Finger Doses Received during $^{99m}Tc$ Injections Calculated with GEANT4

GEANT4를 이용한 $^{99m}Tc$ 주입시 손가락 선량계산

  • Han, Dong-Hyun (Department of Radiation Science & Technology, Chonbuk National University) ;
  • Kang, Sang-Koo (Department of Radiation Science & Technology, Chonbuk National University) ;
  • Kim, Chong-Yeal (Department of Radiation Science & Technology, Chonbuk National University)
  • 한동현 (전북대학교 방사선과학기술학과) ;
  • 강상구 (전북대학교 방사선과학기술학과) ;
  • 김종일 (전북대학교 방사선과학기술학과)
  • Published : 2008.03.31

Abstract

To estimate the finger dose absorbed by $^{99m}Tc$ injection, simulations are carried out to calculate the dose equivalent of each finger per second with radioactivity of 370 MBq, based on the GEANT4 simulator. For the $^{99m}Tc$ source of the volume of 0.4mL and the radioactivity of 370 MBq, we obtained the dose equivalent of the right thumb ($0.29\;{\mu}Sv{\cdot}sec^{-1}$), the right index finger ($1.19\;{\mu}Sv{\cdot}sec^{-1}$), the right middle finger ($1.07\;{\mu}Sv{\cdot}sec^{-1}$), the left thumb ($4.36\;{\mu}Sv{\cdot}sec^{-1}$), and the left index finger ($3.37\;{\mu}Sv{\cdot}sec^{-1}$), respectively. This simulation results may serve as a useful data in the prediction of finger dose absorbed by $^{99m}Tc$ injection.

[ $^{99m}Tc$ ]를 주사할 때 시술자의 손가락에 흡수되는 방사선량을 예측하기 위해, GEANT4를 이용하여 초당 370 MBq의 방사능량을 가지는 0.4 mL 체적의 $^{99m}Tc$ 선원을 대상으로 각 손가락에 대한 등가선량을 구하였다. 시뮬레이션 결과, 오른손 엄지($0.29\;{\mu}Sv{\cdot}sec^{-1}$), 검지($1.19\;{\mu}Sv{\cdot}sec^{-1}$), 중지($1.07\;{\mu}Sv{\cdot}sec^{-1}$), 왼손 엄지($4.36\;{\mu}Sv{\cdot}sec^{-1}$), 검지($3.37\;{\mu}Sv{\cdot}sec^{-1}$)의 등가선량을 얻을 수 있었다. 이와 같은 계산 결과는 $^{99m}$Tc 주입시 시술자의 손가락에 흡수되는 선량을 예측할 수 있는 유용한 기초자료로 활용될 수 있을 것이다.

Keywords

References

  1. 추성실. 방사선의 의학적 이용에 따른 방사선 안전관리 현황, 방사선방어학회지. 1990;15(1):39-46
  2. 박영선, 유장수, 김동윤. 의료방사선 관리학. 서울;신광출판사, 1999:139-148
  3. ICRP. General Principle of Monitoring for Radiological Protection, ICRP Publication 35, pergamon Press, Oxford, 1982
  4. 김광표, 이원근. 감마선에 의한 말단팬텀에서의 선량분포 연구. Journal of industrial Liaison Research Institute, 1995;1:151-156
  5. Chruscielewski W, Olszewski J, Hankowski J, Cygan M. Hand exposure in nuclear medicine workers. Radiation protection dosimetry. 2002:101(1);222-232
  6. Hilditch TE, Elliott AT, Anstee DE, Murray T. Fifteen years of radiological protection experience in a regional radiopharmacy. Health physics. 1990:59(1);109-116 https://doi.org/10.1097/00004032-199007000-00013
  7. Gauri S. Pant, Sanjay K. Sharma, Gauri k, Rath. Finger Doses for Staff Handling Radiopharmaceuticals in Nuclear Medicine. Journal of Nuclear Medicine Technology. 2006:34(3):169-173
  8. Fukunaga Y, Matsuoka N, Mae T, Kouno T. Trial manufacture of a plunger to reduce finger exposure [in Japanese]. Kaku Igaku. 2001:38(2);113-123
  9. 과기부고시 1992-15."개인방사선 피폭선량평가에 의한 기술기준" 과학기술부. 1992
  10. 과기부고시 2003-6."개인 피폭방사선량의 평가 및 관리에 관한 규정" 과학기술부. 2003
  11. Cosmo G. Software process in Geant4. In, Computing in High Energy and Nuclear Physics. Beijing. China. 2001:469- 472
  12. GEANT4 Homepage, http://geant4.cern.ch
  13. Geant4 User's Documents, http://geant4.cern.ch/support/userdocuments.shtml
  14. Kang SK, Kim CY. Structure and Application of GEANT4 in Radiation Science. Journal of Radiation Industry. 2007:1(1);39-46