DOI QR코드

DOI QR Code

The Study of Optimum Design of Y-Channel Micro-Mixer by Using LIF Conforcal Microscope

LIF Conforcal Microscope을 이용한 Y-channel 마이크로믹서의 최적설계 연구

  • 김상우 (한양대학교 대학원 기계공학과) ;
  • 현석호 (한양대학교 대학원 기계공학과) ;
  • 신태석 (한양대학교 대학원 기계공학과) ;
  • 이도형 (한양대학교 기계정보공학부)
  • Published : 2009.05.01

Abstract

Due to extremely small device size and velocity scale, mixing in microchannel take place very slowly by way of molecular diffusion transport. Mixing enhancement becomes a central issue in microfluidics for biomedical and chemical applications. In this work, The optimization results and validation through experiment and fabrication. In this efficient micromixer design, it is essential to evaluate mixing efficiency with good precision. Mixing efficiency for Y-channel micromixer is measured by fluorescence intensity using LIF(Laser Induced Fluorescence) Confocal Microscope. The Y-channel micromixers are fabricated with polydimethylsiloxane(PDMS). Nile Blue A is injected into the micromixer as a fluorescence dye for measuring of fluorescence intensity by He/Ne laser. Throughout the experiments and computer simulation, accurate mixing efficiency evaluation process for a PDMS Y-channel micromixer is established.

Keywords

References

  1. Stroock, A. D., Dertinger, S. K. W, Ajdari, A., Mezic, I., Stone, H. A. And Whitesides, G. M., 2002, 'Chaotic Mixer for Microchannel,' Science, Vol. 295, pp. 647-651 https://doi.org/10.1126/science.1066238
  2. Nguyen, N. T. and Wereley, S. T., 2002, 'Fundamentals and Applications of Microfluidics,' Artech House, Boston, pp. 386-401
  3. Yang, Z., Goto, H., Matsumoto, M. and Maeda, R., 2002, 'Active Micromixer for Microfluidic Systems using Lead-Zirconate-Titanate(PZT)-Generated Ultra-sonic Vibration,' Electrophoresis, Vol. 21, Issue1, pp. 116-119 https://doi.org/10.1002/(SICI)1522-2683(20000101)21:1<116::AID-ELPS116>3.0.CO;2-Y
  4. Knight, J. B., Vishwanath, A., Brody, J. P. and Austin, R.H., 1998, 'Hydrodynamic Focusing on a Silicon Chip: Mixing Nanoliters in Microseconds,' Phys. Rev. Lett., Vol. 80, No. 17, pp. 3863-3866 https://doi.org/10.1103/PhysRevLett.80.3863
  5. Wolfgang, E., Volker, H. and Holger, L., 2002, 'Microreactors,' Wiley, Newyork, pp. 41-85
  6. Schwesinger, N., Frank, T. and Wurmus, H., 1996, 'A Modular Microfluid System with an integrated Micromixer,' J. Micromech. Microeng., Vol. 6, pp. 99-102 https://doi.org/10.1088/0960-1317/6/1/023
  7. Koch, M., Chatelain, D., Evans, A. G. R. and Brunnschweiler, A., 1998, 'Two Simple Micromixers Based on Silicon,' J. Micromech. Microeng., Vol. 8, pp. 123-126 https://doi.org/10.1088/0960-1317/8/2/020
  8. Wang, H., Iovenitti, P., Harvey, E. and Masood, S., 2002, 'Optimizing Layout of Obstacles for Enhanced Mixing in Microchannels,' Smart Materials and Structures, Vol. 11, pp. 662-667 https://doi.org/10.1088/0964-1726/11/5/306
  9. Wong, S. H., Ward, M. C.L. and Wharton, C. W., 2004, 'Micro T-mixer as a Rapid Mixing Micromixer,' Sensors and Actuators B, Vol. 100, pp. 359-379 https://doi.org/10.1016/j.snb.2004.02.008
  10. Choi, J. W., Choi, H. I., Lee, D. H. and Lee, D., 2005, 'Study on Mixing Enhancement of a Y-channel Micromixer with Obstacles,' Trans. of the KSME(B), Vol. 29, No. 12, pp. 1369-1376 https://doi.org/10.3795/KSME-B.2005.29.12.1369
  11. Shin, Y. S., Choi, H. I., Lee, D. H. and Lee, D., 2006, 'Optimum Design of a Y-channel Micromixer for Enhanced Mixing,' Trans. of the KSME(A), Vol. 30, No. 3, pp. 302-309 https://doi.org/10.3795/KSME-A.2006.30.3.302
  12. Ryu, K. S., Liu, C., 2002, 'Precision Patterning of PDMS Thin Films : A New Fabrication Method and Its Applications,' Micro Total Analysis Systems, Vol. 1, pp. 112-114
  13. Yoon, S. Y. and Kim, K. C., 2006, 'Signal Intensity Enhancement of m-LIF by Using Ultra-Thin Laser Sheet Illumination and Aqueous Mixture with Ethanol/Methanol for Micro-Channel Application,' Optics and Lasers in Eng., Vol. 44, pp. 224-239 https://doi.org/10.1016/j.optlaseng.2005.04.001