Performance Analysis of an Indoor Heat Exchanger with R-410A for GHP Application

  • Lee, Jong-Ho (School of Mechanical Engineering, Kyung Hee University) ;
  • Kim, Sung-Soo (School of Mechanical Engineering, Kyung Hee University) ;
  • Cha, Woo-Ho (Air conditioning division, LS Mtron) ;
  • Kang, Yong-Tae (School of Mechanical Engineering, Kyung Hee University)
  • Published : 2009.12.31

Abstract

The objectives of this paper are to study the effects of thermal and geometric conditions on the performance of indoor heat exchangers with R-410A for Gas Engine Driven Heat Pump (GHP) application and to find the optimum design conditions of indoor heat exchangers by parametric analysis for the key parameters. The key parameters are number of tube row, number of tube pipe, fin pitch and transverse tube pitch. In the air side, moisture out of the humid air condenses on the fin surface while the refrigerant (R-410A) boils inside the smooth tube. Therefore this study uses Log Mean Enthalpy Difference (LMHD) method to analyze the heat transfer from the humid air to the refrigerant. This study determines the heat exchanger size, air side/refrigerant side pressure drop and overall heat transfer coefficient. Optimum design conditions for the key parameters are also determined by the parametric analysis. The results show that number of rows and pipes, fin pitch have significant effect on the heat exchanger size. It is also found that the tube length of the louver fin is $17{\sim}30%$ shorter than that of the plate fin.

Keywords

References

  1. Kattan, N., Thome, J. R., Favrat, 1998, Flow Boiling in Horizontal Tubes: Part 1 Development of a Diabetic Two-Phase Flow Pattern Map, Transaction of the ASME, Journal of Heat Transfer, Vol.120, pp.140-147 https://doi.org/10.1115/1.2830037
  2. Kim, M. H., Shin, S. J., Lim B. H., 1998, Evaporating Heat Transfer Characteristics of R22 and R410A in 9.52mm O.D. Smooth and Micro-fin Tube, Korean Society of Mechanical Engineers, Vol. 22, No.10, pp. 1454-1465
  3. Friedel, L., 1979, Improved friction pressure drop correlations for horizontal and vertical two phase pipe flow. In European Two Phase Flow Group Meeting, Italy
  4. Ma, X., Ding, G., Zhang, Y., Wang, K., 2007, Airside heat transfer and friction characteristics for enhanced fin-and-tube heat exchanger with hydrophilic coating under wet conditions, International of Refrigeration, Vol. 30, No.7, pp. 1153-1167 https://doi.org/10.1016/j.ijrefrig.2007.03.001
  5. Chang H. J., Kang B. H., Kim S., Park B. K., 2002, An experimental Study on heat transfer and Pressure drop of air side in a plate-louvered fin heat exchanger, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 14, No.6, pp. 485-492
  6. Wang, C. C., Chi, Y. Y., 2000, Heat transfer and friction characteristics of plain fin-and-tube heat exchangers, part II:Correlation, International Journal of Heat and Mass Transfer, Vol. 43, pp. 2693-2700 https://doi.org/10.1016/S0017-9310(99)00333-6
  7. Mclinden. M. O., Klein. S. A., Lemmon E. W., Peskin A. P. ., 2002, NIST Reference Fluids Ther-modynamic Properties-REFPROP, Ver. 7.0, National Institute of Standards and Technology, Gaithersburg, Maryland, U.S.A.
  8. ASHRAE, 1998, Fundamental Handbook(SI)