DOI QR코드

DOI QR Code

Effect of building volume and opening size on fluctuating internal pressures

  • Ginger, John D. (Cyclone Testing Station, James Cook University) ;
  • Holmes, John D. (JDH Consulting) ;
  • Kopp, Gregory A. (Boundary Layer Wind Tunnel Laboratory, University of Western Ontario)
  • 투고 : 2008.02.27
  • 심사 : 2008.07.30
  • 발행 : 2008.10.25

초록

This paper considers internal pressure fluctuations for a range of building volumes and dominant wall opening areas. The study recognizes that the air flow in and out of the dominant opening in the envelope generates Helmholtz resonance, which can amplify the internal pressure fluctuations compared to the external pressure, at the opening. Numerical methods were used to estimate fluctuating standard deviation and peak (i.e. design) internal pressures from full-scale measured external pressures. The ratios of standard deviation and peak internal pressures to the external pressures at a dominant windward wall opening of area, AW are presented in terms of the non-dimensional opening size to volume parameter, $S^*=(a_s/\bar{U}_h)^2(A_W^{3/2}/V_{Ie})$ where $a_s$ is the speed of sound, $\bar{U}_h$ is the mean wind speed at the top of the building and $V_{Ie}$ is the effective internal volume. The standard deviation of internal pressure exceeds the external pressures at the opening, for $S^*$ greater than about 0.75, showing increasing amplification with increasing $S^*$. The peak internal pressure can be expected to exceed the peak external pressure at the opening by 10% to 50%, for $S^*$ greater than about 5. A dominant leeward wall opening also produces similar fluctuating internal pressure characteristics.

키워드

참고문헌

  1. American Society of Civil Engineers (2005), Minimum design loads for buildings and other structures, ASCE 7-05, A.S.C.E., New York.
  2. Ginger, J.D., Yeatts, B.B. and Mehta, K.C. (1995), "Internal pressures in a low-rise full-scale building", Proc. 9th International Conference in Wind Engineering, New Delhi, Vol 1 (1995) 512-523.
  3. Ginger, J.D., Mehta, K.C. and Yeatts, B.B.(1997), "Internal pressures in a low-rise full scale building", J. Wind Eng. Ind. Aerodyn., 72, 163-174. https://doi.org/10.1016/S0167-6105(97)00241-9
  4. Ginger, J.D. (2000), "Internal pressure and cladding net wind loads on full scale low-rise building", ASCE Struct Eng, 126, 538-543. https://doi.org/10.1061/(ASCE)0733-9445(2000)126:4(538)
  5. Harris, R.I. (1990), "The propagation of internal pressures in buildings", J. Wind Eng. Ind. Aerodyn., 34, 169-184. https://doi.org/10.1016/0167-6105(90)90142-Y
  6. Holmes, J.D. (1979), "Mean and fluctuating internal pressures induced by wind", Proc. 5th Int. Conf. on Wind Eng., Colorado USA, Vol. 1, pp. 435-450, Permagamon Press, Oxford, U.K.
  7. Holmes, J.D. (2008), Discussion of : "Net pressures on the roof of a low-rise building with wall openings" by Sharma,R.N. and Richards, P.J., J. Wind Eng Ind. Aerodyn. 93, 267-291, 2005, to appear 2008. https://doi.org/10.1016/j.jweia.2005.01.001
  8. Kopp, G.A., Oh, J.H. and Inculet, D.R. (2008), "Wind induced internal pressure in houses", ASCE J. Struct Eng, 134, 1129-1138. https://doi.org/10.1061/(ASCE)0733-9445(2008)134:7(1129)
  9. Levitan, M.L. and Mehta, K.C. (1992), "Texas Tech field experiments for wind loads. Part II: Meteorological instrumentation and terrain parameters", J. Wind Eng. Ind. Aerodyn., 43, 1577-1588. https://doi.org/10.1016/0167-6105(92)90373-I
  10. Liu, H. (1978), "Building code requirements on internal pressure", 3rd US Conference on Wind Engineering, Gainesville, Florida, USA, VI-7.
  11. Oh, J.H., Kopp, G.A.,Inculet, D.R. (2007), "The UWO contribution to the NIST aerodynamic database for wind loads on low buildings: Part 3. Internal pressures", J. Wind Eng. Ind. Aerodyn., 95, 755-779. https://doi.org/10.1016/j.jweia.2007.01.007
  12. Sharma, R.N. and P. J. Richards, P.J. (2003), "The influence of Helmholtz resonance on internal pressures in a low-rise building", J. Wind Eng. Ind. Aerodyn., 91, 807-828 https://doi.org/10.1016/S0167-6105(03)00005-9
  13. Shi-ce, Yu Wen-juan, Lou and Bing-nan, Sun (2006), "Wind-induced internal pressure fluctuations of structure with single windward opening", J. Zhejiang University, Science A,7 (3), 415-423 https://doi.org/10.1631/jzus.2006.A0415
  14. Standards Australia, (2002),. Structural design actions. Part 2: Wind actions. Australian/New Zealand Standard AS/NZS 1170.2:2002.
  15. Vickery, B.J. (1994), "Internal pressures and interactions with the building envelope", J. Wind Eng. Ind. Aerodyn., 53 125-144 https://doi.org/10.1016/0167-6105(94)90022-1

피인용 문헌

  1. Measurements of the performance of a wind-driven ventilation terminal vol.163, pp.2, 2010, https://doi.org/10.1680/stbu.2010.163.2.129
  2. Internal pressure dynamics of a leaky building with a dominant opening vol.99, pp.11, 2011, https://doi.org/10.1016/j.jweia.2011.09.002
  3. Variation of Internal Pressure with Varying Sizes of Dominant Openings and Volumes vol.136, pp.10, 2010, https://doi.org/10.1061/(ASCE)ST.1943-541X.0000225
  4. Finite element analysis of interaction of tornados with a low-rise timber building vol.99, pp.4, 2011, https://doi.org/10.1016/j.jweia.2011.01.004
  5. Wind-Induced Internal Pressures in Buildings with Large Façade Openings vol.138, pp.4, 2012, https://doi.org/10.1061/(ASCE)EM.1943-7889.0000296
  6. Internal Pressure in Real Flexible Porous Buildings with a Dominant Opening: Design Perspective vol.139, pp.2, 2013, https://doi.org/10.1061/(ASCE)ST.1943-541X.0000645
  7. Assessment of damage to residential construction from the tornadoes in Vaughan, Ontario, on 20 August 2009 vol.41, pp.6, 2014, https://doi.org/10.1139/cjce-2013-0570
  8. Internal pressures – The dominant windward opening case – A review vol.100, pp.1, 2012, https://doi.org/10.1016/j.jweia.2011.11.005
  9. Wind-driven natural ventilation in a low-rise building: A Boundary Layer Wind Tunnel study vol.59, 2013, https://doi.org/10.1016/j.buildenv.2012.08.026
  10. Response of pierced fixed corrugated steel roofing systems subjected to wind loads vol.33, pp.12, 2011, https://doi.org/10.1016/j.engstruct.2011.08.020
  11. Simulated tropical cyclonic winds for low cycle fatigue loading of steel roofing vol.12, pp.4, 2008, https://doi.org/10.12989/was.2009.12.4.383
  12. Scaling methods for wind tunnel modelling of building internal pressures induced through openings vol.13, pp.4, 2008, https://doi.org/10.12989/was.2010.13.4.363
  13. Wind induced internal pressure overshoot in buildings with opening vol.16, pp.1, 2013, https://doi.org/10.12989/was.2013.16.1.001
  14. Internal pressures in buildings with a dominant opening and background porosity vol.16, pp.1, 2008, https://doi.org/10.12989/was.2013.16.1.047
  15. Internal pressure dynamics of a leaky and quasi-statically flexible building with a dominant opening vol.16, pp.1, 2008, https://doi.org/10.12989/was.2013.16.1.061
  16. Internal and net roof pressures for a dynamically flexible building with a dominant wall opening vol.16, pp.1, 2008, https://doi.org/10.12989/was.2013.16.1.093
  17. Field studies of wind induced internal pressure in a warehouse with a dominant opening vol.16, pp.1, 2008, https://doi.org/10.12989/was.2013.16.1.117
  18. The loss coefficient for fluctuating flow through a dominant opening in a building vol.24, pp.1, 2008, https://doi.org/10.12989/was.2017.24.1.079
  19. Variation in wind load and flow of a low-rise building during progressive damage scenario vol.28, pp.6, 2008, https://doi.org/10.12989/was.2019.28.6.389
  20. Steady-state and transient wind characteristics of low-rise building roofs with openings in vulnerable areas vol.23, pp.11, 2008, https://doi.org/10.1177/1369433220911116
  21. Wind tunnel study on fluctuating internal pressure of open building induced by tangential flow vol.32, pp.2, 2008, https://doi.org/10.12989/was.2021.32.2.105