Passive, semi-active, and active tuned-liquid-column dampers

  • Chen, Yung-Hsiang (Department of Civil Engineering, National Taiwan University) ;
  • Ding, Ying-Jan (Construction and Planning Agency, Ministry of the Interior)
  • 투고 : 2007.04.06
  • 심사 : 2008.06.03
  • 발행 : 2008.09.10

초록

The dynamic characteristics of the passive, semi-active, and active tuned-liquidcolumn dampers (or TLCDs) are studied in this paper. The design of the latter two are based on the first one. A water-head difference (or simply named as water head in this paper) of a passive TLCD is pre-set to form the so-called semi-active one in this paper. The pre-set of water head is released at a proper time instant during an earthquake excitation in order to enhance the vibration reduction of a structure. Two propellers are installed along a shaft inside and at the center of a passive TLCD to form an active one. These two propellers are driven by a servo-motor controlled by a computer to provide the control force. The seismic responses of a five-story shear building with a passive, semiactive, and active TLCDs are computed for demonstration and discussion. The responses of this building with a tuned mass damper (or TMD) are also included for comparison. The small-scale shaking-table experiments of a pendulum-like system with a passive or active TLCD to harmonic and seismic excitations are conducted for verification.

키워드

참고문헌

  1. Balendra, T., Wang, C.M. and Cheong, H.F. (1995), "Effectiveness of tuned liquid column dampers for vibration control of towers", Eng. Struct., 17(9), 668-675 https://doi.org/10.1016/0141-0296(95)00036-7
  2. Chen, Y.H. and Chao, C.C. (2000), "Optimal damping ratios of TLCDs", Struct. Eng. Mech., 9(3), 227-240 https://doi.org/10.12989/sem.2000.9.3.227
  3. Chen, Y.H. and Ko, C.H. (2003), "Active tuned liquid column damper with propellers", Earthq. Eng. Struct. Dyn., 32, 1627-1638 https://doi.org/10.1002/eqe.295
  4. Clough, R.W. and Renzien, J. (1993), Dynamics of Structures, McGraw-Hill, 2nd Edition, New York
  5. Den Hartog, J.P. (1962), Mechanical Vibrations, McGraw-Hill, 4th Edition, 93-106
  6. Gao, H., Kwok, K.S.C. and Samali, B. (1999), "Characteristics of multiple tuned liquid column dampers in suppressing structural vibration", Eng. Struct., 21, 316-331 https://doi.org/10.1016/S0141-0296(97)00183-1
  7. Hitchcock, P.A., Kwok, K.C.S., Watkins, R.D. and Samali, B. (1997), "Characteristics of Liquid Column Vibration Absorbers (LCVA)-I, II", Eng. Struct., 19, 126-144 https://doi.org/10.1016/S0141-0296(96)00042-9
  8. Jacquot, R.G. and Hoppe, D. (1973), "Optimal random vibration absorber", J. Eng. Mech. Div., ASCE, 99, 612-616
  9. Lewis, E.V. (1989), Principles of Naval Architecture, 2nd Edition, Vol. III, Chapter VIII, 126-133
  10. Sakai, F., Takeda, S. and Tamaki, T. (1989), "Tuned liquid column damper-new type device for suppression of building vibrations", Proc. of International Conf. on Highrise Building, 926-931, Nanjing, China
  11. Sun, K. (1994), "Earthquake responses of buildings with liquid column dampers", Proc. of the Fifth U.S. National Conf. on Earthquake Engineering, (Chicago, U.S.A.), 2, 411-420
  12. Won, A.Y.J., Piers, J.A. and Haroun, M.A. (1996), "Stochastic seismic performance evaluation of tuned liquid column dampers", Earthq. Eng. Struct. Dyn., 25, 1259-1274 https://doi.org/10.1002/(SICI)1096-9845(199611)25:11<1259::AID-EQE612>3.0.CO;2-W
  13. Xue, S.D., Ko, J.M. and Xu, Y.L. (2000), "Tuned liquid column damper for suppressing pitching motion of structure", Eng. Struct., 23, 1538-1551
  14. Yalla, Swaroop K. and Kareem, Ahsan. (2000), "Optimum absorber parameters for tuned liquid column dampers", J. Struct. Eng., ASCE, 126(8), 906-915 https://doi.org/10.1061/(ASCE)0733-9445(2000)126:8(906)

피인용 문헌

  1. Experimental Study on Variation Rules of Damping with Influential Factors of Tuned Liquid Column Damper vol.2017, 2017, https://doi.org/10.1155/2017/6209205
  2. Nonlinear Dynamic Characteristics of Rectangular and Cylindrical TLDs vol.144, pp.9, 2018, https://doi.org/10.1061/(ASCE)EM.1943-7889.0001510
  3. An adaptive tuned mass damper based on the emulation of positive and negative stiffness with an MR damper vol.20, pp.1, 2008, https://doi.org/10.1088/0964-1726/20/1/015012