DOI QR코드

DOI QR Code

Performance Evaluation of Decentralized Control Algorithm of a Full-scale 5-story Structure Installed with Semi-active MR Damper Excited by Seismic Load

준능동 MR감쇠기가 설치된 실물크기 구조물의 분산제어 알고리즘 성능평가

  • Published : 2008.02.20

Abstract

In this study, seismic response control performance of decentralized response-dependent MR damper which generates the control force using only the response of damper-installed floor, was experimentally investigated through the tests of a full-scale structure installed with large MR dampers. The performance of the decentralized control algorithm was compared to those of the centralized ones such as Lyapunov, modulated homogeneous friction, and clipped-optimal control. Hybrid mass damper were controlled to induce seismic response of the full-scale structure under El Centro earthquake. Experimental results indicated that the proposed decentralized MR damper provided superior or equivalent performance to centralized one in spite of using damper-installed floor response for calculating input voltage to MR damper.

Keywords

References

  1. Casciati, F., Magonette, G. and Marazzi, F., 2006, 'Technology of Semiactive Devices and Applications in Vibration Mitigation', John Wiley & Sons
  2. Spencer Jr, B. F. and Sain, M. K., 1997, 'Controlling Buildings : A New Frontier in Feedback', IEEE Control Systems Magazine: Special Issue on Emerging Technologies (Tariq Samad Guest Ed.), Vol. 17, No. 6, pp. 19-35
  3. Dyke, S. J. and Spencer Jr, B. F., 1996, 'Seismic Response Control Using Multiple MR Dampers', Proceedings of the 2nd Intl. Workshop on Struc. Control, Hong Kong, pp. 163-173
  4. Dyke, S. J., Spencer Jr, B. F., Sain, M. K. and Carlson, J. D., 1998, 'An Experimental Study of MR Dampers for Seismic Protection', Smart Materials and Structures: Special Issue on Large Civil Structures, Vol. 7, pp. 693-703
  5. Yang, G., Spencer Jr, B. F., Jung, H. J., Carlson, J. D., 2004, 'Dynamic Modeling of Large-scale Magnetorheological Damper Systems for Civil Engineering Applications', Journal of Engineering Mechanics, Vol. 130, No. 9, pp. 1107-1114 https://doi.org/10.1061/(ASCE)0733-9399(2004)130:9(1107)
  6. Jansen, L. M. and Dyke, S. J., 2000, 'Semiactive Control Strategies for MR Dampers : Comparative Study', Journal of Engineering Mechanics, ASCE, Vol. 126, No. 8, pp. 795-803 https://doi.org/10.1061/(ASCE)0733-9399(2000)126:8(795)
  7. Inaudi, J. A., 1997, 'Modulated Homogeneous Friction : A Semi-active Damping Strategy', Earthquake Engineering and Structural Dynamics, Vol. 26, No. 3, p. 361 https://doi.org/10.1002/(SICI)1096-9845(199703)26:3<361::AID-EQE648>3.0.CO;2-M
  8. Lee, S. H., Park, E., Lee, S. K., Yu, E., Youn, K. J., Min, K. W., Min, J. K. and Kim, Y. C., 2006, 'Forced Vibration Test of a Real-scale Structure and Design of HMD Controllers for Simulating Earthquake Response', Transaction of Earthquake Engineeing Society of Korea, Vol. 10, No. 6, pp. 103-114 https://doi.org/10.5000/EESK.2006.10.6.103
  9. Youn, K. J., Min, K. W. and Lee, S. H., 2007, 'Seismic Response Control of Structures Using Decentralized Response-dependent MR Dampers', Transaction of Computational Structural Engineering Institute of Korea, Vol. 20, No. 6, pp. 761-767
  10. Leitmann, G., 1994, 'Semiactive Control for Vibration Attenuation', Journal of Intelligent Material Systems and Structures, Vol. 5, September, pp. 841-846 https://doi.org/10.1177/1045389X9400500616
  11. Lee, S. H., Park, J. H., Youn, K. J. and Min, K. W., 2007, 'Response Spectra of Structure Installed Frictional Damping System', Transactions of the Korean Society for Noise and Vibration Engineering, Vol. 17, No. 1, pp. 88-94 https://doi.org/10.5050/KSNVN.2007.17.1.088

Cited by

  1. Real-time Semi-active Vibration Control in Cable-stayed Bridges by Shear-type MR damper and Clipped-optimal Control Algorithm vol.20, pp.2, 2016, https://doi.org/10.5000/EESK.2016.20.2.113