. Henderson, D.J. and Ginger, J.D. (2005), "Fatigue failure of roof components subjected to wind loading", Australian Structural Engineering Conf., Newcastle.
  12. Henderson, D.J., Ginger, J.D. and Reardon, G.F. (2001), "Performance of light gauge metal roof cladding subjected to cyclonic wind loading - A review", Australasian Wind Engineering Society Workshop, Townsville.
  13. Ho, T.C.E., Surry, D., Morrish, D. and Kopp, G.A. (2005), "The UWO contribution to the NIST aerodynamic database for wind loads on low buildings: Part 1. Archiving format and basic aerodynamic data", J. Wind Eng. Ind. Aerod., 93, 1-30. https://doi.org/10.1016/j.jweia.2004.07.006
  14. Holmes, J.D. (2002), "Fatigue under along-wind loading-closed-form solutions", Eng. Struct., 24, 109-114. https://doi.org/10.1016/S0141-0296(01)00073-6
  15. Jancauskas, E.D., Mahendran, M. and Walker, G.R. (1994), "Computer simulation of the fatigue behaviour of roof cladding during the passage of a tropical cyclone", J. Wind Eng. Ind. Aerod., 51, 215-227. https://doi.org/10.1016/0167-6105(94)90005-1
  16. Kopp, G.A., Morrison, M.J., Iizumi, E., Henderson, D. and Hong, H.P. (2008), "The 'Three Little Pigs' Project: Hurricane Risk Mitigation by Integrated Wind Tunnel and Full-Scale Laboratory Tests", submitted to ASCE Nat. Hazards (September, 2008).
  17. Kumar, K.S. and Stathopoulos, T. (1998), "Fatigue analysis of roof cladding under simulated wind loading", J. Wind Eng. Ind. Aerod., 77-8, 171-183. https://doi.org/10.1016/S0167-6105(98)00141-X
  18. Madayag, A. (1969), Metal Fatigue: Theory and design, Wiley & Sons, New York.
  19. Mahendran, M. (1990), "Fatigue behaviour of corrugated roofing under cyclic wind loading", Civil Engineering Transactions, I. E. Aust.
  20. Mahendran, M. (1993), "Simulation of Cyclonic Wind Forces on Roof Claddings by Random Block Load Testing", Cyclone Testing Station Technical Report No. 38, James Cook University.
  21. Mahendran, M. (1995), "Towards an Appropriate Fatigue Loading Sequence for Roof Claddings in Cyclone Prone Areas", Eng. Struct., 17, 476-484. https://doi.org/10.1016/0141-0296(95)00049-D
  22. Morgan, J. and Beck, V. (1977), "Failure of sheet metal roofing under repeated wind loading", Civil Engineering Transactions, I. E. Aust.
  23. Oh, J.H., Kopp, G.A. and Inculet, D.R. (2007), "The UWO contribution to the NIST aerodynamic database for wind loads on low buildings: Part 3. Internal pressures", J. Wind Eng. Ind. Aerod., 95, 755-779. https://doi.org/10.1016/j.jweia.2007.01.007
  24. Smith, R.N.L. (1991), Basic fracture mechanics, Oxford, Butterworth-Heinemenn.
  25. St. Pierre, L.M., Kopp, G.A., Surry, D. and Ho, T.C.E. (2005), "The UWO contribution to the NIST aerodynamic database for wind loads on low buildings: Part 2. Comparison of data with wind load provisions", J. Wind Eng. Ind. Aerod., 93, 31-59. https://doi.org/10.1016/j.jweia.2004.07.007
  26. Standards Australia (1992), Methods of testing sheet roof and wall cladding - Resistance to wind pressures for cyclone regions, AS-4040.3:1992, Standards Australia, Sydney NSW, Australia.
  27. Standards Australia (2002), Structural design actions - Part 2: Wind actions, AS/NZS-1170.2:2002, Standards Australia, Sydney NSW, Australia.
  28. Walker, G.R. (1975), Report on Cyclone Tracy - Effect on buildings - Dec 1974, Australian Dept of Housing and Construction.
  29. Xu, Y.L. (1993), "Wind Induced Fatigue Loading on Roof Cladding of Low-Rise Buildings", Cyclone Testing Station Technical Report, Townsville, James Cook University.
  30. Xu, Y.L. (1995), "Fatigue Performance of Screw-Fastened Light-Gauge-Steel Roofing Sheets", J. Struct. Eng. ASCE, 121, 389-398. https://doi.org/10.1061/(ASCE)0733-9445(1995)121:3(389)

Cited by

  1. Storm and Gust Duration Effects on Design Wind Loads for Glass vol.137, pp.12, 2011, https://doi.org/10.1061/(ASCE)ST.1943-541X.0000397
  2. Full-scale testing of low-rise, residential buildings with realistic wind loads vol.104-106, 2012, https://doi.org/10.1016/j.jweia.2012.01.004
  3. Water penetration resistance of residential window and wall systems subjected to steady and unsteady wind loading vol.46, pp.7, 2011, https://doi.org/10.1016/j.buildenv.2010.12.008
  4. Current and Future Directions for Wind Research at Western: Disaster Mitigation and the 'Three Little Pigs' Project vol.35, pp.4, 2010, https://doi.org/10.5359/jawe.35.282
  5. Response of pierced fixed corrugated steel roofing systems subjected to wind loads vol.33, pp.12, 2011, https://doi.org/10.1016/j.engstruct.2011.08.020
  6. Response of toe-nailed, roof-to-wall connections to extreme wind loads in a full-scale, timber-framed, hip roof vol.56, 2013, https://doi.org/10.1016/j.engstruct.2013.07.001
  7. Probabilistic procedure for wood-frame roof sheathing panel debris impact to windows in hurricanes vol.35, 2012, https://doi.org/10.1016/j.engstruct.2011.11.009
  8. Unified static-fatigue pull-through capacity equations for cold-formed steel roof battens vol.139, 2017, https://doi.org/10.1016/j.jcsr.2017.09.027
  9. “Three Little Pigs” Project: Hurricane Risk Mitigation by Integrated Wind Tunnel and Full-Scale Laboratory Tests vol.11, pp.4, 2010, https://doi.org/10.1061/(ASCE)NH.1527-6996.0000019
  10. Development and validation of a numerical model for steel roof cladding subject to static uplift loads vol.17, pp.5, 2013, https://doi.org/10.12989/was.2013.17.5.495
  11. Wind storm loss estimations in the Canton of Vaud (Western Switzerland) vol.12, pp.12, 2009, https://doi.org/10.5194/nhess-12-3789-2012
  12. Uplift Capacity of Light-Frame Rafter to Top Plates Connections Applied with Elastomeric Construction Adhesives vol.32, pp.5, 2009, https://doi.org/10.1061/(asce)mt.1943-5533.0003152