Study on Incineration Behavior of Heavy Oil Fly Ash for Valuable Metal Recovery

유가금속(有價金屬) 회수(回收)를 위한 중유회(重油灰)의 연소거동(燃燒擧動)에 관한 연구(硏究)

  • Published : 2009.02.27

Abstract

To design and construct a moving bed stoker incinerator for incineration treatment of the domestic oil fly ash, operating condition and moving bed area of incinerator were determined by performing incinerate experiment of the oil fly ash in the muffle furnace which simulates moving bed stoker incinerator in all conditions. Incineration process of the oil fly ash could be divided into 3 stages, every stage needs the appropriate operating condition for effective incineration. The optimum content of water in the heavy oil fly ash was found to be 20 wt% to prevent the ash from flying and reduce the volume. Science combustion rate of oil fly ash depends on the oxygen content, the incinerator must have a equipment to control the oxygen content in the combustion air. The optimum temperature was $750{\sim}800^{\circ}C$ in order to prevent adhesion to the stocker and evaporation of metal compounds of low melting point. Uniform combustion reaction and acceleration of combustion rate required agitation during the combustion of oil fly ash. The incineration rate was $12.53kg/m^2hr$ and the working area of moving bed incinerator was found to be $60m^2$ to incinerate 18 tons of oil fly ash per day.

중유회를 효율적으로 소각 처리할 수 있는 이동상식 스토카로를 설계, 제작하기 위해 중유회가 노상을 이동하면서 겪는 조건들을 회분식 노에서 모사(模寫)하여 열중량분석법으로 중유회의 소각실험을 수행하였다. 이 결과로부터 이동상식 스토카로의 운전조건 및 노상면적 등을 구하였다. 중유회의 연소과정은 연소속도 차이에 의해 3단계로 구별되며, 각 단계별로 효과적인 연소가 이루어질 수 있도록 해야 한다. 비산방지 및 체적감소를 위하여 소각 전 첨가되는 수분 함량은 20 wt.%가 적절하였다. 중유회의 연소속도는 산소농도에 크게 의존하므로, 소각로는 연소공기의 조절 기능이 필요하다. 저융점 금속화합물의 용착 및 증발을 방지하고, 소각잔사의 불용화 및 유가금속 회수를 위해 소각온도는 $750^{\circ}C{\sim}800^{\circ}C$가 적절하고, 중유회의 균일한 연소반응과 연소속도의 향상을 위해 소각 중 중유회의 교반이 요구된다. 최적 조건에서 단위면적당 소각속도는 $12.53kg/m^{2}hr$이며 1일 18 ton의 중유회를 소각처리하기 위해서는 $60m^2$의 노상면적이 필요하다.

Keywords

References

  1. 尹旿燮, 1992 : 最新廢棄物處理, p.49, 進路硏究社
  2. 産業技術情報院, 1991 : 産業廢棄物의 處理와 資源化 技術動向(調査硏究報告書 59號)
  3. T. Ono, K. Hoshizaki, and J. Suzuki, 1973 : 重油灰處理に關する基礎肑檢討その2 重油灰處却方法の檢討 電力中央研究所 技術苐一研究報告書, 研究報告:72120
  4. T. Ono, K. Hoshizaki, J. Suzuki, and Y. Ishihara,1973: 重油灰處却方法の檢討, 火力原子力發電, 24, p. 15
  5. 荒川義光, 1975 : NGK 移動床式重油灰燒却爐, 報告報告
  6. Adnan Aydin, 1988 : Recovery of Vanadium Compositions tram the Slags and Fly Ashes of Power Plants, Chimica Acta Turcica, 16, 155
  7. D. J. Eatough, N. L. Eatough, M. H. Hill, N. F. Mangelson, and L. D. Hansen, 1984: Identification of $VO_{2}^{+}$ in Particles from the Flue Lines of Oil-Fired Power Plants, Environ. Sci. Technol, 18, p. 124 https://doi.org/10.1021/es00122a714
  8. Y. Mamane, J. L. Miller, and Y. G Dzuhay, 1986: Characterization of Individual Fly Ash Participles Emitted from Coal- and Oil-Fired Power Plants, Atomospheric Environment, 20, p. 2125 https://doi.org/10.1016/0004-6981(86)90306-9
  9. Ishwar P. Murarka, 1987: Chemical Characterization of Fossil Fuel Combustion Wastes, Electr. Power. Rs. Inst. Rep. Epri. EA5321, p. 148
  10. G L. Fisher, K. L. McNeill, B. A. Prentice, C. J. Democko, A. R. McFarland, and G L. Finch, 1984: Comparison of Environmental Particulate Matter Derived From Stationary Sources, Particulate Science and Technology, 2, p. 75 https://doi.org/10.1080/02726358408906395
  11. 柳然太, 金炳圭, 崔榮允, 朴種鉉, 洪性雄, 黃善國, 1996 : 국내 중유회의 소각처리에 관한 기초 연구(I)', 한국폐기물학회지, 13(2), p. 236
  12. J. J. Moore, 1981: Chemical Metallurgy, Butterworths, London, p 181
  13. D. Kunii, and O. Levenspil, 1969: Fluidazation Engineering, p. 72, John Wiley & Sons. Inc., New York