A Study on the Characteristics of Daylight Distributions by Different Sky Conditions and Controlled Roller Shade Heights

천공종류 및 롤러쉐이드의 제어된 높이에 따른 주광분포 특성에 관한 연구

  • 박병철 (세종대학교 건축공학과) ;
  • 임지선 (세종대학교 건축공학과) ;
  • 김유신 (세종대학교 건축공학과) ;
  • 이정호 (삼성건설 기술연구소) ;
  • 최안섭 (세종대학교 건축공학과)
  • Published : 2009.02.28

Abstract

Daylight responsive dimming systems are one of lighting control systems which are to control artificial lightings using available daylight for energy savings. This system is not popular because useful daylight is usually blocked by uncontrolled passive shading systems in buildings. It is necessary to integrate daylight responsive dimming systems and automata! roller shading systems. In this research, mock-up test is performed to analyze the daylight distributions in three different rooms for integrated systems. Roller shades are installed in two rooms. One is fully downed and the other is controlled by sun profile angle. The other room has no shading system as a reference room.

광센서 조광제어시스템은 주광을 이용하여 인공조명을 제어하는 대표적인 조명제어시스템이다. 그러나 실내에 설치된 고정된 쉐이딩시스템으로 인해 주광유입을 차단함으로써 광센서 조광제어시스템의 현장 적용성은 낮다. 광센서 조광제어시스템의 적용성 및 정확성의 향상을 위해 자동 롤러쉐이딩 시스템과의 통합은 필수적이다. 따라서 본 연구는 롤러쉐이드의 높이에 따른 주광유입분포의 특성을 분석하기 위하여 Mock-up(1/2스케일) 테스트를 시행하였다. Mock-up은 롤러쉐이드가 설치된 2개의 실과 쉐이딩시스템이 없는 1개의 실로 구성되었다. 롤러쉐이드가 설치된 2개의 실 중 1개소는 롤러쉐이드의 높이를 최하단으로 고정하였고, 다른 1개의 실은 태양의 일영각을 기준으로 직사일광의 실내유입깊이를 정하여 산출된 롤러쉐이드의 높이로 제어하였다.

Keywords

References

  1. IEA, IEA Energy Efficiency Policy Recommendations to the G8 2007 Summit, Heiligendamm, 2007
  2. Francis, A 외, European Energy Performance of Buildings Directive at EPIC 2006 AIVC Conference, 2007
  3. 김지연 외, 초고층건물의 조명에너지절약을 위한 BIPV적용에 관한연구, 한국태양에너지학회춘계학술발표대회논문집, 2007
  4. Choi, A 외, The Characteristics of Photosensors and Electronic Dimming Ballasts in Daylight Responsive Dimming Systems, Building and Environment, 40(1), 2005 https://doi.org/10.1016/j.buildenv.2004.07.014
  5. Peter R. Boyce, Human Factors in Lighting, 2nd Edition, Lighting Research Center, 2003
  6. NYSERDA, Daylighting the New York Times Headquarters Building, New York State Energy Research and Development Authority, 2005
  7. Park, B 외, Characteristics of Daylight Distributions in Different Shading Systems for Daylight Responsive Dimming System Performance, 7th InternationalConference on Sustainable Energy Technologies, 2008
  8. 임지선 외, Mock-up 실험을 통한 사무소 건축물의 Roller Shade 높이 제어 최적화에 관한 기초적 연구, 한국태양에너지학회 학술대회, 2008.4
  9. 이순지 외, 광센서 조광제어시스템의 성능향상을 위한 제어기울기 선정방법과 성능 평가에 관한 연구, 대한건축학회논문집, 22(11), 2006
  10. John A. Duffle et al., Solar Engineering of Thermal Processes, Third Edition, John Wiley & Sons, Inc., 2006

Cited by

  1. Proposal of the Prediction Equation for Interior Daylight Illuminance vol.33, pp.3, 2013, https://doi.org/10.7836/kses.2013.33.3.114