Abstract
Extra dosed bridge among the Cabled-stayed bridges have been increasingly built in korea in recently. But such bridges were often damaged by fire due to car collison. In this study Extra dosed bridges among the cabled-supported bridges are selected to analysis model frequently to be designed and/or constructed in recent and furture in this study. COSMOS FloWorks 2007 software are used for Heat Transfer Analysis and Thermal Stress Analysis. The safety of wire, HDPE pipe and stainless steel pipe are investigated. In the case of the constant of the temperature of the heat source, the significant three variables for the analysis are selected for study : (1) the distance between the fire-proof bulk head and the heat source, (2) wind velocity, (3) the height of the end of Stainless steel pipe.
최근 국내에서 케이블을 이용한 Extradosed 교 형식의 대교들이 건설되고 있다. 이러한 교량에서 자동차 충돌등으로 인한 화재에 의해 교량이 손상을 입는 사고가 발생되고 있어 화재에 대한 안정성해석이 필요하다. 본 연구에서는 케이블 교량형식 중 최근 국내에서 사용빈도가 높은 Extradosed 교 형식을 해석모델로 하였으며, 상용소프트웨어인 Solid Works 2007을 사용하여 모델링하고, COSMOS FloWorks 2007소프트웨어에 의한 열전달 해석 및 열응력 해석을 통하여 교량위 화재 발생시 와이어, 사재방재 파이프 및 그 주변에 대한 열유동 해석 및 사재방재 케이블의 안전을 검토하였다. 열원의 온도가 일정한 경우에 대해 다음 3개의 중요변수를 해석변수로 사용하였다. : (1)방호책과 열원사이의 거리, (2)풍속, (3) 스테인레스 강관의 끝단의 높이.