References
- Addy M, West N. Etiology, mechanisms, and management of dentine hypersensitivity. Curr Opin Periodontol 2:71-77, 1994
- Walters PA. Dentinal hypersensitivity: a review. J Contemp Dent Pract 15:6(2):107-117, 2005
- Johnson GH, Gordon GE, Bales DJ. Postoperative sensitivity associated with posterior composite and amalgam restorations. Oper Dent 13(2):66-73, 1988
- Gordan VV, Mjor IA, Hucke RD, Smith GE. Effect of different liner treatments on postoperative sensitivity of amalgam restorations. Quintessence Int 30(1):55-59, 1999
- Grover PS, Hollinger J, Lorton L. A review of the incidence of pain after an operative treatment visit: Part I. J Prosthet Dent 51(2):224-225, 1984 https://doi.org/10.1016/0022-3913(84)90266-X
- Brannstrom M, Linden LA, Astrom A. The hydrodynamics of the dental tubule and of pulp fluid. A discussion of its significance in relation to dentinal sensitivity. Caries Res 1(4):310-317, 1967 https://doi.org/10.1159/000259530
- Brannstrom M, Linden LA, Johnson G. Movement of dentinal & pulpal fluid caused by clinical procedures. J Dent Res 47(5):679-682, 1968 https://doi.org/10.1177/00220345680470050201
- Brannstrom M. The hydrodynamic theory of dentinal pain: sensation in preparations, caries, and the dentinal crack syndrome. J Endod 12(10):453-457, 1986 https://doi.org/10.1016/S0099-2399(86)80198-4
- Pashley DH, Matthews WG, Zhang Y, Johnson M. Fluid shifts across human dentin in vitro in response to hydrodynamic stimuli. Arch Oral Biol 41(11):1065-1072, 1996 https://doi.org/10.1016/S0003-9969(96)00059-3
- Paphangkorakit J, Osborn JW. The effect of normal occlusal forces on fluid movement through human dentine in vitro. Arch Oral Biol 45(12):1033-1041, 2000 https://doi.org/10.1016/S0003-9969(00)00090-X
- Hashimoto M, Ito S, Tay FR, Svizero NR, Sano H, Kaga M, Pashley DH. Fluid movement across the resin-dentin interface during and after bonding. J Dent Res 83(11):843-848, 2004 https://doi.org/10.1177/154405910408301104
- Ratih DN, Palamara JE, Messer HH. Dentinal fluid flow and cuspal displacement in response to resin composite restorative procedures. Dent Mater 23(11): 1405-1411, 2007 https://doi.org/10.1016/j.dental.2006.11.029
- Ciucchi B, Bouillaguet S, Holz J, Pashley D. Dentinal fluid dynamics in human teeth, In vivo. J Endod 21(4):191-194, 1995 https://doi.org/10.1016/S0099-2399(06)80564-9
- Horiuchi H, Matthews B. In-vitro observations on fluid flow through human dentine caused by pain-producing stimuli. Arch Oral Biol. 18(2):275-294, 1973 https://doi.org/10.1016/0003-9969(73)90147-7
- Benenson W, Harris JW, Stocker H, Lutz H. Handbook of physics. New York: Springer; 2006
- Bausch JR, de Lange K, Davidson CL, Peters A, de Gee AJ. Clinical significance of polymerization shrinkage of composite resins. J Prosthet Dent 48(1):59-67, 1982 https://doi.org/10.1016/0022-3913(82)90048-8
- Pashley DH, Dynamics of the pulpo-dentin complex. Crit Rev Oral Biol Med 7(2):104-133, 1996 https://doi.org/10.1177/10454411960070020101
- Tay FR, Pashley DH, Suh BI, Carvalho RM, Itthagarun A. Single-step adhesives are permeable membranes. J Dent 30(7-8):371-382, 2002 https://doi.org/10.1016/S0300-5712(02)00064-7
- Tay FR, Pashley DH. Water treeing-a potential mechanism for degradation of dentin adhesives. Am J Dent 16(1):6-12, 2003
- Ozok AR, De Gee AJ, Wu MK, Wesselink PR. The influence of resin composite and bonded amalgam restorations on dentine permeability in Class II cavities in vitro. Dent Mater 17(6):477-484, 2001 https://doi.org/10.1016/S0109-5641(01)00004-5
- Hersek N, Canay S, Akca K, Ciftci Y. Comparison of microleakage properties of three different filling mate-rials. An autoradiographic study. J Oral Rehabil 29(12):1212-1217, 2002 https://doi.org/10.1046/j.1365-2842.2002.00972.x
- Murray PE, Hafez AA, Smith AJ, Cox CF. Bacterial microleakage and pulp inflammation associated with various restorative materials. Dent Mater 18(6):470-478, 2002 https://doi.org/10.1016/S0109-5641(01)00072-0
- Chersoni S, Suppa P, Grandini S, Goracci C, Monticelli F, Yiu C, Huang C, Prati C, Breschi L, Ferrari M, Pashley DH, Tay FR. In vivo and in vitro permeability of one-step self-etch adhesives. J Dent Res 83(6):459-464, 2004 https://doi.org/10.1177/154405910408300605
- Gregoire G, Guignes P, Millas A. Effect of self-etching adhesives on dentin permeability in a fluid flow model. J Prosthet Dent 93(1):56-63, 2005 https://doi.org/10.1016/j.prosdent.2004.10.008
- 이인복, 김민호, 김선영, 장주혜, 조병훈, 손호현, 백승호. 미세물 흐름 측정장치의 개발과 상아세관액의 수력학에의 응용. 대한치과보존학회지 33(2):141-147, 2008
Cited by
- Real-time measurement of dentinal fluid flow during desensitizing agent application vol.35, pp.5, 2010, https://doi.org/10.5395/JKACD.2010.35.5.313