DOI QR코드

DOI QR Code

Bound of aspect ratio of base-isolated buildings considering nonlinear tensile behavior of rubber bearing

  • Hino, J. (Department of Urban & Environmental Engineering, Graduate School of Engineering, Kyoto University) ;
  • Yoshitomi, S. (Department of Urban & Environmental Engineering, Graduate School of Engineering, Kyoto University) ;
  • Tsuji, M. (Department of Urban & Environmental Engineering, Graduate School of Engineering, Kyoto University) ;
  • Takewaki, I. (Department of Urban & Environmental Engineering, Graduate School of Engineering, Kyoto University)
  • 투고 : 2008.01.21
  • 심사 : 2008.07.31
  • 발행 : 2008.10.20

초록

The purpose of this paper is to propose a simple analysis method of axial deformation of base-isolation rubber bearings in a building subjected to earthquake loading and present its applicability to the analysis of the bound of the aspect ratio of base-isolated buildings. The base shear coefficient is introduced as a key parameter for the bound analysis. The bound of the aspect ratio of base-isolated buildings is analyzed based on the relationship of the following four quantities; (i) ultimate state of the tensile stress of rubber bearings based on a proposed simple recursive analysis for seismic loading, (ii) ultimate state of drift of the base-isolation story for seismic loading, (iii) ultimate state of the axial compressive stress of rubber bearings under dead loads, (iv) prediction of the overturning moment at the base for seismic loading. In particular, a new recursive analysis method of axial deformation of rubber bearings is presented taking into account the nonlinear tensile behavior of rubber bearings and it is shown that the relaxation of the constraint on the ultimate state of the tensile stress of rubber bearings increases the limiting aspect ratio.

키워드

참고문헌

  1. Ariga, T., Kanno, Y. and Takewaki, I. (2006), "Resonant behavior of base-isolated high-rise buildings under long-period ground motions", Struct. Des. Tall Spec., 15(3), 325-338 https://doi.org/10.1002/tal.298
  2. Hall, J.H., Heaton, T.H., Halling, M.W. and Wald, D.J. (1995), "Near-source ground motion and its effect on flexible buildings", Earthq. Spectra, 11, 569-605 https://doi.org/10.1193/1.1585828
  3. Heaton, T.H., Hall, J.H., Wald, D.J. and Halling, M.W. (1995), "Response of high-rise and base-isolated buildings in a hypothetical MW 7.0 blind thrust earthquake", Sci., 267, 206-211 https://doi.org/10.1126/science.267.5195.206
  4. Irikura, K., Kamae, K. and Kawabe, H. (2004), "Importance of prediction of long-period ground motion during large earthquakes", In Annual Conference of the Seismological Society of Japan, Poster session (in Japanese)
  5. Jangid, R.S. (1995), "Optimum isolator damping for minimum acceleration response of base-isolated structures", Australian Civil Eng. Transactions, 37, 325-331
  6. Jangid, R.S. and Banerji, P. (1998), "Effects of isolation damping on stochastic response of structures with nonlinear base isolators", Earthq. Spectra., 14, 95-114 https://doi.org/10.1193/1.1585990
  7. Jangid, R.S. and Datta, T.K. (1994), "Non-linear response of torsionally coupled base isolated structure", J. Struct. Eng., ASCE, 120, 1-22 https://doi.org/10.1061/(ASCE)0733-9445(1994)120:1(1)
  8. Jangid, R.S. and Kelly, J.M. (2001), "Base isolation for near-fault motions", Earthq. Eng. Struct. Dyn., 30, 691- 707 https://doi.org/10.1002/eqe.31
  9. Jennings, P.C. (1968), "Equivalent viscous damping for yielding structures", J. Eng. Mech. Div., ASCE, 94(EM1), 103-116
  10. Kamae, K., Kawabe, H. and Irikura, K. (2004), "Strong ground motion prediction for huge subduction earthquakes using a characterized source model and several simulation techniques", In Proceedings of the13th WCEE, Vancouver
  11. Kelly, J.M. (1999), "The role of damping in seismic isolation", Earthq. Eng. Struct. Dyn., 28, 3-20 https://doi.org/10.1002/(SICI)1096-9845(199901)28:1<3::AID-EQE801>3.0.CO;2-D
  12. Kobori, T. (2004), Seismic-Response-Controlled Structure (New edition). Kajima Publisher: Tokyo (in Japanese)
  13. Li, H.-N. and Wu, X.-X. (2006), "Limitations of height-to-width ratio for base-isolated buildings under earthquake", Struct. Des. Tall Spec., 15, 277-287 https://doi.org/10.1002/tal.295
  14. Morales, C.A. (2003), "Transmissibility concept to control base motion in isolated structures", Eng. Struct., 25(10), 1325-1331 https://doi.org/10.1016/S0141-0296(03)00084-1
  15. Naeim, F. and Kelly, J.M. (1999), Design of Seismic Isolated Structures. Wiley, New York
  16. Nakamura, T. and Yamane, T. (1986), "Optimum design and earthquake-response constrained design for elastic shear buildings", Earthq. Eng. Struct. Dyn., 14, 797-815 https://doi.org/10.1002/eqe.4290140508
  17. Newmark, N.M. and Hall, W.J. (1982), Earthquake Spectra and Design. Earthquake Engineering Research Institute, Berkeley, CA
  18. Takewaki, I. (2004), "Frequency domain modal analysis of earthquake input energy to highly damped passive control structures", Earthq. Eng. Struct. Dyn., 33(5), 575-590 https://doi.org/10.1002/eqe.361
  19. Takewaki, I. (2005), "Uncertain-parameter sensitivity of earthquake input energy to base-isolated structure", Struct. Eng. Mech., 20(3), 347-362 https://doi.org/10.12989/sem.2005.20.3.347
  20. Takewaki, I. (2008), "Robustness of base-isolated high-rise buildings under code-specified ground motions", Struct. Des. Tall Spec., 17(2), 257-271 https://doi.org/10.1002/tal.350
  21. Thomson, W.T., Calkins, C. and Caravani, P. (1974), "A numerical study of damping", Earthq. Eng. Struct. Dyn., 3, 97-103 https://doi.org/10.1002/eqe.4290030108

피인용 문헌

  1. Innovative Seismic Response-Controlled System with Shear Wall and Concentrated Dampers in Lower Stories vol.3, 2017, https://doi.org/10.3389/fbuil.2017.00057
  2. A mechanical tension-resistant device for lead rubber bearings vol.152, 2017, https://doi.org/10.1016/j.engstruct.2017.09.006
  3. Demand response modification factor for the investigation of inelastic response of base isolated structures vol.5, pp.1, 2013, https://doi.org/10.12989/eas.2013.5.1.023
  4. New experimental system for base-isolated structures with various dampers and limit aspect ratio vol.5, pp.4, 2013, https://doi.org/10.12989/eas.2013.5.4.461
  5. Hybrid Control System for Greater Resilience Using Multiple Isolation and Building Connection vol.2, 2016, https://doi.org/10.3389/fbuil.2016.00026
  6. Instantaneous earthquake input energy and sensitivity in base-isolated building vol.20, pp.6, 2011, https://doi.org/10.1002/tal.539
  7. Numerical investigation on multi-degree-freedom nonlinear chaotic vibration isolation vol.51, pp.4, 2014, https://doi.org/10.12989/sem.2014.51.4.643
  8. Dual Control High-rise Building for Robuster Earthquake Performance vol.3, 2017, https://doi.org/10.3389/fbuil.2017.00012
  9. Smart passive control of buildings with higher redundancy and robustness using base-isolation and inter-connection vol.4, pp.6, 2013, https://doi.org/10.12989/eas.2013.4.6.649
  10. Seismic Response of Base-Isolated High-Rise Buildings under Fully Nonstationary Excitation vol.2014, 2014, https://doi.org/10.1155/2014/401469
  11. Automatic generation of smart earthquake-resistant building system: Hybrid system of base-isolation and building-connection vol.2, pp.2, 2016, https://doi.org/10.1016/j.heliyon.2016.e00069
  12. Theoretical tensile model and cracking performance analysis of laminated rubber bearings under tensile loading vol.52, pp.1, 2014, https://doi.org/10.12989/sem.2014.52.1.075
  13. Simulation of the response of base-isolated buildings under earthquake excitations considering soil flexibility vol.11, pp.3, 2012, https://doi.org/10.1007/s11803-012-0127-z
  14. Modeling and analysis of laminated rubber bearings under axial tensile loading vol.47, pp.6, 2014, https://doi.org/10.1617/s11527-013-0108-3
  15. A Simple Response Evaluation Method for Base-Isolation Building-Connection Hybrid Structural System under Long-Period and Long-Duration Ground Motion vol.4, 2018, https://doi.org/10.3389/fbuil.2018.00002
  16. Effects of Vertical Stiffness of Rubber Bearings on the Vertical Seismic Response of Isolated High-rise Building vol.218, pp.1755-1315, 2019, https://doi.org/10.1088/1755-1315/218/1/012001
  17. Minimum deformability design of high-strength concrete beams in non-seismic regions vol.8, pp.4, 2008, https://doi.org/10.12989/cac.2011.8.4.445
  18. Performance of multi-storey structures with high damping rubber bearing base isolation systems vol.39, pp.3, 2008, https://doi.org/10.12989/sem.2011.39.3.399
  19. Inelastic design of high-axially loaded concrete columns in moderate seismicity regions vol.39, pp.4, 2008, https://doi.org/10.12989/sem.2011.39.4.559
  20. Concurrent flexural strength and deformability design of high-performance concrete beams vol.40, pp.4, 2008, https://doi.org/10.12989/sem.2011.40.4.541
  21. Seismic analysis and modeling of isolated elevated liquid storage tanks vol.2, pp.4, 2008, https://doi.org/10.12989/eas.2011.2.4.397
  22. Design optimization of triple friction pendulums for base-isolated high-rise buildings vol.22, pp.13, 2008, https://doi.org/10.1177/1369433219849840
  23. A Simple Critical Response Evaluation Method for Base-Isolation Building-Connection Hybrid System Under Double Impulse as Representative of Near-Fault Ground Motion vol.7, pp.None, 2008, https://doi.org/10.3389/fbuil.2021.790584