DOI QR코드

DOI QR Code

Seismic Performance of Post Tensioned Flat Plate Structures according to Slab Bottom Reinforcement

하부 철근 유무에 따른 포스트 텐션 플랫 플레이트 골조의 내진성능 평가

  • Published : 2008.08.31

Abstract

This study evaluates the seismic performance of post-tensioned flat plate structures with or without slab bottom reinforcement. For this purpose, 3 and 9 story frames were designed only considering gravity loads. This study conducts a nonlinear static pushover analysis. This study was an analytical model that is able to represent punching shear failure and fracture mechanism. The analytical results showed that the seismic performance of a post-tension flat plate is strongly influenced by the existence of slab bottom reinforcement through column. By placing slab bottom reinforcement in a PT flat plate frame, lateral strength and max drift capacity are significantly increased.

본 연구에서는 슬래브 하부철근이 포스트 텐션(PT) 플랫 플레이트 골조의 내진성능에 미치는 영향을 평가하였다. 이를 위하여 슬래브-기둥 접합부에 슬래브 하부철근이 있는 경우와 없는 경우의3층, 9층 골조를 중력하중만 고려하여 설계하였다. 본 연구에서는 대상 건물을 비선형 정적 푸쉬오버 해석하여 기둥을 관통하는 슬래브 하부철근 유무에 따른 전체 구조시스템 거동을 평가하였다. 본 연구에서 사용한 접합부 모델은 뚫림 전단과 파괴메커니즘을 예측할 수 있도록 본 연구자들에 의하여 기존 연구에서 제안된 것이다. 본 연구 결과에 따르면 슬래브 하부철근은 PT 플랫 플레이트 골조의 내진성능에 큰 영향을 미치는 것으로 나타났다. 특히 슬래브 하부 철근이 있는 PT 플랫 플레이트 골조는 슬래브 하부철근이 없는 골조에 비하여 최대 강도와 변형 능력이 크게 향상되었다.

Keywords

References

  1. Han, S.W., Kee, S.H., Kang, T.H.K., Ha, S.S., Ha, Wallace, J.W., Lee, L.H., "Cyclic Behaviour of Interior Post-tensioned Flat Plate Connections," Magazine of Concrete Research, Vol. 58, 2006, pp. 699-711 https://doi.org/10.1680/macr.2006.58.10.699
  2. Han, S.W., Kee, S.H., Park, Y.M., Lee, L.H., Kang, T.H.K., Hysteretic Behavior of Exterior Post-tensioned Flat Plate Connections," Engineering Structures, Elsevier, 2006, pp. 1983-1996
  3. Han, S.W., Kwon, O.S., Lee, L.H., "Evaluation of the Seismic Performance of a Three-story Ordinary Moment-Resisting Concrete Frame," Earthquake Engng Struct. Dyn. Vol. 33, 2004, pp. 669-685 https://doi.org/10.1002/eqe.367
  4. Han, S.W., Ryu, J.H., "Analytical Model for Post Tension Flat Plate Frames," The Journal of Earthquake Engineering Society of Korea, Vol. 11, No. 6, 2007, pp. 23-32 https://doi.org/10.5000/EESK.2007.11.6.023
  5. ACI Committee 318, Building Code Requirements for Reinforced Concrete (ACI 318-05), American Concrete Institute, Detroit, 2005
  6. MIDAS IT. MIDAS/GENw User's Manual(Version 6.3.2). Seoul, Korea, 2004
  7. Joint ACI-ASCE committee 352., Recommendation for Design of Slab-Column Connections in Monolithic Reinforced Concrete Structures(ACI 352.1R-89), Farmington Hills (MI): American Concrete Institute, 1997
  8. OpenSees Development Team (2006). OpenSees: Open System for Earthquake Engineering Simulations, Version 1.7.3, Berkeley, CA
  9. Banchik CA. Effective Beam Width Coefficients for Equivalent Frame Analysis of Flat-plate Structures, ME thesis, Univ. of California at Berkeley, CA., 1987
  10. Federal Emergency Management Agency, NEHRP Guidelines for the Seismic Rehabilitation of Buildings, FEMA 273, Washington, D.C., 1997