A Study on Ultrasonic Image Diagnosis Methods of Tooth Defect with Phased-Array Techniques

위상배열기법을 이용한 치아결함 초음파이미지 진단기술개발

  • 오윤정 (전남대학교 치의학전문대학원 보존학교실) ;
  • 황인남 (전남대학교 치의학전문대학원 보존학교실) ;
  • 박수정 (전남대학교 치의학전문대학원 보존학교실) ;
  • 임광희 (우석대학교 기계자동차공학과) ;
  • 조현준 (품질기술안전원) ;
  • 조영태 (전주대학교 생산디자인공학과)
  • Published : 2009.12.15

Abstract

Recently, researches to develop phased array ultrasonic examination techniques are proceeded to diagnose dental caries and the status of surgical operation of dental implant. Sound field analysis of phased array ultrasonic transducers were carried out in order to characterizing the ultrasonic phased array beams. The sound field of ultrasonic radiation was calculated for the sample called "gypsum-improved stone" with the similar characteristics of dental materials. Industrial phased array ultrasonic devices were utilized for the insptriion of the artificial flaws machined in the gypsum-improved stone. Dental implants were made at the pig jaw bone and defect images were confirmed for the dental implants.

Keywords

References

  1. White, S. C., and Pharoah, M. J., 2004, "Oral radiology; principles and interpretation," 5th ed. St Louis: Mosby Inc, pp. 677-692.
  2. Lee, S. S., and Choi, S. C., 2005, "Radiographic examination for successful dental implant," Korean Journal of Oral and Maxillofacial Radiology, Vol. 35, pp. 63-68.
  3. Cucchiara, R., Lamma, E., and Sansoni, T., 2004, "An image analysis approach for automatically reorienteering CT images for dental implants," Computed Imaging Graph, Vol. 28, pp. 185-201.
  4. Tardieu, P. B., Vrielinck, L., and Escolano, E., 2003, "Computer-assisted implant placement. A case report: treatment of the mandible," Int J Oral Maxillofac Implants, Vol. 18, pp. 599-604.
  5. Macovski, A., 1979, "Ultrasonic Imaging Using Arrays," Proceedings of the IEEE, Vol. 67, No. 4, pp. 484-495.
  6. Kino, G. S., 1987, Acoustic Waves: Devices, Imaging, and Analog Signal Processing, Prentice-Hall, NJ.
  7. Shin, H. J, Song, S. J., and Jang, Y. H., 2000, "Nondestructive Inspection of Steel Structures Using Phased Array Ultrasonic Technique," Journal of the Korean Society for Nondestructive Testing, Vol. 20, No. 6, pp.538-544.
  8. Hwang, J. S., Shin, H. J., Song, S. J., and Song, T. K., 1999, "Digital Phased Array Ultrasonic Inspection system with Dynamic Focusing," 26th Review of Progress in Quantitative Nondestructive Evaluation, eds., D. O. Thompsonand D. E. Chimenti, Vol. 19A, pp. 1087-1093.
  9. Choi, S. W. and Lee, J. H., 1999, "Numerical Analysis of Ultrasonic Beam Profile Due to the Change of the Number of Piezoelectric Elements for Phased Array Transducer ," Journal of the Korean Society for Nondestructive Testing, Vol. 19 No. 3, pp. 207-216.
  10. L. W. Schmerr, Jr, 1999, Fundamentals of Ultrasonic Nondestructive Evaluation, A Modeling Approach, Plenum Press, New York, pp. 167-181.
  11. Schmerr, L. W. Jr, Sedov, A., and Lerch, T. P., 1997, "A boundary diffraction wave model for a spherically focused ultrasonic transducer," The Journal of the Acoustical Society of America, Vol. 101, pp. 1269-1277.
  12. Holm, S., 1998, "Bessel and Conical Beams and Approximation with Annular Arrays," IEEE Trans. Ultrason. Ferroelect., and Freq. Contr., Vol. 45, No. 3, pp. 712-718.
  13. Schwartz, J. L. and Steinburg, B. D., 1998, "Ultrasparse, Ultrawideband Arrays," IEEE Trans. Ultrason. Ferroelect., and Freq. Contr., Vol. 45, No. 2, pp. 376-393.
  14. Zhang, M. and Achenbach, J. D., 1999, "Simulation of self-focusing by an array on a crack in an immersed specimen," Ultrasonics, Vol. 37, pp. 9-18.
  15. Azar, L. and Whoo, S. C., 1999, "Experimental Characterization of Ultrasonic Phased Arrays for the Nondestructive Evaluation of Concrete Structures," Materials Evaluations, Vol. 57, No. 2, pp. 134-140.
  16. Whoo, S. C. and Shi, Y., 1998, "Optimization of Ultrasonic Phased Arrays," Review of Progress in Quantitative Nondestructive Evaluation, Vol. 17, pp. 883-890.
  17. Crombie, P., Bascom, Peter A. J., and Cobbold, Richard S. C., 1998, "Calculating the Pulsed Response of Linear Arrays: Accuracy Versus Computational Efficiency," IEEE Trans. Ultrason. Ferroelect., and Freq. Contr., Vol. 44, No. 5, pp. 997-1009.