A Research on the $CO_2$ Peak Point Control According to Ventilation Rate During Sleeping

취침 시 환기횟수에 따른 $CO_2$ 피크치 제어에 관한 연구

  • Kim, Se-Hwan (Department of Building System Engineering, Dongeui University) ;
  • Kim, Dong-Gyu (Department of Mechnical Engineering, Pukyung National University) ;
  • Park, Jong-Il (Department of Building System Engineering, Dongeui University)
  • 김세환 (동의대학교 건축설비공학과) ;
  • 김동규 (부경대학교 기계공학부) ;
  • 박종일 (동의대학교 건축설비공학과)
  • Published : 2009.01.10

Abstract

Ventilation requirement of apartment was mandated according to building equipment standards in 2006. When ventilation unit was considering for indoor air quality maintenance, we needed energy saving and efficiency ventilation control methods. This study carried out experiment of ventilation rate 0.7 adequacy. When we lived in apartment, we assumed that sleeping time was long stayed time in unconsciousness. Experiments carried out ventilation rate 0, 0.1, 0.4 and 0.7 in environment chamber from 22 o'clock to 06 o'clock, the concentration of $CO_2$, temperature and humidity rate measured. Analyzing the results, conclusions are as follows. 1) When we sleep in bedroom, ventilation rate 0.4 meet the requirements of domestic legal standards. Conform fan of similarity law, ventilation rate 0.4 reduced power cost about 80% than 0.7. 2) In generally sleeping time 8 hours, peak point control reduced running time of ventilation unit about 43% than normal control.

Keywords

References

  1. Won, Y. M., Kim, D. S., Lee, W. J., Kim, D. G. and Kim, S. H., 2008, A research on the $CO_{2}$ Peak Point Control according to Ventilation Frequency during Sleeping, Proceedings of the SAREK 2008 Summer Annual Conference, p. 130
  2. Hyun, S. H. and Park, C. S., 2006 Indoor $CO_{2}$ concentration depending on diffuser location, ARCHITECTURAL INSTITUTE OF KOREA, Vol. 26, No. 1, pp. 653-656
  3. Min, B. S., 2005, A Study on the Field Survey and Improving Method of Indoor Air Quality in Apartment House, Ph.D, Kyonggi Unversity Graduate School, pp. 0-179
  4. Kim, D. G., Kim, S. Y. and Kim, S. H., 2007, A Study on the Assessment of the IAQ during Nightime, Korea Institute of Ecological Architecture and Environment, Vol. 7, No. 5, pp. 93-98
  5. Park S. H., Park J. W. and Hong C. H., 2002, A Study on Optimizing the Ventilation System in Apartment Building, ARCHITECTURAL INSTITUTE OF KOREA, Vol. 22, No. 2, pp. 693-696
  6. Choi, S. Y., Kim, S. H. and Lee, J. J., 2006, The Effect on Indoor Air Quality Improvement by Ventilation Rate in Newly Built Apartment, Korean journal of air-conditioning and refrigeration engineering, Vol. 18, No. 8, pp. 259-266
  7. Lee J. C., Kim D. W., Park B. H. and Kim B. S., 2006, The Reform Measure the Ventilation in Military Barracks by Computational Fluid Dynamics, ARCHITECTURAL INSTITUTE OF KOREA, Vol. 22, No. 12, pp. 275-283
  8. www.kma.go.kr