Abstract
This study was carried out to determinate the location and the number of air inlet and outlet, optimum air inlet velocity for effective ventilation in windowless weaning piglet house($2.90(W){\times}9.90(L){\times}2.80(H)$ m) by CFD(Computation Fluid Dynamics) simulation. The weaning piglet house for this experiment was consisted of 11 air inlets and 9 outlets, modified and simulated using CFD code, FLUENT. The simulation result for the original weaning piglet house, which was not modified, showed ununiform ventilation for each room. Therefore, for uniform ventilation, 4 air inlets and 1 outlet were completely closed, and 2 air outlets were partially closed. The simulation result for the modified weaning piglet house showed uniform ventilation for each room and the optimum air inlet velocity of 0.5 $m\;sec^{-1}$.
본 연구는 입기구가 11개이고 배기구가 9개인 무창이유자돈사에 대하여 CFD 시뮬레이션을 실시함으로써 겨울철 최적 환기를 위한 입 배기구의 위치와 개수 및 최적 공기 유입속도를 구명하고자 수행되었다. 배기팬에 가까운 돈방의 경우에는 나머지 돈방에 비해 상대적으로 음압이 크기 때문에 환기가 많이 되는 것으로 나타났고, 나머지 돈방의 경우에는 음압이 작아 환기가 적게 되는 것으로 나타났다. 이런 이유로 동일 면적의 입기구를 설치함에 있어서 같은 간격으로 배치하면 환기가 불균일하게 이루어지기 때문에, 배기팬에 가깝게 위치한 돈방에서는 입 배기구를 나머지 돈방에 비해 적게 만들어 주거나 간격을 넓게 만들어 줌으로써 균일한 환기를 할 수 있는 것으로 분석되었다. 특히 입기구가 11개이고 배기구가 9개인 무창돈사의 경우에는 동일 선상에 있는 입기구 4개를 폐쇄하며 배기구 1개는 완전 폐쇄하고 2개는 2/3를 폐쇄하였을 때 환기가 균일하게 되는 것으로 나타났다. 또한 실험돈사와 같이 돈사의 폭이 3 m 정도일 경우에는 입기구의 입공기 속도가 0.5 $m\;sec^{-1}$ 정도로 유지될 때 틈바닥 위 0.1 m 높이 위치의 풍속이 적정수준으로 유지되는 것으로 나타났다.