Abstract

The research field of structural control has evolved from the development of passive devices since 1970s, through the intensive investigation on active systems in 1980s, to the recent studies of semi-active control systems in 1990s. Currently semi-active control is considered most promising in civil engineering applications. However, actual implementation of semi-active devices is still limited due mainly to their system maintenance and associated long-term reliability as a result of power requirement. In this paper, the concept of functionally upgraded passive devices is introduced to streamline some of the state-of-the-art researches and guide the development of new passive devices that can mimic the function of their corresponding semi-active control devices for various applications. The general characteristics of this special group of passive devices are discussed and representative examples are summarized. Their superior performances are illustrated with cyclic and shake table tests of two example devices: mass-variable tuned liquid damper and friction-pendulum bearing with a variable sliding surface curvature.

Keywords

References

  1. Batterbee, D. C. and Sims, N. D. (2005), "Vibration isolation with smart fluid dampers: a benchmarking study", Smart Struct. Sys., 1(3), 235-256. https://doi.org/10.12989/sss.2005.1.3.235
  2. Chen, G. D. and Wu, J. N. (2001), "Optimal placement of multiple tuned mass dampers for reducing seismic responses of buildings", ASCE J. Struct. Eng., 127(9), 1054-1062. https://doi.org/10.1061/(ASCE)0733-9445(2001)127:9(1054)
  3. Chen, G. D. and Wu, J. N. (2003), "Experimental study on multiple tuned mass dampers to reduce seismic responses of a three-story building structure", Earthq. Eng. Struct. Dyn., 32, 793-810. https://doi.org/10.1002/eqe.249
  4. Chen, G. D. and Chen, C. Q. (2004a), "Semi-active control of the 20-story benchmark building with piezoelectric friction dampers", ASCE J. Eng, Mech., 130(4), 393-400. https://doi.org/10.1061/(ASCE)0733-9399(2004)130:4(393)
  5. Chen, C. Q. and Chen, G. D. (2004b), "Shake table tests of a -scale three-story building model with piezoelectric friction dampers", Struct. Control Health Monitoring, 11(4), 239-257. https://doi.org/10.1002/stc.41
  6. Hall, J. F., Heaton, T. H., Halling, M. W. and Wald, D. J. (1995), "Near-source ground motions and its effects on flexible buildings", Earthq. Spectra, 11, 569-605. https://doi.org/10.1193/1.1585828
  7. Jangid, R. S. and Kelly, J. M. (2001), "Base isolation for near-fault motion", Earthq. Eng. Struct. Dyn., 30, 691-707. https://doi.org/10.1002/eqe.31
  8. Jung, H. J., Choi, K. M., Park, K. S. and Cho, S. W. (2007), "Seismic protection of base isolated structures using smart passive control system", Smart Struct. Sys., 3(3), 385-403. https://doi.org/10.12989/sss.2007.3.3.385
  9. Lu, L. Y., Shih, M. H., Chang Chien, C. S. and Chang, W. N. (2002), "Seismic performance of sliding isolated structures in near-fault areas", Proc. 7th US National Conference on Earthquake Engineering, Session AT-2, July 21-25, Boston, MA, USA.
  10. Lu, L. Y., Shih, M. H., Tzeng, S. W. and Chang Chien, C. S. (2003), "Experiment of a sliding isolated structure subjected to near-fault ground motion", Proc. 7th Pacific Conference on Earthquake Engineering, February 13-15, Christchurch, New Zealand.
  11. Lu, L. Y., Wang, J. and Hsu, C. C. (2006), "Experiment and analysis of sliding bearings with variable frequency for near-fault seismic isolation", Proc. 1st European Conf. on Earthq. Eng. Seis., Geneva, Switzerland, Sept. 3-8, Paper No. 183.
  12. Ma, K. and Ghasemi-Nejhad, M. N. (2005), "Simultaneous precision positioning and vibration suppression of reciprocating flexible manipulators", Smart Struct. Sys., 1(1), 13-27. https://doi.org/10.12989/sss.2005.1.1.013
  13. Maiti, D. K., Shyju, P. P. and Vijayaraju, K. (2006), "Vibration control of mechanical systems using semi-active MR-damper", Smart Struct. Sys., 2(1), 61-80. https://doi.org/10.12989/sss.2006.2.1.061
  14. Makris, N. and Chang, S. P. (2000), "Effect of viscous, viscoplastic and friction damping on the response of seismic isolated structures", Earthq. Eng. Struct. Dyn., 29, 85-107. https://doi.org/10.1002/(SICI)1096-9845(200001)29:1<85::AID-EQE902>3.0.CO;2-N
  15. Manjunath, T. C. and Bandyopadhyay, B. (2005), "Modeling and fast output sampling feedback control of a smart Timoshenko cantilever beam", Smart Struct. Sys., 1(3), 283-308. https://doi.org/10.12989/sss.2005.1.3.283
  16. Mokha, A., Constantinous, M. C., Reinhorn, A. M. and Zayas, V. A. (1991), "Experimental study of frictionpendulum isolation system", ASCE J. Struct. Eng., 117(4), 1201-1217. https://doi.org/10.1061/(ASCE)0733-9445(1991)117:4(1201)
  17. Naeim, F. and Kelly, J. M. (1999), Design of Seismic Isolated Structures: From Theory to Practice, John Wiley & Sons.
  18. Reed, D., Yu, J., Yeh, H. and Gardarsson, S. (1998), "Investigation of tuned liquid dampers under large amplitude excitation", ASCE J. Eng. Mech., 124(4), 405-413. https://doi.org/10.1061/(ASCE)0733-9399(1998)124:4(405)
  19. Samali, B., Wildjaja, J. and Rezes, J. (2006), "The controllable fluid dashpot damper performance", Smart Struct. Sys., 2(3), 209-224. https://doi.org/10.12989/sss.2006.2.3.209
  20. Soong, T. T. (1990), Active Structural Control: Theory and Application, John Wiley & Son, New York, NY.
  21. Soong, T. T. and Dargush, G. (1997), Passive Energy Dissipation Systems in Structural Engineering, John Wiley & Son, NY.
  22. Sun, L. M. (1991), "Semi-analytical modeling of tuned liquid damper (TLD) with emphasis on damping of liquid sloshing", Ph.D. Dissertation, University of Tokyo, Tokyo, Japan.
  23. Syrmakezis, C. A., Mavrouli, O. A. and Antonopoulos, A. K. (2006), "Rehabilitation of hospital buildings using passive control systems", Smart Struct. Sys., 2(4), 305-312. https://doi.org/10.12989/sss.2006.2.4.305
  24. Vakakis, A. F., McFarland, D. M. and Bergman, L. A. (2003), "Vibration suppression by energy pumping", Proc. US-Europe Workshop on Sensors and Smart Structures Technology, Como and Somma Lombardo, Italy, 73-82.
  25. Warnitchai, P. and Hoang, N. (2006), "Optimal placement and tuning of multiple tuned mass dampers for suppressing multi-mode structural response", Smart Struct. Sys., 2(1), 1-24. https://doi.org/10.12989/sss.2006.2.1.001
  26. Xin, Y. X. (2006), "Seismic performance of mass-variable tuned liquid dampers with particles fluidization in building applications", Ph.D. Dissertation, University of Missouri-Rolla, Rolla, USA.
  27. Zhang, Y. F. and Zhu, S. (2006), "Seismic behavior of framed structure with self-centering damping braces", Proc. 4th World Conf. on Struct. Control and Monitoring, Paper No. 136, San Diego, CA.

Cited by

  1. Seismic response control with density-variable tuned liquid dampers vol.8, pp.4, 2009, https://doi.org/10.1007/s11803-009-9111-7
  2. Experimental study of variable-frequency rocking bearings for near-fault seismic isolation vol.46, 2013, https://doi.org/10.1016/j.engstruct.2012.07.013
  3. Experiment of an ABS-type control strategy for semi-active friction isolation systems vol.8, pp.5, 2008, https://doi.org/10.12989/sss.2011.8.5.501
  4. Flow Damping Devices in Tuned Liquid Damper for Structural Vibration Control: A Review vol.28, pp.4, 2008, https://doi.org/10.1007/s11831-020-09450-0
  5. An equivalent mechanical model with nonlinear damping for sloshing rectangular tank with porous media vol.242, pp.None, 2008, https://doi.org/10.1016/j.oceaneng.2021.110145