참고문헌
- L. Clark and C. Lyons, 'Electrode systems for continuous monitoring cardiovascular surgεry', Ann. NY Acad. Sci. 102 (1962) 29 https://doi.org/10.1111/j.1749-6632.1962.tb13623.x
- S. J. Updike and J. P. Hicks, 'The enzyme electrode', Nature, 214 (1967) 986 https://doi.org/10.1038/214986a0
- N. Nakamura, H.-X. Huang, D.-J. Qian and J Miyake, 'Quartz Crystal Microbalance and Electrochemical Studies on a Viologen Thiol Incorporated in Phospholipid Self-Assembled Monolayers', Langmuir, 18 (2002) 5804 https://doi.org/10.1021/la020070e
- D.-Y. Lee, A.K.M. Kafi, S.-H. Park, D.-J. Qian, Y. -S. Kwon, 'Influence of Anions on Electrochemical Redox Reaction and Electrical Property using Violgen Derivative', Jpn. J. Appl. Phys. 45 (4B) (2006) 3772 https://doi.org/10.1143/JJAP.45.3772
- D.-Y. Lee, A.K.M. Kafi, S.-H. Park, Y. -S. Kwon, 'Charge Transfer Property of Self-Assembled Viologen Derivative by Electrochemical Quartz Crystal Microbalance Response', J. Nanosci. Nanotechnol., 6 (2006) 3657 https://doi.org/10.1166/jnn.2006.076
- A.K.M. Kafi, D.-Y. Lee, S.-H. Park, Y. -S. Kwon, 'Development of a peroxide biosensor made of a thiolated-viologen and hemoglobin-modified gold electrode', Microchem. J., 85 (2007) 308 https://doi.org/10.1016/j.microc.2006.07.007
- J.-Y. Ock, H.-K. Shin, Y. -S. Kwon, J. Miyake, 'Study on the electrochemical behavior of thε viologen monolayεrs by different chεmical structure', Colloid. Surface. A, 257 (2005) 351 https://doi.org/10.1016/j.colsurfa.2004.08.079
- D.-Y. Lee, W.-S. Choi, A.K.M. Kafi, S.-H. Park, Y. -S. Kwon, 'Immobilization, Hybridization and Amperometric Detection of DNA Sensor Using Quartz Crystal Microbalance', J. Nanosci. Nanotechnol. , 8 (2008) 4553 https://doi.org/10.1166/jnn.2008.IC21
- S. Hu, C.-C. Liu, 'Development of a hypoxanthine biosensor based on immobilized xanthine oxidase chemically modified electrode', Electroanal., 9 (1997) 372 https://doi.org/10.1002/elan.1140090504
- M. E. Ghica, Christopher M. A. Brett, 'A glucose biosensor using methyl viologen redox mεdiator on carbon film electrodes', Anal. Chim. Acta, 532 (2005) 145 https://doi.org/10.1016/j.aca.2004.10.058
- A.K.M. Kafi, F. Yin, H.-K. Shin, Y.-S. Kwon, 'Hydrogen peroxide biosensor based on DNA-Hb modified gold electrode', Thin Solid Films, 499 (2006) 420 https://doi.org/10.1016/j.tsf.2005.06.073
- A. I. Yaropolov, S. V. Shleev, O. V. Morozova, E. A. Zaitseva, G. Marko-Varga, J. Enmeus, L. Gorton, 'An Amperomεtric Biosensor Based on Laccase Immobilized in Polymer Matrices for Determining Phenolic Compounds', J. Anal. Chem. , 60 (2005) 553 https://doi.org/10.1007/s10809-005-0138-2
피인용 문헌
- Electrochemical detection of hydrogen peroxide via hemoglobin–DNA/pyterpy-modified gold electrode vol.9, pp.4, 2009, https://doi.org/10.1016/j.cap.2009.06.048
- Self-assembled monolayers (SAMs) for electrochemical sensing vol.15, pp.7-8, 2011, https://doi.org/10.1007/s10008-011-1493-6
- A Microfluidic Electrochemical Sensor for Detecting the Very Low Concentration Endocrine Disruptor with Self Assembled Monolayer and Preconcentration Technique vol.65, pp.4, 2016, https://doi.org/10.5370/KIEE.2016.65.4.628