참고문헌
- Ayres, J. W., Lalande, F., Chandhvy, Z. and Rogers L. A. (1998), "Qualitative impedance-based health monitorind of civil infrastructures", Smart Mater. Struct., 7, 599-605. https://doi.org/10.1088/0964-1726/7/5/004
- Baz, A. (1997), "Boundary control of beams using active constrained layer damping", J. Vib. Acoustics, 119, 116-172.
- Bhalla, S., Soh, C. K. and Liu, Z. (2005), "Wave propagation approach for NDE using surface bonded piezoceramics", NDT & E Intrn., 38, 143-150. https://doi.org/10.1016/j.ndteint.2004.07.009
- Hau, L. C. and Fung, E. H. K. (2004), "Effect of ACLD treatment confifuration on damping performance of a flexible beam", J. Sound Vib., 269, 549-567. https://doi.org/10.1016/S0022-460X(03)00041-5
- Kim, J., Varadan, V. V. and Varadan, V. K. (1996), "Finite element modeling of a smart cantilever plate and comparison with experiments", Smart Mater. Struct., 5, 165-170. https://doi.org/10.1088/0964-1726/5/2/005
- Lim, Y. H., Varadan, V. V. and Varadan, V. K. (1999), "Closed loop finite element modeling of active structural damping in the time domain", Smart Mater. Struct., 8, 390-400, 1999. https://doi.org/10.1088/0964-1726/8/3/310
- Littlefield, A., Fair-Weather, J. and Craig, K. (2002), "Use of FEA derived impedances to design active structures", J. Intelligent Material System and Structures, 13, 377-388. https://doi.org/10.1177/104538902761696724
- Liu, T., Hua, H. and Z. Zhang, Z. (2004), "Robust control of plate vibration via active constrained layer damping", Thin-Walled Structures, 42, 427-448. https://doi.org/10.1016/S0263-8231(03)00131-9
- MSC. MARC 2005, Users Guide, MSC. Software, CA, USA, 2005
- Rao, S. S. and Sunar, M. (1993), "Analysis of distributed thermopiezoelectric sensors and actuators in advanced intelligent structures", AIAA J., 131, 1280-1286.
- Shen, I. Y. (1994), "Hybrid damping through intelligent constrained layer damping treatments", ASME J. Vib. Acoust., 116, 341-349. https://doi.org/10.1115/1.2930434
- Soh, C. K., Tseng, K. K. H., Bhalla, S. and Gupta, A. (2000), "Performance of smart piezoceramic patches in helth monitoring of a RC Bridge", Smart Mater. Struct., 9, 533-542. https://doi.org/10.1088/0964-1726/9/4/317
- Sun, F. P., Chaudhvy, Z. Rogers, C. A., Majmn, M. and Liang, C. (1995), "Automatel real-time structure health monitoring via signature pattern recognition", Proceedings of SPIE conference on Smart Structures and Materials, San Diego, CA. 7, 559-605.
- Tseng, K. K. and Wang, L. (2005), "Structural damage identification for thin plates using smart piezoelectric transducers", Comp. Meth. Appl. Mech. Eng., 194, 3192-3209. https://doi.org/10.1016/j.cma.2004.08.007
- Tzou, H. S. and Tseng, C. I. (1990), "Distributed piezoelectric sensor/actuator design for dynamic measurement control of distributed parameter systems : a piezoelectric finite element approach", J Sound Vib., 138, 17-34. https://doi.org/10.1016/0022-460X(90)90701-Z
- Van Nostran, W. C., Knowles, G. and Iuman, D. (1994), "Finite element model for active constrained damping", Proc. Conf. Smart Struct. Mater. SPIE, 2173, 269-281.
- Varadan, V. V., Lim, Y. and Varadan, V. K. (1996), "Closed loop finite element modeling of active/passive damping in structural vibration control", Smart Mater. Struct., 5, 685-694. https://doi.org/10.1088/0964-1726/5/5/016
- Wang, Q., Duan, W. H. and Quek, S. T. (2004), "Repair of notched beam under dynamic load using piezoelectric patch", Int. J. Mech. Sci., 46, 1517-1533. https://doi.org/10.1016/j.ijmecsci.2004.09.012
피인용 문헌
- Health Monitoring of Nuclear Structure Containment Using Strain Gauges to Assess the Integrity vol.2013, 2013, https://doi.org/10.1155/2013/149458
- Detection of flexural damage stages for RC beams using Piezoelectric sensors (PZT) vol.15, pp.4, 2015, https://doi.org/10.12989/sss.2015.15.4.997
- Repair of Cracked Structures under Dynamic Load Using Electromechanical Admittance Approach vol.348-349, pp.1662-9795, 2007, https://doi.org/10.4028/www.scientific.net/KEM.348-349.49