S-value of Radioiodine($^{131}I$) in Korean Reference Adult Male

한국 성인남성 표준인을 대상으로 한 방사성옥소($^{131}I$)의 S-value 도출

  • 김정훈 (경희대학교 원자력공학과) ;
  • 임창선 (건양대학교 방사선학과) ;
  • 황주호 (경희대학교 원자력공학과)
  • Published : 2008.03.31

Abstract

In order to better understand the effects of absorbed radioiodine upon Korean reference adult male, a mathematical phantom representation was contrived based on composite data of the physiology of Korean reference adult male. Using this, S-values of radioiodine($^{131}I$) per each organ were calculated. The calculated S-values were compared to the existing data described in the TM-8381 report of ORNLcalculated on the basis of an ICRP-23 reference male. The results indicated that S-values were higher for the phantom based on Korean reference adult male. The results of this study illustrate that, while the bio-chemical constitution of each source and target organ of the torso are important, the relative location of the organs and characteristics of the radionuclides also exert important influences.

한국 성인 남성 표준인(Korean Reference Adult Male)의 기초 자료를 이용하여 수학적 모의 피폭체(Mathematical Phantom)를 제작하였다. 또한 이를 이용하여 방사성옥소($^{131}I$)의 각 장기별 S-value를 산출 하였다. 산출된 S-value는 기존 ICRP-23표준인에 근거하여 산출한 MIRD 5, 및 ORNL-TM 8381자료와 비교해 보았다. 그 결과 S-value는 한국 성인 남성 표준인에 기초한 모의 피폭체가 높은 값을 나타냈다. 이는 몸통이라는 특수한 공간에 위치하게 되는 선원장기(source organ) 및 표적장기(target organ)가 함유하고 있는 구성물질도 중요하지만 그에 못지않게 이들이 차지하고 있는 위치 및 방사성핵종의 특성 또한 중요하게 작용한다는 것을 알 수 있었다.