DOI QR코드

DOI QR Code

Load Following Control of Pressurized Water Reactor

P.W.R. 원자로의 부하추종제어

  • Published : 2008.03.01

Abstract

This paper presents a self-tuning controller for pressurized water reactor (P.W.R.). This self-tuning controller includes two substantial steps, such as parameter identification and control-law building in each cycle. Extended least square algorithm is used for parameter identification, Kalman filter is used for state estimation, and discrete Riccati equation is used for optimal control. Effectiveness of this algorithm is shown through computer simulation and sensitivity analysis.

Keywords

References

  1. K. J. Astrom, "Theory and applications of adaptive control-A servey," Automatica, vol. 19, no. 5, pp. 477-486, 1983
  2. L. F. Miller et al., "Nuclear reactor control systems with sensor failure," Nuclear Technology, vol. 36, pp. 93-195, 1977 https://doi.org/10.13182/NT77-A31963
  3. W. H. Press et al., "Numerical recipes in C," Cambridge University Press, 1988
  4. Y. T. Tsay and L. S. Shieh, "State-space approach for self-tuning feedback control with pole assignment," IEE Proc., vol. 128, no. 3, pp. 93-101, 1981
  5. D. E. Kirk, Optimal Control Theory: an Introduction, Prentice- Hall, 1970
  6. L. S. Shieh, C. T. Wang, and Y. T. Tsay, "Fast suboptimal statespace self-tuner for linear stochastic multivariable systems," IEE proc, vol. 130, no. 4, pp. 143-154, 1983