Abstract
The induced voltages by AT power feeding system of electrified traction line to telecommunication line are calculated with the method of multi-conductor line solution in the CCITT Directives. There is a screening effect by railway line itself among various shielding factors against induction. It is the argue point whether the multi-conductor line solution contains the railway line effect since the calculation method does not show any expression about shielding factors. So this paper illuminates the mysterious question by reviewing the shielding factor principle on traction system, scrutinizing the Japanese bible about induction, analyzing the multi-conductor line solution itself, and comparing the result calculation considering the effect of railway screen. This paper concludes that multi-conductor line solution contains the screening effect of railway lines.
전기철도인 고속전철시설에 의한 통신선 유도전압을 계산하는데 있어서는 CCITT Directives에 의한 다도체계산법을 사용한다. 통신시스템계에 미치는 전력시스템계에 의한 유도의 영향력에는 다양한 차폐 요소들이 존재하여 경감 요율로서 사용된다. 철도시스템계에 있어서는 철도의 선로(레일) 자체에 의한 궤도효과가 존재하는데 다도체계산법에 있어서 궤도효과가 반영된 결과인지에 대하여는 계산법 자체에 명시되어 있지 않으므로 유도전압 계산의 적정성에 대하여 논란이 되고 있다. 이러한 기술 문제의 해결을 위하여 본 논문에서는 궤도효과가 영향을 미칠 수 있는 원리적 범위를 고찰하고 궤도효과의 적용과 관련된 일본 유도자료 등의 사례를 통하여 그 의미를 해석한다. 그리고 다도체계산법 자체에서의 궤도효과 적용성을 분석하였다. 아울러 계산 시뮬레이션을 통한 유도전압을 비교하여 궤도효과의 적용성을 검증한다. 이상의 분석 결과를 종합하여 볼 때 다도체계산법상에는 궤도효과가 포함되어 있는 것으로 결론지을 수 있다.