Study on Flame Height Equation for the Pinus densiflora Surface Fuel Bed

소나무 낙엽층 화염높이 산정식에 관한 연구

  • 김동현 (국립산림과학원 산림방재연구과)
  • Published : 2009.12.31

Abstract

Flame height calculation in a forest fire is a crucial part of predicting horizontal or vertical flame spread flared by radiation heat transfer. Flame height, which is one of the flame characteristics, can be estimated by the average height of luminous flame. This research relied on flame height observation test on P. densiflora surface fuel bed, which are surface combustibles in a forest, and calorimeter to measure Heat Release Rate, thus produced $H_f=0.027(\dot{Q'})^{2/3}$, flame height calculation equation for surface fuel. The research did not take into consideration such conditions as external velocity, slope and other variables that could affect flame height. According to comparison among experiment results, calculation results of the above formula and those of existing Heskestad formula (1998), it was found that standard error in fallen pine needles between experimental results and calculation results of the above formula amounts to 0.08, whereas standard error in same plant between experimental results and calculation results of existing Heskestad formula amounts to 0.23.

산불에서의 화염높이 산정은 복사열전달에 의한 수평 또는 수직적 화염확산을 예측하는데 있어 매우 중요한 부분이다. 화염특성 중 화염높이는 빛을 수반하는 화염(the luminous flame)의 평균높이로 확인할 수 있다. 본 연구에서는 외부 풍속과 경사 등으로 인한 화염 높이가 변화될 수 있는 조건을 제외한 산림내 지표연소물질(surface fuel)인 소나무 낙엽층(fuel bed)에 대한 화염높이 관측실험과 열량분석계을 이용하여 발열량(Heat Release Rate) 측정실험과 수치해석을 통해 지표연소물질에 대한 화염높이 산출식 $H_f=0.027(\dot{Q'})^{2/3}$을 도출하였다. 실험값과 개발 산정식, 기존 Heskestad 식과의 적용값 비교 결과, 소나무 낙엽의 경우, 실험값과 개발 산정식 적용값의 표준오차는 0.08, 실험값과 기존 Heskestad 식의 표준오차는 0.23으로 개발 산정식의 정확성이 높은 것으로 나타났다.

Keywords

References

  1. 김장환, 김응식, 박형주, 이명보, 김동현, '지표화 연료의 열량분석에 관한 실험방법 연구', 한국화재소방학회 논문지, Vol.22, No.3, pp.258-264 (2008)
  2. 김동현, 이명보, 강영호, 이시영, '지표물질 착화성 실험을 통한 발화위험성 분석', 한국방재학회 학술발표대회 논문집, pp.379-384(2006)
  3. 박형주, 김응식, 김장환, 김동현, '복사열을 이용한 소나무와 굴참나무 낙엽의 연소특성 분석', 한국화재소방학회 논문지, Vol.21, No.3, pp.33-41(2007)
  4. 김동현, 田中哮義, 이명보, 김광일, '낙엽층 화염높이산정에 관한연구', 2009년도 춘계학술논문발표회 논문집,한국화재소방학회, pp.365-371(2009)
  5. F.A. Albini, 'A Model for the Wind-blown Flame from a Line Fire', Combust. Flame, Vol.43, pp.155-174(1981) https://doi.org/10.1016/0010-2180(81)90014-6
  6. R.M. Nelson, Jr. and C.A. Adkins, 'Flame Characteristics of Wind-driven Surface Fires', Can. J. For. Res., Vol.16, pp.1293-1300(1986) https://doi.org/10.1139/x86-229
  7. R.C. Rothermel, 'A Mathematical Model for Predicting Fire Spread in Wildland Fuels', USDA Forest Sterv. Intermountain Forest and Range Exp. Stn. Res. Pap. INT-115(1972)
  8. W. Anderson, E. Paster, B. Butler, E. Catchpole, J.L. Dupuy, P. Fernandes, M. Guijarro, J.-M. Mendes-Lopes, and J. Venture, 'Evaluating Models to Estimate Flame Characteristics for Free-burning Fires using Laboratory and Field Data', V International Conference on Forest Fire Research (2006)
  9. E.E. Zukoski, 'Fire Safety Science-Proceedings of the First International Symposium', Hemisphere, New York(1984)
  10. E.E. Zukoski, B.M. Cetegen, and T. Kubota, 20th Symposium on Combustion, Combustion Institute, Pittsburgh, PA(1985)
  11. E.E. Zukoski, B.M. Cetegen, and T. Kubota, Visible Structure of Buoyant Diffusion Flames, 20th Symposium on Combustion, Combustion Institute, Pittsburgh, PA, pp.361-366(1984)
  12. J.G. Quintiere and B.S. Grove, 'Correlations for Fire Plumes', Department of fire protection Engineering University of Maryland College Park, MD 20742(1998)
  13. J.G. Quintiere and B.S. Grove, 'A Unified Analysis for Fire Plumes', Twenty-Seventh Symposium on Combustion/The Coumbustion Institute, pp.2757-2766(1998)
  14. G. Heskestad, Fire Safety Journal, Vol.30, p.215 (1998) https://doi.org/10.1016/S0379-7112(97)00035-0
  15. B. McCaffrey, 'The SFPE Handbook of Fire Protection Engineering', 2nd ed., Society of Fire Protection Engineers and National Fire Protection Association, Quincy, MA(1995)