DOI QR코드

DOI QR Code

태안 시설원예단지의 온실 냉난방 부하 분석

Analyses of Heating and Cooling load in Greenhouse of Protected Horticulture Complex in Taean

  • 서원명 (경상대학교 농업생명과학대학 지역환경기반공학과 (농업생명과학연구원)) ;
  • 배용한 (경상대학교 농공학과 대학원) ;
  • 허해준 ((주)하이드로젠파워) ;
  • 곽철순 ((주)하이드로젠파워) ;
  • 이석건 (경북대학교 농업토목공학과) ;
  • 이종원 (경북대학교 농업토목공학과) ;
  • 윤용철 (경상대학교 농업생명과학대학 지역환경기반공학과 (농업생명과학연구원))
  • 발행 : 2009.11.30

초록

This study was conducted in the process that the basic plan of the formation of the thermal energy complex in the Iwon reclaimed land of Taean was being made. Targeting for the large-sized greenhouse to be made in this area, it examined the cooling and heating load and the amount of ventilation, and also analyzed the economic efficiency of heating. The research results are as per the below: The minimum ambient temperature of this area was measured on January 7, 2001, which was $-18.7^{\circ}C$, and the maximum ambient temperature of this area was measured on July 24, 1994, which was $36.7^{\circ}C$. The maximum heating load was 39,011 MJ/h, but the date when the maximum heating load was not consistent with the date when the minimum temperature was measured. The maximum cooling load was 88,562MJ/h, It was approximately 2.3 times of the maximum heating load, which was measured at 14:00 hours on September 4, 2000. The maximum amount of ventilation heat was 138,639MJ/h. Assuming the rate of solar heat use as 10%, 20%, 50%, and 100%, the total sum of cost-benefit would be ₩-193,450,000, ₩-634,930,000, ₩-3,372,960,000, and ₩-9,850,420,000, respectively 20 years later. The break-even point of the geothermal heat pump would be about 4 years for 10% use, about 3 years for 20% or 50% use, and approximately 6 years for 100% use. It was found that 50% use would be most advantageous. In case two systems are combined, the break-even point will be 10 years, 8 years, and 11 years respectively.

키워드

참고문헌

  1. Kim, H. T., 2007. Development method of the future agricultural complex in reclaimed land, 2-5. Gwacheon and Uiwang, Gyeonggi: Ministry of Agriculture and Forestry and Korea Rural Community Corporation (in Korean)
  2. Korea Energy Management Corporation New & Renewable Energy Center (KEMCNEC), New & Renewable Energy, Http://www.knrea.or.kr. Accessed 9 Mar. 2009
  3. Lee, S. G., 1997. Fundamental study on KUMI greenhouse complex planing, 1-4. KRCC. Uiwang, Gyeonggi, Korea (in Korean)
  4. Ministry for Food, Agriculture, Forestry and Fisheries (MFAFF), 2008a. Production results of vegetable crop in 2007, 52-64. Gwacheon, Korea (in Korean)
  5. Ministry for Food, Agriculture, Forestry and Fisheries (MFAFF), 2008b. Cultural state of floricultural crop in 2007, 3-13. Gwacheon, Korea (in Korean)
  6. Rural Development Administration (RDA), 2008. Guide book of energy cost down protected horticulture for overcome of high oil price, 126-218. Suwon, Korea (in Korean)