참고문헌
- Ahn YH, Chen WM, Lee KY, Park KW, Lee SJ : Comparison of the load-sharing characteristics between pedicle-based dynamic and rigid rod devices. Biomed Mater 3 : 44101, 2008 https://doi.org/10.1088/1748-6041/3/4/044101
- Bellini CM, Galbusera F, Raimondi MT, Mineo GV, Brayda-Bruno M : Biomechanics of the lumbar spine after dynamic stabilization. J Spinal Disord Tech 20 : 423-429, 2007 https://doi.org/10.1097/BSD.0b013e318031af6f
- Gibson JN, Grant IC, Waddell G : The Cochrane review of surgery for lumbar disc prolapse and degenerative lumbar spondylosis. Spine (Phila Pa 1976) 24 : 1820-1832, 1999 https://doi.org/10.1097/00007632-199909010-00012
- Highsmith JM, Tumialan LM, Rodts GE Jr : Flexible rods and the case for dynamic stabilization. Neurosurg Focus 22 : E11, 2007
- Khoueir P, Kim KA, Wang MY : Classification of posterior dynamic stabilization devices. Neurosurg Focus 22 : E3, 2007
- Kim YS, Zhang HY, Moon BJ, Park KW, Ji KY, Lee WC, et al. : Nitinol spring rod dynamic stabilization system and Nitinol memory loops in surgical treatment for lumbar disc disorders: short-term follow up. Neurosurg Focus 22 : E10, 2007
- Kumar A, Beastall J, Hughes J, Karadimas EJ, Nicol M, Smith F, et al. : Disc changes in the bridged and adjacent segments after Dynesys dynamic stabilization system after two years. Spine (Phila Pa 1976) 33 : 2909-2914, 2008 https://doi.org/10.1097/BRS.0b013e31818bdca7
- La Grone MO : Loss of lumbar lordosis. A complication of spinal fusion for scoliosis. Orthop Clin North Am 19 : 383-393, 1988
- Lagrone MO, Bradford DS, Moe JH, Lonstein JE, Winter RB, Ogilvie JW : Treatment of symptomatic flatback after spinal fusion. J Bone Joint Surg Am 70 : 569-580, 1988
- Ledet EH, Carl AL, DiRisio DJ, Tymeson MP, Andersen LB, Sheehan CE, et al. : A pilot study to evaluate the effectiveness of small intestinal submucosa used to repair spinal ligaments in the goat. Spine J 2 : 188-196, 2002 https://doi.org/10.1016/S1529-9430(02)00182-1
- Markwalder TM, Wenger M : Dynamic stabilization of lumbar motion segments by use of Graf ’s ligaments : results with an average follow-up of 7.4 years in 39 highly selected, consecutive patients. Acta Neurochir (Wien) 145 : 209-214; discussion 214, 2003 https://doi.org/10.1007/s00701-002-1056-9
- McAfee PC : Interbody fusion cages in reconstructive operations on the spine. J Bone Joint Surg Am 81 : 859-880, 1999
- Rigby MC, Selmon GP, Foy MA, Fogg AJ : Graf ligament stabilisation : mid- to long-term follow-up. Eur Spine J 10 : 234-236, 2001 https://doi.org/10.1007/s005860100254
- Rohlmann A, Burra NK, Zander T, Bergmann G : Comparison of the effects of bilateral posterior dynamic and rigid fixation devices on the loads in the lumbar spine : a finite element analysis. Eur Spine J 16 : 1223-1231, 2007 https://doi.org/10.1007/s00586-006-0292-8
- Schaeren S, Broger I, Jeanneret B : Minimum four-year follow-up of spinal stenosis with degenerative spondylolisthesis treated with decompression and dynamic stabilization. Spine (Phila Pa 1976) 33 : E636- E642, 2008 https://doi.org/10.1097/BRS.0b013e31817d2435
- Sengupta DK : Dynamic stabilization devices in the treatment of low back pain. Neurol India 53 : 466-474, 2005 https://doi.org/10.4103/0028-3886.22614
- Sengupta DK, Mulholland RC : Fulcrum assisted soft stabilization system : a new concept in the surgical treatment of degenerative low back pain. Spine (Phila Pa 1976) 30 : 1019-1029; discussion 1030, 2005 https://doi.org/10.1097/01.brs.0000160986.39171.4d
피인용 문헌
- Pedicle Screw-based Dynamic Stabilization with a Hinged Screw Head System in the Treatment of Lumbar Degenerative Disorders vol.8, pp.2, 2009, https://doi.org/10.14245/kjs.2011.8.2.102
- Effects of nonlinearity in the materials used for the semi-rigid pedicle screw systems on biomechanical behaviors of the lumbar spine after surgery vol.6, pp.5, 2009, https://doi.org/10.1088/1748-6041/6/5/055005
- Posterior Decompression and Fusion: Whole-Spine Functional and Clinical Outcomes vol.11, pp.8, 2009, https://doi.org/10.1371/journal.pone.0160213
- Biomechanical investigation of the effect of pedicle-based hybrid stabilization constructs: A finite element study vol.234, pp.9, 2020, https://doi.org/10.1177/0954411920934956