References
- D. A. Stein, S. Lee, and K. B. Raskin, 'Compartment syndrome of the hand caused by computed tomography contrast infiltration,' Orthopedics., vol. 26, no. 3, pp.333-334, 2003
- D. C. Kweon, T. H. Kim, S. H. Yang, B. G. Yoo, M. G. Kim, and P. Park, 'Subcutaneous injection contrast media extravasation: 3D CT appearance,' Korean J. Med. Phys., vol. 16, no. 1, pp.47-51, 2005
- R. C. Nelson, F. A. Anderson, B. A. Birnbaum, J. L. Chezmar, and S. N. Glick, 'Contrast media extravasation during dynamic CT: detection with an extravasation detection accessory,' Radiology., vol. 209, pp. 837-843, 1998 https://doi.org/10.1148/radiology.209.3.9844684
- J. G. Amaral, J. Traubici, G. BenDavid, G. Reintamm, and A. Daneman, 'Safety of power injector use in children as measured by incidence of extravasation,' Am. J. Roentgenol., vol. 187, pp.580-583, 2006 https://doi.org/10.2214/AJR.05.0667
- D. C. Kweon, S. H. Jeong, T. H. Kim, J. G. Kim, andP. Park, 'The development of extravasation detection accessory system for the preventive contrast media extravasation in the computed tomography: a preliminary report,' Korean J. Med. Phys., vol. 17, no. 1, pp.32-39, 2006
- W. H. Bush, and D. P. Swanson, 'Acute reaction to intravascular contrast media. types, risk factors, recognition, and specific treatment,' Am. J. Roentgenol., vol. 157, pp.1153-1161, 1991 https://doi.org/10.2214/ajr.157.6.1950858
- R. K. Daniel, and H. B. William, 'The free transfer of skin flaps by microvascular anastomoses. An experimental study and a reappraisal,' Plast. Reconstr. Surg., vol. 52, no. 1, pp.16-31, 1973 https://doi.org/10.1097/00006534-197307000-00003
- S. H. Kim, J. H. Park, Y. I. Kim, C. W. Kim, and M. C. Han, 'Experimental tissue damage after subcutaneous injection of water-soluble contrast media,' Invest. Radiol., vol. 25, no. 2, pp.171-183, 1989
- S. L. Sistrom, S. B. Gay, and L. Peffley, 'Extravsastion of iopamidol and iohexhol during contrast-enhancement CT: report of 28 cases,' Radiology., vol. 180, pp.707-710, 1991 https://doi.org/10.1148/radiology.180.3.1871281
- M. P. Federle, P. J. Chang, S. Confer, and B.Ozgun, 'Frequency and effects of extravasation of ionic and nonionic CT contrast media during rapid bolus injection,' Radiology., vol. 637, pp.637-640, 1998
- J. E. Jacobs, B. A. Birnbaum, and C. P. Langlotz, 'Contrast media reactions and extravasation: relationship to intravenous injection rates,' Radiology., vol. 209, pp.11-416, 1998
- S. T. Cochran, K. Bomyea, and J. W. Sayre, 'Trends in adverse events after IV administration of contrast media,' Am. J. Roentgenol., vol, 176, no. 6, pp.1385-1388, 2001 https://doi.org/10.2214/ajr.176.6.1761385
- S. G. Miles, J. F. Rasmussen, and T. Litwiller, 'Safe use of an intraveous power injector for CT: experience and protocol,' Radiology., vol. 190, pp.69-70, 1990
- E. Vandeweyer, O. Heymans, and R. Deraernaecker, 'Extravasation injuries and emergency suction as treatment,' Plast. Reconstr. Surg., vol. 105, pp.109-110, 2000 https://doi.org/10.1097/00006534-200001000-00019
- B. A. Birnbaum, R. C. Nelson, F. A. Anderson, J. L. Chezmar, and S. N. Glick, 'Extravasation detection accessory: clinical evaluation in 500 patients,' Radiology., vol. 212, pp.431-438, 1999 https://doi.org/10.1148/radiology.212.2.r99au14431
- M. F. Bellin, J. A. Jakobsen, I. Tornassin, H. S. Thomsen, S. K. Morcos, et al. 'Contrast Media Safety Committee Of The European Society Of Urogenital Radiology,' Eur. Radiol., vol. 12, no. 11, pp.2807-2812, 2002
- D. C. Kweon, S. H. Jeong, S. H. Yang, M. S. Cho, K. J. Jang, S. G. Kim, B. G. Yoo, and J. S. Lee, 'An Experimental Study for the Preventive of CT Contrast Media Extravasation with Extravasation Detection Accessory System in Femoral Vein of Rabbit,' Korean J. Med. Phys., vol. 17, no. 4, pp.238-245, 2006