초록
A typical louvered-fin oil cooler can be easily contaminated under dusty environment hence resulting in poor performance of a heat exchanger. Thus, in this study, a dust-proof oil cooler has been studied with a unique shape of a 3-dimensional wavy fin since non-louvered fins could have better performance under dusty environment compared to louvered fins. Recently, they have been introduced to commercial and constructional vehicles in Japan. At first numerical analysis has been done to optimize the angle of the wavy fin so that the oil cooler developed can satisfy the target performance. The wavy fin has been then made with roll-forming and roll-pitch stands, and a prototype of an oil cooler with the wavy fin has been finally built with brazing. The performance test showed that the heat release rate of the oil cooler was well beyond the target, 4.94kW and the air-side pressure drop was below the criterion, 0.19kPa. In addition, the results showed that the numerical prediction was effective enough to design the dust-proof oil cooler that satisfies the performance criteria.