Structural Behavior of RC Beam Strengthened with External Tendons Using Lifting Hole Anchorage System

인양홀을 이용한 외부 강선 보강 철근 콘크리트 보의 거동 특성

  • 이석훈 (성균관대학교 건설환경시스템공학과) ;
  • 홍성남 (성균관대학교 건설환경시스템공학과) ;
  • 한경봉 (성균관대학교 건설환경시스템공학과) ;
  • 박선규 (성균관대학교 건설환경시스템공학과)
  • Received : 2007.08.13
  • Accepted : 2008.02.05
  • Published : 2008.07.30

Abstract

The strengthening in terms of efficiency, easy, economics is very popular method when it is applied to a damaged structures. The purpose of this study develops anchorage system that supports enough strengthening effect without any damage. In addition it is checked whether the method can be conveniently applied to structures. To verify strengthening effect a flexural experiments were performed. Four concrete beams were constructed and tested. Deflections, strains and modes of failure were recorded to examine strengthen of beams. Comparing crack load of each experimental data, yielding load, ultimate load, ductility index, and tendon stress were analyzed.

인양홀을 이용한 정착장치는 손상된 구조물에 내하력을 증가시키기 위해 사용되어지며, 시공이 간편하고 보강효율이 좋은 경제적인 방법이다. 본 논문에서는 구조물에 손상을 입히지 않으면서 충분한 보강효과를 가져 올 수 있는 인양홀 이용 정착장치를 선정하여 그에 대한 적용 가능성을 연구하였다. 실무에서 시공빈도가 높은 인양홀 이용 단부 정착 장치가 적용된 3개의 실험체를 제작하였고, 이에 대한 휨 실험을 수행하여 처짐, 변형률 및 파괴양상을 분석하였다. 인양홀 이용 정착장치가 구비된 철근 콘크리트 보의 보강 성능을 실험적으로 규명하기 위하여 각 실험체의 균열하중, 항복하중, 극한하중, 강선의 응력 증가량, 처짐 및 연성 등을 비교 분석하였다.

Keywords

References

  1. 건설교통부, 콘코리트구조설계기준, 2003
  2. 김기봉, 정영수, 최혁주, 강보순, "외부 후긴장으로 보강한 합성보에 대한 실험적 연구," 한국강구조학회논문집, 제10권 제4호, 1999, pp. 701-708
  3. 박승범, 홍석주, "정착방법에 따른 외부 프리스트레스트 도입공법의 보강성능평가," 한국콘크리트학회 봄 학술발표회 논문집, 2001, pp. 279-284
  4. 오병환, 유성원, 조윤구, 서정인, "강선 형상과 편향부 수에 따른 외부 강선을 가진 PSC 보의 휨거동 실험," 대한토목학회 논문집, Vol.23 No.4A, 2003, pp. 795-804
  5. 유성원, 홍경욱, "부분부착 강선 모델을 이용한 외부 프리스트레스트 콘크리트 보의 휨해석 및 휨성능개선," 대한토목학회 논문집, Vol.20 No.5-A, 2000, pp. 813-821
  6. 윤영묵, 최명석 "포스트-텐션 부재의 정착부에 관한 AASHTO 시방규정의 평가," 대한토목학회 1999년도 학술발표회 논문집(1), 1999
  7. 이상열, 이재형, 한만엽, "외부프리스트레스 보강 공법에 사용되는 인장형 단부 브라켓의 개발연구," 대한토목학회 논문집, 제21권 제4호, 2001, pp. 611-618
  8. ACI Committee 318, "Building Code Requirement for Reinforced Concrete", ACI-318-05, American Concrete Institute, Detroit, 2005
  9. Ahmed Ghallab and A.W. Beeby "Factors affecting the external prestressing stress in externally strengthened prestressed concrete beams," Cement and Concrete Composites, Volume 27, Issues 9-10, October-November 2005, pp. 945-957 https://doi.org/10.1016/j.cemconcomp.2005.05.003
  10. Angel C. Aparicio, Gonzalo Ramos, "Flexural Strength of Externally Prestressed Concrete Bridges," ACI Structural Journal, Vol. 93, No. 5, 1996, pp. 512-522
  11. European Committee for Standardization, Eurocode 2 Design of Concrete Structures, European Committee for Standardization, Brussels, 2002
  12. Kiang-Hwee Tan, Chee-Khoon Ng, "Effects of Deviators and Tendon Configuration on Behavior of Externally Prestressed Beams," ACI Structural Journal, Vol. 94, No. 1, 1997, pp. 13-22
  13. Naaman, A. E., "Ductility of Reinforced and Prestressed and Prestressed Concrete Flexural Members", PCI Journal, Mar.-Apr., 1990
  14. N. F. Grace, A. K. Soliman, G. Abdel-Sayed and K. R. Saleh, "Behavior and Ductility of Simple AND Continuous FRP Reinforced Beams." Journal of Composites for Construction (ASCE), Vol. 2 No. 4 November, 1998, pp. 186-194 https://doi.org/10.1061/(ASCE)1090-0268(1998)2:4(186)